Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹19.4 L+₹1.2 L (6.33%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹19.7 L+₹1.5 L (8.30%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹20.0 L+₹1.8 L (9.69%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | L5₹20.4 L+₹2.1 L (11.7%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹24.6 L
EMD Value
₹49,300
Closing Date
8 Jun 2020, 6:00 pmClosed
GE Nagrota
Office complex of GE Nagrota
Provn of retaining wall, drainage and culvert at 4 ASD, fly proofing tiling and drain at Avn Sqn and internal wiring / rewiring of certain bldgs at Sitni enclave and section hospital at Nagrota under GE Noagrota.
2020_MES_343951_1
GEN-03/2020-21
Open Tender
Civil Works
Item Rate
180 days
Nagrota
As per NIT
8 documents required · 8 mandatory
₹500
GE Nagrota
₹49,300
Yes
2 Jul 2020
11 May 2020
13 Jun 2020
11 May 2020
8 Jun 2020
25 May 2020
12 May 2020 - 18 May 2020
Amount
Schedule 'A' Part-I (B&R and Misc Work)
Excavating over area n. exc 1.5m deep and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil, complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point, complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filing and and mass concreate, complete all as specified and directed.
M&L for RCC, M-25, design mix (using 20 mm graded crushed stone aggregates) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc and mass, concrete all as specified and directed.
M & L for RCC, M-25, design mix (using 20 mm graded crushed stone aggregates) as in walls, retaining walls, basement walls, ballast walls and the like any thickness above top of footings including attached pillasters and buttresses, complete all as specified and directed.
Mild Steel TMT bars 10 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
Formwork to sides of concrete foundations, bases for column beams, plinth beams and soffits of foundation and pllinth beams and similar work (rough finished), complete all as specified and directed.
Formwork to faces of concrete walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc vertica or to batter for flat rough finished surfaces, complete all as specified and directed.
Surface dressing in any type of soil n.exc 15 cm deep watering and removing surplus soil a distance n.exc 50m and making good surface, complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil, complete all as specified and directed.
M & L for PCC 1:2:4 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filing and and mass concreate, complete all as specified and directed.
M&L for PCC, 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span , cills , steps , seismic, and other similar bands , plinth couses, sring courses, lacing course, parapets and railing upto 60 cm in height, coping, kneelars, apex stones bed plates , kerb etc, complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement, complete all as specified and directed.
M & L for PCC 1:3:6, Type- C-2 (using 20mm graded crushed stone aggregate) as in surface channels & drains, complete all as specified and directed.
M&L for 600mm bore dia reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars, complete all as specified and directed by Engr-in-charge.
M&L for concrete bed to drain pipes of bore 600mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and supports, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of cement base paint, complete all as specified and directed.
M&L for hard core of broken bricks boulder n exc 63 mm, deposited, spread and levelled in layers n exe 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for 100 mm thick plain cement concrete, 1:4:8, type D-2 ( using 40 mm graded crushed stone aggregate ) as in sub base and paving, complete all as specified and as directed.
M&L for 100 mm thick plain cement concrete, 1:2:4, type B-2 ( using 40 mm graded crushed stone aggregate ) as in sub base and paving, complete all as specified and as directed.
S & F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm dia and fixed with tinned tacks or galvanised mild steel staples, complete all as specified and directed.
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary agusset plate, riveting etc. n. exc 10kg each brackets conforming to FE 290 Grade E-165, complete all as specified and directed.
Mild steel Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
Prepration of new or previously steel surfaces any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M & L for 10 mm thick Vitrified Ceramic tiles, Light shade, (square/rectangle) Polished area of each tile exceeding 0.36 sqm but n exc 0.42 sqm, in verticle surfaces like skirting, Dado set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over and including 15mm thick bedding layer of mortar for laying floor finishes in CM 1:6 including dismantling of old existing tiles, complete all as specified and directed.
M & L for Glazed ceramic coloured printed tiles (first quality) of size 350 mm x 250 mm x 7 mm/450 mm x 350 mm x 7 mm thick as in vertical surface, dado/skirting, over and including 10 mm thick screed bed in CM 1:4 including dismantling of old existing tiles, complete all as specified and directed.
M&L for 300mm bore dia reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars, complete all as specified and directed by Engr-in-charge.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4, complete all as specified and directed.
Schedule 'A' Part-II (Internal Electrification)
Taking down carefully aluminium conductor point wiring (light fan, socket and power) complete with fittings such as switches, sockets, lamps holder, utility light fitting, fan regulator etc and making good disturbed surface of walls and floors etc. and keeping in safe custody for taking credit, complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fan any sweep, removing blades, cleaning the fan completly for dust and dirt and hanging the same back to its original position including connecting the 3 core flexible copper wire to ceiing rose etc after the completion the point wiring including replacement old unservicable fan hook, rubber pad, nut bolts and washers etc, complete all as specified and directed by Engineer in charge.
Taking down existing energy meters, keeping aside safely & refixing the same in its original position after making functional & after completion of point wiring/sub main wiring, complete, all as specified and directed by Engr-In-Charge. Note:- Small items required for fixing the electric energy meter at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
Taking down existing electric water heater, keeping aside safely & refixing the same in its original position after servicing of the whole geyser/making functional and afer completion f wiring work, complete all as specified and directed by Engr-In-Charge. Note:- If any part found unserviceable during the refixing of water heater at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
Point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following;-
One light point controlled by one switch 5 Amp.
One ceiling fan/exhaust fan point controlled by one switch 5Amp
One socket out let 5Amp controlled by one switch on same board.
One socket out let 5 Amp controlled by one switch on independent board.
One bell point 5 Amp controlled by one bell push on independent board.
All as per item No 2.05 here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
S & F Switch piano flush type 5 Amps single pole one way, complete all as specified and directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and directed.
S & F Switch socket combination 2 in 1 5 pin 5 /15 Amps flush type, complete all as specified and directed.
S & F Ceiling rose surface bakalite, 3 phase complete PVC/polycarbonate isolated body, complete all as specified and directed.
S & F Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required, complete all as specified and directed
S&F Bell push piano flush type single pole one way 5 Amps, complete all as specified and directed.
S & F Electric bell ding dong 230 volt AC, complete all as specified and directed.
S & F Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, Cat part No. BLRB DB 118 ( for batten fitting) & Cat part no. BLRB18W CW LED (for LED 18 watt ) of Bajaj or equivalent in approved make, complete all as specified and directed.
S & F batten integrated LED channel of 5W, 230 V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, power factor not less than 0.9 as per Cat No BCLSB 05 WH of Bajaj or equivalent in approved make, complete all as specified and directed.
S & F decorative wall mounted luminair with & including 9 watt LED lamp complete as per Cat No LHFHCHE1TL1W020 of Havells or equivalent in approved make, complete all as specified and directed.
S&F LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz, complete all as specified and directed.
S&F Lamp holder PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
S& F LED bulb 7 watt , complete all as specified and directed.
Sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
S & F in repair Sheet metal enclosure double door for distribution board factory made for MCB DB load link TPN 4 way suitable for MCCB as incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification, complete all as specified and directed.
S & F MCB DP 63 Amps 10 KA 230 volts "C" series, complete all as specified and directed.
S & F MCB single pole 6 to 30 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
S & F MCB single pole 40 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
S&F in repairs of MCCB 125 Amps, 4 pole, 415 Volts, 16 KA, with adjustable thermal and adjustable magnetic settings as per existing at site, complete all as specified and directed by Engr-in-Charge.
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sq mm as earth continuity conductor connected to commen earth and earth dolly including taking down old cable, complete all as specified and directed
S & F MCB SPN 32/40 Amps, 10 KA, 230 volts 'C' series, complete all as specified and directed.
S & F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB SP 32/40 Amps, complete all as specified and directed.
S&F sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 sqmm as earth continuity conductor connected to common earth and earth dolly including taking down old cable, complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - III) Amount of Rs. 11409.00 during AOC Note:- Tenderers shall not quote for this Schedule
M/S MANISHA BUILDERS
MAMTA ENTERPRISES
Kalsi Engineers and contractors
M/s Pee Kay Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .