Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹47.3 L+₹2.7 L (6.04%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹50.1 L+₹5.4 L (12.2%)Admitted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L3 | Admitted-Finance | |
| 4 | L4₹50.4 L+₹5.8 L (12.9%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹50.9 L+₹6.3 L (14.1%)Admitted-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MV Engineers And Contractors L6 | mayur enterprises L3 | Vijay Electricals L7 | Rajindera Enterprises L2 | Buddham Builders L1 | M/s Adhikari construction co. L5 | DS CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge. | 2,805 | Cum | 79 ₹2,21,595 | 90 ₹2,52,450 | 79 ₹2,21,595 | 100 ₹2,80,500 | 60 ₹1,68,300 | 99 ₹2,77,695 | 50 ₹1,40,250 Lowest |
| 2.00 | Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. | 1,504 | Cum | 15 ₹22,560 Lowest | 19 ₹28,576 | 29 ₹43,616 | 20 ₹30,080 | 25 ₹37,600 | 19 ₹28,576 | 25 ₹37,600 |
| 3.00 | Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. | 1,301 | Cum | 15 ₹19,515 Lowest | 19 ₹24,719 | 29 ₹37,729 | 20 ₹26,020 | 30 ₹39,030 | 29 ₹37,729 | 25 ₹32,525 |
| 4.00 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. | 770 | Cum | 250 ₹1,92,500 | 200 ₹1,54,000 Lowest | 250 ₹1,92,500 | 300 ₹2,31,000 | 340 ₹2,61,800 | 299 ₹2,30,230 | 200 ₹1,54,000 Lowest |
| 5.00 | S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge. | 63,228 | Each | 3 ₹1,89,684 | 3 ₹1,89,684 | 2 ₹1,26,456 Lowest | 4 ₹2,52,912 | 2.5 ₹1,58,070 | 2.99 ₹1,89,051.72 | 2 ₹1,26,456 Lowest |
| 6.00 | All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before. | 27,098 | Each | 0.2 ₹5,419.6 | 0.5 ₹13,549 | 0.5 ₹13,549 | 1 ₹27,098 | 0.45 ₹12,194.1 | 0.99 ₹26,827.02 | 0.1 ₹2,709.8 Lowest |
| 7.00Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. | ||||||||||
| 7.01 | 16 Sqmm 4 core | 5,500 | RM | 89 ₹4,89,500 | 72 ₹3,96,000 | 95 ₹5,22,500 | 90 ₹4,95,000 | 50 ₹2,75,000 Lowest | 99 ₹5,44,500 | 70 ₹3,85,000 |
| 7.02 | 25 Sqmm 3.5 core | 1,200 | RM | 101 ₹1,21,200 | 99 ₹1,18,800 | 130 ₹1,56,000 | 110 ₹1,32,000 | 95 ₹1,14,000 Lowest | 149 ₹1,78,800 | 100 ₹1,20,000 |
| 7.03 | 35 Sq mm 3.5 core. | 800 | RM | 131 ₹1,04,800 | 135 ₹1,08,000 | 150 ₹1,20,000 | 130 ₹1,04,000 | 115 ₹92,000 Lowest | 199 ₹1,59,200 | 127 ₹1,01,600 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
7 Oct 2020, 6:00 pmClosed
MR ARJUN PATRO
GE U ELECTRIC SUPPLY DELHI CANTT-10
Repair and maintenance of of LT cable LT poles and connected items at Carriapa Vihar 105 TA 1 WEC EETSU DAS Polo Ground Todapur Kandhar Line EME Workshop Lorry Road P H RR Colony 19 P F BD Coy in the area of AGE U Elect Supply No II under GE U Elect
2020_MES_365074_2
GE ELECT/D-70/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹1 L
Yes
19 Oct 2020
30 Sept 2020
9 Oct 2020
1 Oct 2020
7 Oct 2020
2 Oct 2020
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
400 Sqmm single core
630 sqmm single core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends all specified and directed
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :-
25-50 Sqmm x 3.5 core/ 4 core
70-150 Sqmm x 3.5 core
185 -240 Sqmm x 3.5 core
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by E-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.1 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 5 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply & Fix in replacement Transparent KIOSK box weather proof incluiding made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120 mm out side and 300x200x105 mm inside dimensions comprising of aluminium bus bar 4 strip for 3 phase and neutral 63 Amps and incluiding embossing/ painting of danger notice of size not less than 10cm x 7.5 cm with letters,figures band conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer.
M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters as directed.
All as per item No 16 above but of approx size upto 1.90 Sqm
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 5 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.6 mpa working pressure
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swan neck pole type 410 SP-31 (9 mtr long) complete with mild steel base plate, finial taper plug, bolts, nuts and screws including two coats of aluminium painting over a coat of primer for exposed surfaces and two coats of bituminous black paint over a coat of primer to the surfaces in contact with concrete inclusing two runs of PVC insulated 1100V multi-stranded copper wire of size 2.5 Sqmm from the junction box to the fitting complete all as specified and directed. Note :- The unit rate in this item is deemed to be included the cost oif exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside
Trimming and cutting of tree branches coming across LT over head line clearing the line around 1.5m single/both sides and stacking of serviceable material and disposal of unserviceable material to a distance n.exc 50m and cleaning site complete all as directed. Note :(i) Length of span is 35 to 40 RM. (ii) Due care is to be given while trimming/cutting the tree branches that there should no damage to over head line conductor/pole. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra shall be admissible on this account.
S&F in replacement of LT, 1100 volt grade separators suitable for two no O/H conductor on exiting LT o/H Line complete all as directed.
S&F in replacement of LT, 1100 volt grade separators suitable for four no O/H conductor on exiting LT O/H Line complete all as directed.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing octagonal street light poles of 8 mtr height with 150mm bottom dia and 75mm top dia made up of 3mm thick alongwith galvanised base plate of size 225mmx225mmx16mm suitable to with stand maximum wind speed of 169 Km/hr and for mounting , decorative double/single over hand bracket for street light fittings . The internal & external surface of pole shall be dip galvanised 65 microns (minimum) DFT complete all as specified and directed. NOTE:- The unit rate in this item is deemed to be included the cost dismantling of old one pole , exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings .
S&F of stranded aluminium conductor cable PVC sheathed unarmoured , 1100 Volts , flat twin core of following sizes:-
Supply and fixing in replacement of LED street light fittings capacity 60 Watt Endura Cityliner Neo LED street light complete all as specified and directed . Make Havells
M & L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel/LT ACB panel and removing all rubbish to a distance not exceeding 50 m as directed.
Supply and fixing in renewal of Analog Time switch Cat No J648B1, 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable time switch complete all as specified and directed.
Supplying and fixing in replacement LED flood light fitting of following size complete all as specified and directed by Engr-in-charge :-
Supply installation & commissioning in replacement of 12 Volts-100 AH sealed maintenance free battery suitable for solar street light complete all as specified and directed by Engr-in-charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
Rajindera Enterprises
mayur enterprises
DS CONSTRUCTION
M/s Adhikari construction co.
MV Engineers And Contractors
Vijay Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .