Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.1 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | 1 | Accepted-AOC ACCEPTED BEING THE LOWEST TENDERER | |
| 2 | 2₹21.6 L+₹53,776.90 (2.55%)Rejected-Finance A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹25.0 L+₹3.9 L (18.7%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹25.1 L+₹4.0 L (19.2%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹25.3 L+₹4.2 L (20.0%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Nov 2023, 6:00 pmClosed
CWE(AF) JORHAT
CWE (AF) Jorhat ROWRIAH 785004
84008/E8 REPAIR MAINT OF HT 11 KV 33 KV NETWORK ALONGWITH CABLE VCBS SF6 RING MAIN POWER AND DISTRIBUTION TRANSFORMERS AND OTHER CONNECTED ITEMS AT AF STN MOHANABRI UNDER GE AF MOHANBARI
2023_MES_620337_1
84008/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MOHANBARI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(AF) MOHANBARI
₹50,000
Yes
17 Nov 2023
23 Sept 2023
3 Nov 2023
24 Sept 2023
1 Nov 2023
20 Oct 2023
Amount
Demolition/ Dismantling Cement Concrete of any description and in any Position including Removing Debris, etc. Outside of AF Land, complete all as specified and as directed.
Demolition Brick Masonry of any description, built in Cement Mortar including all quoins, arches, pillars, etc, including Removing Debris, etc. Outside of AF Land, complete all as specified and as directed.
Dismantling Cross-arms, Channel or Angle Sections, Mild Steel Works of any description, Segregation of Serviceable Materials Keep in Safe Custody for Re-use (if any), complete all as specified and as directed.
Dismantling Plain or Corrugated Steel Sheeting, any gauge, thickness, including Nainital or Similar Pattern Roof Coverings, complete all as specified and as directed.
Taking out Serviceable/ Unserviceable HT UG Cable of Cross Sectional Area 95 Sqmm, 3 Core from Trench/ Duct/ Pole after disconnecting Electrical Connection including Recovering Cable Protection Covers, Pipes, etc. of any descriptions, Segregation of Serviceable Cable Protection Cover, Pipe, etc. and Keep in Safe Custody for Reuse including Tracing the location of Fault, complete all as specified and as directed. NOTE : Necessary Earth Work will be Measured and Paid for separately under appropriate Items.
Excavation in Trenches not exc. 1.50 Metre Wide and not exc. 1.50 Metre Depth for Taking Out/ Laying of Under Ground Cable, Pole, Pipe, Stay and Getting Out in Soft Soil Strata including Making Good to the Disturbed Surfaces such as Hardstanding/ Footpath/ Pavements, complete all as specified and as directed.
Excavation Over Areas not exc. 1.50 Metre Depth in Soft/ Loose Soil mixed with Sand, Broken Bricks, Aggregate, etc. and Getting Out, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in Layers not exc. 25 Cm, Spread any type of Soil, complete all as specified and as directed.
Removing Excavated Materials not exc. 50 Metre and depositing where directed at a Level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
Removing Excavated Materials exc. 250 Metre but not exc. 500 Metre Outside of AF Land and Depositing where directed in a Level not exc. 1.50 Metre above the Starting Point of any type of Mixed Soil with Sand, Broken Bricks, Aggregate, etc., complete all as specified and as directed.
M&L Boring of Holes Under Road, Pavement, Hardstanding by Trenchless Technology Using Ultra Sounding Technique and necessary Machine, complete all as specified and as directed.
M&L Loose Filling with Broken Stone Aggregate 40mm to 80mm graded, Spreading to a True Surface and Leveled in Layers not exc. 20 Cm thick for Switch Yard, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded aggregate) in Foundation Platform including necessary Formwork, complete all as specified and as directed. NOTE : Cost of Formwork will deemed to be included in the Quoted Unit Rate.
M&L Brick work with Sub-class ‘B’ Bricks, Straight or Curved on Plan exc. 6.0 Metre Mean Radius, Built in Cement Mortar 1:4, complete all as specified and as directed.
M&L Pre-painted Galvalume Aluminium Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick of Red Colour having Tensile Strength of 550 Mpa as in Roof Covering / Cladding to Wall, Fixed with Self Tapping Screws, complete all as specified and as directed.
M&L Mild Steel Cross-arms, Bracing, Supports, Clamps and Back Plates, fabricated from Structural Steel Section including Nut, Bolts, Washers, Welded, Binding, Cold or Hot, Drilling Holes for Bolts in any Shape or Size as required duly Painted with Two Coats of Aluminium Paint over a coat of Red Oxide Zinc Chrome Primer after Preparation of Surfaces, complete all as specified and as directed.
M&L Mild Steel Chequered Plate Fe-410-W (gde-E-250), 7.0mm thick Square Cut or Notched, Forming Holes without any Attachment as Duct Covering Size and Length as Approved including Primer Painting, complete all as specified and as directed.
M&L Anti Climbing Device, Spikes type, Fabricated out of Mild Steel Bars (Round, Square and Flat) including Nuts, Bolts, Washers and Welding in Two Halves, made to Shape to Suit the Cross Section of the Poles or as ordered, complete all as specified and as directed.
M&L Anti Climbing Devices Comprising 2.24mm dia Galvanised Steel 2-strand Barbed Wire with 2.0mm dia Barbs wrapped Spirally Round Poles, to a Length of 0.5 to 1.0 Metre, Clamped and Properly Secured or as ordered, complete all as specified and as directed. NOTE : Clamps required will be Measured and Paid for separately under appropriate Items.
S&F Gang Operated Air break Switch Triple Pole, Mechanically Manual operated, mounted on 9 No. Insulator and Steel Frame with Operating Mechanism worked from Ground Level, for Current rating upto 400 Amp, 11000 Volt including Taking down Air Break Switch of any description, complete all as specified and as directed.
S&F Gang Operated Air break Switch Triple Pole, Mechanically Manual operated, Rotating type, Outdoor type, mounted on 9 No. Insulator and Steel Frame with Operating Mechanism worked from Ground Level, for Current rating upto 800 Amp, 33000 Volt including Taking down Air Break Switch of any description, complete all as specified and as directed.
S&F Lightning Arrester Expulsion type Complete with all Fittings, Transmission Class, Discharge Capacity 65 Kilo Amp, 11000 Volt including Taking down Lightning Arrester of any description, complete all as specified and as directed.
S&F Lightning Arrester Expulsion type Complete with all Fittings, Transmission Class, Discharge Capacity 65 Kilo Amp, 33000 Volt including Taking down Lightning Arrester of any description, complete all as specified and as directed.
S&F Danger Notice Plate of Size 25x20 Cm for HT 11KV, made out of 1.6mm thick Mild Steel Sheet, Vitreous Enameled White with Letters, Figures and Conventional Skull & Bones in Signal Red Colour and fixed with and including suitable Size Mild Steel Clamps, Bolts, Nuts including Taking down Danger Notice Plate of any description, complete all as specified and as directed.
S&F Synthetic Rubber Insulated Mat 2.5mm thick for 11 KV for Electrical purpose as per IS:15652-2006 (superseding IS 5424) suitable for Electrical Shock Safety of Size 2.0 x 1.0 Metre including Removing Insulated Mat of any description, complete all as specified and as directed.
Supplying, Fixing/ Laying, Testing & Commissioning XLPE insulated, screened, PVC Bedded, Galvanised Steel Strip or Wire Armoured, Electric Power Cable (Heavy duty) with Aluminium Conductor, 11000 Volt (Earthed type) Grade of Cross Sectional Area 95 Sqmm, 3 Core, Laid in Trenches/ on Wall/ Pole/ Duct/ Pipe including suitable Size of Mild Steel Saddle Clips (wherever Cable Laid in Ceilings/ Walls without Cable Duct) and Connecting, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured and Paid for separately under appropriate Items.
Re-laying/ Re-routing of Serviceable HT Cable of Size 95 Sqmm, 3 Core (Serviceable HT Cable obtained from Item No. 5 here-in-before) of any description and Connecting, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured and Paid for separately under appropriate Items.
M&L Cable Jointing Kit for 11 KV (Earthed) grade Cable, Indoor End Termination, Heat Shrinkable type complete with Jointing Materials and Accessories suitable for 95 Sqmm, 3 Core XLPE Armoured Aluminium Conductor Cable, Providing Connection and Testing including Cutting/Taking down Old Cable Joint, complete all as specified and as directed.
M&L Cable Jointing Kit for 11 KV (Earthed) grade Cable, Outdoor End Termination, Heat Shrinkable type complete with Jointing Materials and Accessories suitable for 95 Sqmm, 3 Core XLPE Armoured Aluminium Conductor Cable, Providing Connection and Testing including Cutting/Taking down Old Cable Joint, complete all as specified and as directed.
M&L Cable Jointing Kit for 11 KV (Earthed) grade Cable, Straight Through, Heat Shrinkable type complete with Jointing Materials and Accessories suitable for 95 Sqmm, 3 Core XLPE Armoured Aluminium Conductor Cable, Providing Connection and Testing including Cutting/Taking down Old Cable Joint, complete all as specified and as directed.
M&L Sand Cushioning to Under Ground Cable provided with a layer of Sand 8 Cm Depth before Laying of Cable and 15 Cm Depth and Punned to 15 Cm thick after Laying and Stretching the Cable or Spreading on Surface of Switch Yard, complete all as specified and as directed. NOTE :- (a) Only Punned thickness of Sand Cushioning will be Measured & Paid. (b) Fine Sand, Free from any type of Seeds, Vegetation, Grass, etc. will be laid in Switch Yard and Making Sand Neat and Clean is deemed to be included in Quoted Unit Rate.
Supply and Laying Un-reinforced Pre-Cast Concrete Cable Cover, Class HVP, Type 2 with Peak, Size 450x180x40mm, complete all as specified and as directed.
Relaying Old Serviceable Un-reinforced Pre-Cast Concrete Cable Cover (Serviceable Cable Cover obtained from Item No. 5 here-in-before) laid in Trenches for Mechanical Protection of UG HT Cable, complete all as specified and as directed.
Supplying & Laying/ inserting to Boring of Hole HDPE Pipe of 150mm dia suitable for 0.4 mpa Working Pressure, complete all as specified and as directed.
M&L Servicing-cum-Repairs to RMU SF6 Panel of Capacity 630 Amp, 11 KV, 3 Pole, Outdoor type, MAKE : ABB by Opening all Covers/ Strips, Cleaning, Servicing/ Overhauling, Lubricating, Internally & Externally, All Contacts, Springs, Tripping System including Adjustment, Tightening, Filling of Gas and Setting of All Contacts and Inserting it in its Original Position, Re-assembling all Parts and Fixing in its Panel for Smooth Functioning of the Circuit Breaker to the Entire Satisfaction Taking down/out Old Unserviceable Parts, complete all as specified and as directed. NOTE : Unserviceable Parts required to make the RMU SF6 Panel Serviceable will be Measured & Paid separately as 'Supply only'.
Supply only HT Bushing (as per Sample Approved) suitable for RMU SF6 Panel of Capacity 630 Amp, 11 KV, MAKE : ABB, complete all as specified and as directed.
Supply only Bushing O-Ring (as per Sample Approved) suitable for RMU SF6 Panel of Capacity 630 Amp, 11 KV, MAKE : ABB, complete all as specified and as directed.
Supply only HV Back-up Fuse Link 13-72A, 11 KV, Breaking capacity 63 kA (MAKE : ABB, Product ID No. 1YMB531004M0004) suitable for RMU SF6 Panel of Capacity 630 Amp, 11 KV, MAKE : ABB, complete all as specified and as directed.
Supply only SF6 Gas (as per Sample Approved) suitable for RMU SF6 Panel of Capacity 630 Amp, 11 KV, MAKE : ABB, complete all as specified and as directed.
Supply only Empty Cylinder 9.0 KG (as per Sample Approved) suitable for RMU SF6 Panel of Capacity 630 Amp, 11 KV, MAKE : ABB, complete all as specified and as directed.
Supply only Gas Charging Kit (as per Sample Approved) suitable for RMU SF6 Panel of Capacity 630 Amp, 11 KV, MAKE : ABB, complete all as specified and as directed.
M&L Servicing, Calibration & Testing 11 KV HT Relays Provided with 3 Pole, 630 Amp VCB HT Panel of Make : KIRLOSKAR such as Instantaneous Earth Fault, Auxiliary Relay, Earth Fault, Under Voltage, Over Current Relay and Adjustment the Time for Proper Tripping with respect to Main Incoming/ Load including Primary & Secondary Testing of Relay by Current Injection with Testing Equipments, complete all as specified and as directed. NOTE : AC/ DC Current/ Voltage Injection Testing Kit for Primary & Secondary Testing of Relay will be arranged by the Contractor and necessary Charges for the same shall deemed to be included in the Quoted Unit Rate.
M&L Servicing, Calibration & Testing 33 KV HT Relays provided with 3 Pole, 800/1250 Amp VCB HT Indoor/ Outdoor Panel of MAKE : ABB/ KIRLOSKAR such as instantaneous Earth Fault, Auxiliary Relay, Earth Fault, Under Voltage, Over Current Relay and Adjustment the Time for proper Tripping with respect to Main Incoming/ Load including Primary & Secondary Testing of Relay by Current Injection with Testing Equipments, complete all as specified and as directed. NOTE : AC/ DC Current/ Voltage Injection Testing Kit for Primary & Secondary Testing of Relay will be arranged by the Contractor and necessary Charges for the same shall deemed to be included in the Quoted Unit Rate.
S&F Over Current & Earth Fault Relay, Fully Digital type, based on Microprocessor Technology with LCD Display, duly Programmed as required on Site suitable for Protection/ Tripping of HT 11 KV, 630 Amp, 3 Pole VCB Panel of MAKE : KIRLOSKAR including carry out necessary Modification in existing Panel including Taking down/out Old Unserviceable Relay of any description, complete all as specified and as directed. MAKE : ABB/ CG/ KIRLOSKAR
Taking out Serviceable/ Unserviceable VCB of Capacity 630 Amp, 11 KV, 3 Pole of MAKE : KIRLOSKAR from HT Panel for Repairing/ Servicing, Opening all Covers/ Strips, Cleaning, Servicing/ Overhauling, Lubricating, Internally & Externally, all Contacts, Springs, Tripping System including Adjustment, Tightening including Replacement of necessary Connector, Gasket and Setting of All Contacts and Inserting it in its Original Position, Re-assembling all Parts and Fixing in its Panel for Smooth Functioning of the Circuit Breaker to the Entire Satisfaction, complete all as specified and as directed. NOTE : Unserviceable Parts required to make the VCB Serviceable will be Measured & Paid separately as 'Supply only'.
Supply only Earth Contact Assembly (as per Sample Approved) suitable for 630 Amp, 11 KV, suitable for VCB of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fixed Contact Assembly (as per Sample Approved) suitable for 630 Amp, 11 KV, suitable for VCB of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Isolate Contact Assembly (as per Sample Approved) suitable for 630 Amp, 11 KV, suitable for VCB of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Moving Contact Assembly (as per Sample Approved) suitable for 630 Amp, 11 KV, suitable for VCB of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Tripping Coil Assembly (as per Sample Approved) suitable for 630 Amp, 11 KV, suitable for VCB of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Spring Charging Motor 230 Volt AC complete with Gear Box Mechanism (as per Sample Approved) suitable for 630 Amp, 11 KV, suitable for VCB of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Digital Ammeter 3 Phase, Accuracy Class 1 (as per Sample Approved) suitable for HT 11 KV, 630 Amp, 3 Pole VCB Panel including carry out necessary Modification in existing Panel, complete all as specified and as directed.
Supply only Digital Voltmeter 3 Phase, Accuracy Class 1 (as per Sample Approved) suitable for HT 11 KV, 630 Amp, 3 Pole VCB Panel including carry out necessary Modification in existing Panel, complete all as specified and as directed.
Supply only LED Indicator (Colour as per Site requirement and as per Sample Approved) suitable for HT 11 KV, 630 Amp, 3 Pole VCB Panel including carry out necessary Modification in existing Panel, complete all as specified and as directed.
Supply only Push Buttom (Colour as per Site requirement and as per Sample Approved) suitable for HT 11 KV, 630 Amp, 3 Pole VCB Panel including carry out necessary Modification in existing Panel, complete all as specified and as directed.
Supply only ON/ OFF Indicator (as per Sample Approved) suitable for HT 11 KV, 630 Amp, 3 Pole VCB Panel including carry out necessary Modification in existing Panel, complete all as specified and as directed.
Supply only Motor Charging Mechanism Assembly (as per Sample Approved) suitable for HT 11 KV, 630 Amp, 3 Pole VCB Panel including carry out necessary Modification in existing Panel, complete all as specified and as directed.
Disconnecting Distribution Transformer Outdoor/ Indoor type from HT and LT Side, Opening Carefully at Site, Draining out Transformer Oil and Keep Safe in Barrel for Reuse upto HT/ LT Box for Rectifying the Leakage by Replacing the Unserviceable Spare Parts of Capacity 100 KVA to 400 KVA, 11/ 0.433 KV Transformer, Refilling the Transformer Oil and Re-assembling after Repaired including Testing for any Oil Leakages and Connecting the HT/ LT Side and Testing on Available Electric Load, complete all specified and as directed. NOTE :- (a) Defective Parts shall be Measured & Paid separately as 'Supply only'. (b) Charges of Welding work (if required) will deemed to be included in the Quoted Unit Rate.
Supply only LT Bushing with Brass Stud (as per Sample Approved) suitable for 100 KVA to 400 KVA, 11/ 0.433 KV Transformer, complete all as specified and as directed.
Supply only HT Bushing with Brass Stud (as per Sample Approved) suitable for 100 KVA to 400 KVA, 11/ 0.433 KV Transformer, complete all as specified and as directed.
Supply only Top Cover Gasket Set (as per Sample Approved) suitable for 100 KVA to 400 KVA, 11/ 0.433 KV Transformer, complete all as specified and as directed.
Supply only Oil Level Indicator alongwith Connected Accessories (as per Sample Approved) suitable for 100 KVA to 400 KVA, 11/ 0.433 KV Transformer, complete all as specified and as directed.
S&F Air Breather Assembly Transparent Plastic body with Top and Bottom Portion Pressed with Metallic Cover, Filled with New Silica Gel (Blue in Colour) suitable for 100 KVA to 400 KVA, 11/ 0.433 KV Transformer, fixing on existing Pipe of Size 15/20/25mm dia with suitable Reducer/ Connector complete as per Site requirement including Taking down/out Old Unserviceable Air Breather Assembly, complete all specified and as directed. NOTE : Cost of Modification (if required to fix on existing Mild Steel Pipe) will deemed to included in the Quoted Unit Rate.
S&F Air Breather Assembly Transparent Plastic body with Top and Bottom Portion Pressed with Metallic Cover, filled with new Silica Gel (Blue in Colour) suitable for 1.25/2.5 MVA, 33/11 KV Transformer, fixing on existing Pipe of Size 15/20/25 mm dia with suitable Reducer/ Connector complete as per Site requirement including Taking down/ out Old Unserviceable Air Breather Assembly, complete all specified and as directed. NOTE : Cost of Modification (if required to fix on existing Mild Steel Pipe) will deemed to included in the Quoted Unit Rate.
M&L Lifting Distribution Transformer of Capacity upto 250 KVA, 11/ 0.433 KV carefully by suitable Arrangements (Crane) after Disconnecting all HT/ LT Electrical Connections, Earthing Strips, Foundation Nuts & Bolts and Shifting to a Location not more than 100 Metre and Re-connecting all Electrical Connection to its Original Position, complete all as specified and as directed. NOTE : Earth Works required for Re-routing of Cable Lines will be Measured & Paid separately.
Supply & Toping up of New Transformer Oil (in Sealed Barrel) confirming to IS:335 Std having Dielectric Strength 40 KV at 2.5mm Gap after Initial Dehydration, complete all as specified and as directed. MAKE : CASTROL/ POWER TRUE/ SAVITA/ TRUOIL
M&L Dehydration & Filtration of Transformer Oil by Dehydration Plant (Plant brought at Site) including Testing of Sample 'Before' and 'After' Dehydration & Filtration to achieved 40 KV at 2.5mm Gap, complete all as specified and as directed. NOTE :- (a) Filtration of the Transformer Oil will be carried out at Different Sub-stations of AF STN MOHANBARI. (b) Report Before Filtration & After Filtration to be submitted by Contractor. (c) Transformer Oil for Topping up will be Measured & Paid separately.
M&L Spray Painting (including suitable Capacity Air Compressor brought at Site) to Old Painted Steel or Iron Surface of Transformer of Capacity upto 250 KVA (11/0.433KV) complete with all Connected Fittings and Fixtures i.e. Buchholz Relay, Conservator Tank, Cooling Fins and Other Standard Fittings and Attachments as per existing Colour Scheme and Pattern with at least Two Coats of Synthetic Enamel Paint (of Approved Tint) after necessary preparation of Surfaces including Cleaning with Scrapers and Emery Papers to entire Satisfaction of Engineer-in-Charge, complete all as specified and as directed. NOTE : Contractor will apply one layer of Grease over Specifications Plate/ any written Letters before Painting and Cleaning the same after Painting for which Cost of the same will deemed to be included in the Quoted Unit Rate.
M&L Spray Painting (including suitable Capacity Air Compressor brought at Site) to Old Painted Steel or Iron Surface of Transformer of Capacity upto 400 KVA (11/0.433KV) complete with all connected Fittings and Fixtures i.e. Buchholz Relay, Conservator Tank, Cooling Fins and Other Standard Fittings and Attachments as per existing Colour Scheme and Pattern with at least Two Coats of Synthetic Enamel Paint (of Approved Tint) after necessary preparation of Surfaces including Cleaning with Scrapers and Emery Papers to entire Satisfaction of Engineer-in-Charge, complete all as specified and as directed. NOTE : Contractor will apply one layer of Grease over Specifications Plate/ any written Letters before Painting and Cleaning the same after Painting for which Cost of the same will deemed to be included in the Quoted Unit Rate.
M&L Spray Painting (including suitable Capacity Air Compressor brought at Site) to Old Painted Steel or Iron Surface of Transformer of Capacity 1.25/ 2.5 MVA (33/11KV) complete with all connected Fittings and Fixtures i.e. Buchholz Relay, Conservator Tank, Cooling Fins and Other Standard Fittings and Attachments as per existing Colour Scheme and Pattern with at least Two Coats of Synthetic Enamel Paint (of Approved Tint) after necessary preparation of Surfaces including Cleaning with Scrapers and Emery Papers to entire Satisfaction of Engineer-in-Charge, complete all as specified and as directed. NOTE : Contractor will apply one layer of Grease over Specifications plate/any written Letters before Painting and Cleaning the same after Painting for which Cost of the same will deemed to be included in the Quoted Unit Rate.
M&L Painting 33 KV GOD Frame Structure consisting 4 No. Vertical Mild Steel Angle of Length not more than 4.0 Metre (except Embedded Portion) complete including all Mild Steel Vertical/ Horizontal/ Diagonal Angle work, mounted on Poles with Two Coats of Aluminium Paint after necessary Preparation of Surfaces including Cleaning/ Scrapping carefully Old Corroded Paint Dirt/ Dust/ Rust, etc. including Providing of Red Colour Bands/ Straps not exc. 30 Cm with Synthetic Enamel Paint (of Approved Tint) as per existing Pattern, complete all as specified and as directed.
M&L Preparing Old Painted Steel or Iron Surfaces of any description including Cleaning with Scrapers and Emery Papers, over 10 Cm in Width or Girth, not otherwise described and Applying Two Coats of Synthetic Enamel Paint (of Approved Tint) with Spray Painting Machine, complete all as specified and as directed. NOTE : Contractor will apply one layer of Grease over Specifications Plate/ any written Letters before Painting and Cleaning the same after Painting for which Cost of the same will deemed to be included in the Quoted Unit Rate.
M&L Painting of 33 KV Bus-bar Frame structure consisting 9 No. Steel Tubular Swaged Poles of 11.00 Metre long (except Embedded Portion) complete including all Mild Steel Vertical/ Horizontal/ Diagonal Angle work, mounted on Poles with Two Coats of Aluminium Paint after necessary Preparation of Surfaces including Cleaning/ Scrapping up of Old Corroded Paint Dirt/ Dust/ Rust Carefully complete including Providing of 7 No. Bands/ Straps 30 Cm Wide with Synthetic Enamel Paint (of Approved Tint) from Top of Plinth Block and Writing of Pole Number with White Synthetic Enamel Paint on Black Colour Back Ground, complete all as specified and as directed.
M&L Painting to Erected Steel Tubular Swaged Pole of HT Over head Line of 11.00 Metre long (except Embedded Portion) complete including all Mild Steel Vertical/ Horizontal/ Diagonal Angle work, mounted on Poles with Two Coats of Aluminium Paint after necessary Preparation of Surfaces including Cleaning/ Scrapping up of Old Corroded Paint Dirt/ Dust/ Rust Carefully complete including Providing of 7 No. Bands/ Straps 30 Cm Wide with Synthetic Enamel Paint (of Approved Tint) from Top of Plinth Block and Writing of Pole Number with White Synthetic Enamel Paint on Black Colour on Back Ground, complete all as specified and as directed.
M&L Writing Letters or Figures (Block, Roman, Italic or Indian) not exc. 30 Cm High with Synthetic Enamel Paint (of Approved Tint) as Per Colour Scheme, complete all as specified and as directed.
S&F Flex Fiber Board of minimum thickness 5.0mm, Surface/ Wall mounting type, Digitally Printed with Letters or Figures (Block, Roman, Italic or Indian) as per Sample including Cutting into Pieces as per Site requirement including Taking down/ out Old Unserviceable Board, complete all as specified and as directed.
LESS SCHEDULE OF CREDIT NOTE : Bidders are required to Quote the SAME AMOUNT (as per SCHEDULE OF CREDIT including NOTES therein of Tender documents) under Column 'UNIT RATE' (M) against Row No. 90.
kabitaconstruction
STANDARD ELECTRIC WINDERS
Singhs Construction
M/s HALDER ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .