| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹12.5 L+₹52,448.90 (4.38%)Rejected-AOC MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L2 | Rejected-AOC Other than L1 bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
26 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF SEWAGE LINE AND OTHER MISC CONNECTED WORKS UNDER AGE BR-IV OF GE (S) JAIPUR
2024_MES_648263_1
GE(S)/J-72P/2023-24 8875/E8
Open Tender
Civil Works
Item Rate
210 days
GE(S) Jaipur
Class E and category a(ii)
9 documents required · 9 mandatory
₹500
GE(S) Jaipur
₹30,000
Yes
24 Jul 2024
28 Mar 2024
3 May 2024
28 Mar 2024
26 Apr 2024
11 Apr 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5 m depth and getting out in soft /loose soil etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3.0 m depth and getting out in soft /loose soil etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and exceeding 3 m but not exceeding 4.50 m depth and getting out in soft /loose soil etc complete all as specified and directed.
Use and waste of timbering exc 3.0 m and n exc 5.0 mtr depth as planking and strutting for excavations in trenches in shafts, wells, cesspits, manholes and pier holes as may be necessary and fixing and removal complete all as specified and directed.
Removing excavated soil n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed
Demolition and breaking up drain pipes salt glazed ware set in CM 150 mm bore pipe complete all as specified and directed.
Demolition and breaking up drain pipes salt glazed ware set in CM 200 mm bore pipe complete all as specified and directed.
Supply and laying DWC Pipes (Double wall corrugated) of class SN-4, IS-16098 (Pt-II) of size internal dia of 150mm laid in trenches and jointed complete with coupler, bends, Tee, Reducers etc complete all as specified and as directed. Make:- Ultra Plus DWC PE Pipe of supreme/Corfit of prince/D-Rex DWC of Astral
Supply and laying DWC Pipes (Double wall corrugated) of class SN-4, IS-16098 (Pt-II) of size internal dia of 200mm laid in trenches and jointed complete with coupler, bends, Tee, Reducers etc complete all as specified and as directed. Make:- Ultra Plus DWC PE Pipe of supreme/Corfit of prince/D-Rex DWC of Astral
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed.
S&F reinforced concrete pipes, class NP-2, laid and jointed with collars of150 mm bore of pipe complete all as specified and directed.
S & F in repair 150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor including bends ( Joining to be done with solvent cement ) including PVC brackets and PCC bed of 1:3:6 type C2 concrete packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using old size sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in roof kerbs or mud stops rounded or chamfered on edges complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc),chullah hoods, chajjas, water troughs,mangers, shelves and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.
Mild Steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 200 mm internal dia of pipe complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15 cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate, 75 mm thick in plinth protection laid in panels and finished even and fair including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in quoted rate for concrete in plinth protection.
M & L for ready mix cold bitumen for repair in road cutting including cleaning of surface, compaction and laying of emulsion compcted thickness 30 mm complete all as specified and directed.
M&L for rubber moulded chequered cement concrete tiles 20 cm x 20 cm x 22 to 25 mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and no pigments over and including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness, laid dry or laid dry and pointed in any mortor in floor, apron etc complete all as specified and directed
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over and including 20mm thick (compacted thickeness) sand bed complete all as specified and directed.
All as per item No, 29.00 above but except tiles complete all as specified and directed
Scooping and taking out sludge and foreign material from manholes any size of depth n. exc 1.5 metre below GL. and including removing and re-fixing of manholes covers, etc and appliances required for safe disposal of sludge and foreign material by carrying out the same covered van/trolley out side defence land and it should be disposed off at distance not less than 1.5 KM away at such place which is not detrimental to public health and complete all as specified and directed. Note :- Net volume of internal size of each septic tank, soakage well, up to the depth of water from bottom shall be measured for payment purpose including dewatering and removing dry/wet sludge etc complete.
All as per serial item No. 31.00 here-in-before but for manholes any size of depth exc 1.5 metre but n.exc 3.0 metre complete all as specified and directed.
All as per serial item No. 31.00 here-in-before but for manholes any size of depth exc 3.0 metre but n.exc 4.5 metre complete all as specified and directed.
M & L for precast RCC soakage well (700-750 mm dia & 40mm thick wall 250 mm height each) upto 8.00 m effective depth including excavation in any type of soil complete all as specified and as per manufacturer's instruction and as directed. complete all as specified and directed.
M/S HARI CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .