Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹10.4 L+₹27,270 (2.69%)Rejected-Finance 1087 LASKARHAT KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L2 | Rejected-Finance Quoted higher than L1. | |
| 3 | L3₹10.5 L+₹40,770 (4.03%)Rejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Quoted higher than L1. |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
16 Jul 2024, 6:00 pmClosed
University Engineer, C.U.
Office of the University Engineer Darbhanga Building, 87/1 College Street Kolkata- 700073, University of Calcutta.
HIRING ON RENTAL BASIS FOR URGENT SUPPLYING, INSTALLATION,TESTING AND COMMISING OF OIL TYPE 750KVA OIL-NATURAL AND AIR-NATURAL-ONAN- DYN11 TRANSFORMER IN PALCE OF BURNT, DEFECTIVE EXISTING OIL TYPE 750 KVA ONAN TRANSFORMER IN BALLYGUNGE SC COLLEGE,CU
2024_CU_704886_1
E-tender/Eng/EQ-75/24-25
Open Tender
MISC ELECTRICAL WORKS
Item Rate
270 days
BALLYGUNGE SCIENCE COLLEGE CAMPUS, C.U.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹20,000
13 Nov 2024
2 Jul 2024
18 Jul 2024
2 Jul 2024
16 Jul 2024
2 Jul 2024
Amount
HIRING ON RENTAL BASIS FOR URGENT SUPPLYING, INSTALLATION, TESTING AND COMMISING OF OIL TYPE 750KVA OIL-NATURAL AND AIR-NATURAL (ONAN) DYN11 TRANSFORMER IN PALCE OF BURNT AND DEFECTIVE EXISTING OIL TYPE 750 KVA ONAN TRANSFORMER IN BALLYGUNGE SCIENCE COLLEGE CAMPUS UNDER THE UNIVERSITY OF CALCUTTA as mentioned below: Capacity Cast Resin Dry Type Transformer having6/0.433 KV, 3Phase,50Hz,Dyn11vectorgroup, copperwound,classF insulation associated with winding temperature indicator/controller actuated by means of resistance temperature detector embedded in LV windings, IndoorTransformer with approximately 5 % impedance, tapping for ON Load operation on HVsideinstepsof+/-2.5%,+/-5%&-7.5% voltage range, having cable in boxes on HVside suitable for3X240sq.mmXLPE cable of 11 KV (E) grade & bustrunking arrangement on LV side with neutral brought out seperately i/c supplying &Layingof armoured copper conductor multicore control cable from transformer to HT Breaker for safety tripping ,suitably mountedon MSchanneli/csupplyingandgroutingofMSchannelwithall accessories and conforming to IS 11171-1985& as per specification attachedcompleteinall respects as required at site. .Dismantling of LT 3.5 X 300 Sq. mm Al. cable fromtransformer, dismantling of HT PILC cable after de-compound from transformer, & REconnection of this cables in new rental transformer, removing of existing old out dated 750 KVA ONAN oil type transformer from transformer room and keep the all materials within 100Mtrs. away from is initials position etc. as required incl to & fro carriage(from owners godown to site & vice-versa) loading unloading etc. all complete
S. R. ENTERPRISE
S. A. ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .