Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 25 KARAMBHUMI SAMASGARH ROAD SAMAGARH BHOPAL MADHYA PRADESH 462044 | BHOPAL | MADHYA PRADESH | 462044 | Admitted-Finance |
| 2 | Admitted-Finance 1442 WAZIR NAGAR KOTLA MUBARAKPUR NEW DELHI DELHI 110003 | NEW DELHI | DELHI | 110003 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Lack of Experience as desired |
Tender Value
₹32.4 L
EMD Value
₹65,000
Closing Date
5 Mar 2025, 3:00 pmClosed
The Director, ICAR-CRRI CUTTACK
ICAR-CRRI CUTTACK-753006
Renovation work of existing Green-houses Chamber at ICAR-CRRI Cuttack
2025_DARE_851260_1
48/Civil/Tech/2024-25
Open Tender
Civil Works
Works
30 days
ICAR-CRRI CUTTACK
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹65,000
Yes
13 Mar 2025
28 Feb 2025
6 Mar 2025
28 Feb 2025
5 Mar 2025
28 Feb 2025
Amount
Renovation work of existing Green-houses Chamber” at ICAR-NRRI Cuttack
The transgenic green house of size 32’ x 25’x13’:10’ (LxWxH c:s) with four chamber size of 12.5’x12.5’and corridor size of 25’ x6’ requires the renovation of HMI Control Panel for 4 Chamber Control which has Control system which can monitor and Temperature, Humidity, and light, it maintains chamber climate by optimum controlling of chamber equipment’s like cooling fan, heaters, ventilation, internal screen lights etc. It is also including switching system for operating chamber equipment with suitable relays, contractors, and safety devices. The specific conditions and requirements for this renovation of HMI control panel is as follows, • 7”/10” HMI with Feather buttons, Data logging Feature, PLC system with inbuilt analog module for sensor connection, Multi- Set point programming, Multistage cooling /heating control • Sensor for Temperature & RH: Range: Range 0-50 °C and 0- 100%., Type: 4- 20 mA, Sensor for Light Sensor: Range: 0- 20 KLUX, Type: 4-20 mA. OUTPUTS: • Light Control: Control Cycle: ON/ OFF, multiple stages, Accuracy: ±10 sec/day, Temperature controller: Cooling Control: • Control type: PID, Multiple stage control, Temp. Range: 0.1 to 59.9°C., Accuracy: ±1°C., Hysteresis: 0.4°C Heaters Control: • Control Type: ON/OFF, Multiple stages, Temp. Range: 0.1 to 59.9°C., Hysteresis: 0.4°C Humidity Control • Control type: ON/OFF, Range: 50% to 90%. (Real RH: ±2%. ±1 digit (at 45%). Temperature Range: Temperature range of 25ºC to 40 ºC ± 1ºC.
a. The Lighting system also requires renovation with 8 Light (2 Light Each Chamber) 250-watt LED Light source with following specifications, • Light Source : LED • Spectrum : Full Spectrum • Measured PPF : 545 μmol/s • Input Power : 386W • LED Efficacy : 2.8umol/J • Input Voltage : 100-220V AC • Fixture Dimensions : 615 X 180 X 80 (L x B x H) • Recommended Height : 18" above Grow Bed • Thermal Design : Passive • Dimming : 1-10V • Light Spread : 120*/45* • Expected Lifetime : L90>50,000Hrs • Power Factor :>0.9 b. The corridor also requires the LED 20-watt Light for corridor
Cooling System for 4 Chamber: a. Air conditioner units will be provided, which are responsible to maintain the required temperature range 25ºC to 40ºC ± 1ºC (2-ton AC - qty 8)2 AC for Each 4 Chamber b. 2 Tonn AC Repairing qty 4
Cladding a. Complete Cladding Change of Existing Structure size 32’ x25’ 6mm Polycarbonate Sheet PC sheet. Aluminum Section, Plate Rubber with other fitting accessories, change for chamber. b. External Shading: Green shading net change for roof fix. c. False Ceiling for 4 Chamber (Each Chamber size 12.5’ x12.5’): False ceiling on roof Existing frame work, made of Anodized/ powder coated Aluminum T/Angle sections suspended from roof structure. d. Gutter: 25’ Long, 248mm wide and 1.5mm thick molding hot galvanized steel plate with fitting accessories qty 2set
Ultra fogging system qty 4 (1 set each chamber) Ultra Fogging system by micro-Fogger 15 microns Ultrafine fogging system with SS nozzles, hi - pressure pump, screen filter, polymer water tank and accessories. RO System for micro fogging & ultra-fogging
Door &Ventilation a. Door Repairing. Qty 7(4 Sliding door & 3 Openable door) b. Ventilation: Sliding Window type ventilation size 2’x2’ (HxW) made By PC (Polycarbonate sheet) sheet with sliding c. Painting: Wall Painting work for existing wall
Heater 2.4 kw (1 Heater for Each Control Chamber) Electric heat blower system 2.4 KW. Complete uniform heat circulation system has been given in this heat, so that the heat can be blown in the complete area. Qty-4
Electric wiring for entire facility: All wires will be of copper and desired load and switches (Anchor/Hovels) imported make, extra switches also provided as standby, each feature has own electric line MCB (Anchor/Hovels) and will be under ground in PVC pipe complete set with A grade work. complete set.
Saveer Biotech Limited (BID ID -3182103)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .