| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAdmitted-Finance | ₹26.3 L | L1 | Admitted-Finance |
| 2 | L2₹28.8 LAdmitted-Finance | ₹28.8 L | L2 | Admitted-Finance |
| 3 | L3₹45.0 LAdmitted-Finance | ₹45.0 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical FIRST FLOOR 1115 SECTOR 17B 1115 FIRST FLOOR SECTOR 17B GURUGRAM GURGAON HARYANA HARYANA GURGAON HARYANA 122002 UDYAM HR 05 0001805 | GURUGRAM | HARYANA | 122002 | - | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | AIRTEK HVAC LLP L1 | M/s Associated Engineers L3 | Air-O-Mec Engineers L2 |
|---|---|---|---|---|---|---|
| 1.00PART A Supply and Installation | ||||||
| 2.00 | Design, manufacturing and supply of Carrier/Daikin/Media make 11TR Nominal Capacity ductable type split AC systems, air cooled on the secondary side, as per
Basis of Design & Scope of Work & Specification
consisting of two outdoor units having Single Scroll compressor of Danfos/Emerson make with one ceiling suspended type ducted indoor unit, multi speed blower with plenum, Dx cooling coil with hydrophilic coating, Filters with frame work, drive motors, all electrical safety & protection, Internal power and control cabling, Corded/cordless remote control, factory filled refrigerant,etc.. The AC system shall be equipped with all accessories, hardware, and other supporting systems etc. required to deliver designed conditions to the entire satisfaction of TIFR. The system shall run with R410a Refrigerant and be with air cooled condensers comprising copper tubes and AL fins with anti-corrosive coating, its fan with motors, HP & LP switch, factory built solenoid isolation valves for pump down, controls starter, microprocessor control panel, internal control & power wiring and other accessories, hardware enclosed in IP-55 cabinet assembly with weather resistant painting/powder coating for highly corrosive and aggressive coastal ambient conditions for continuous operations | 2 | Nos | 5,00,000 ₹5.9 L | 6,90,000 ₹8.1 L | 5,27,300 ₹6.2 L |
| 3.00 | Installation, Testing & Commissioning of ductable Air-conditioning system comprising one ceiling suspended Indoor Unit, pair of Outdoor Unit , refrigerant piping between outdoor unit and indoor units, electrical cabling between indoor units & outdoor unit, power/control cabling, all system control safety, First charge of Refrigerant. S&I of canvass connection for indoor units,etc. Each Unit should have a factory fitted isolation valves for refrigerant pump down, top up of additional refrigerant, if required. | 2 | Job | 24,000 ₹28,320 | 1,10,000 ₹1.3 L | 26,800 ₹31,624 |
| 4.00 | Supply, Installation, testing & commissioning of suitable size of Seamless, Hard Drawn Refrigerant Copper Piping connecting outdoor to Indoor AC Units .The Refrigerant pipe work shall be suitable for Refrigerant with 13mm thick Nitrile rubber insulation on liquid line and 19mm thick Nitrile rubber insulation on suction line. The thickness of the refrigerant pipe is as per ASTM B88 L-Type standard. The cost should be inclusive of Supply & Installation of necessary supports, fittings, valves, etc. Exposed insulated refrigerant piping should be protected rom degrading as specified in the tender. | 100 | Mtr | 1,52,000 ₹1.8 L | 3,00,000 ₹3.5 L | 1,82,000 ₹2.1 L |
| 5.00Design, fabrication, supply, installation, testing and commissioning of GSS ducting of following size with all the accessories like turning vanes, elbows, flange, epoxy painted supports, gaskets, nuts, and bolts, all the hardware etc. including volume control dampers opposed blade type, complete in all respects to the entire satisfaction of the department as per technical specifications in totality including making duct layout drawing | ||||||
| 5.10 | 24 SWG | 3,700 | Sqft | 4,81,000 ₹5.7 L | 5,55,000 ₹6.5 L | 4,14,400 ₹4.9 L |
| 5.20 | 22 SWG | 800 | Sqft | 1,12,000 ₹1.3 L | 1,44,000 ₹1.7 L | 1,00,000 ₹1.2 L |
| 6.00 | Supply & installation of thermal insulation for Supply & Return air ducting with Nitrile based rubber having Class ‘O’ rating of thickness 19 mm including sealant between duct and insulation. The finished insulation surface shall be applied with one coat of Star Bond 3036 (Paramount make) or Pidilite make lag coating AF5990Immediately after the coat, Fiber cloth of 10 Mil (thickness) having the density of 200gsm shall be wrapped on the surface. The finished insulated duct surface with fiber cloth than be applied with 2 coat of Star Bond 3036 (Paramount make) or Pidilite make lag coating AF5990. | 4,500 | Sqft | 5,85,000 ₹6.9 L | 9,00,000 ₹10.6 L | 4,59,000 ₹5.4 L |
| 7.00 | Supply & Installation of Heavy duty stainless Steel Volume Control Damper with all accessories like gasket, nut bolts, etc as per specification. | 8 | Sqft | 8,400 ₹9,912 | 32,000 ₹37,760 | 7,280 ₹8,590.40 |
| 8.00 | Supply, Installation & Testing of suitable size CPVC pipes for drain piping with 9mm thick Nitrile rubber insulation upto the drain point as per specification from each Indoor AC Unit. | 30 | Mtr | 4,050 ₹4,779 | 15,000 ₹17,700 | 7,050 ₹8,319 |
Tender Value
₹21.5 L
EMD Value
₹41,000
Closing Date
27 Dec 2025, 3:00 pmClosed
Director
TIFR Mumbai
Design Supply Installation Testing and Commissioning ductable air conditioning units for Helium compressor room of LTF with associated ducting and insulation refrigerant and drain piping Electrical works etc at TIFR Colaba, Mumbai 05
2025_DAE_889367_1
TIFR/PD/CF25-35/251088
Open Tender
Electrical Works
140 days
TIFR Mumbai
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹41,000
29 Jan 2026
11 Dec 2025
29 Dec 2025
11 Dec 2025
27 Dec 2025
11 Dec 2025
PART A Supply and Installation
Supply, Installation, testing & commissioning of suitable size of Seamless, Hard Drawn Refrigerant Copper Piping connecting outdoor to Indoor AC Units .The Refrigerant pipe work shall be suitable for Refrigerant with 13mm thick Nitrile rubber insulation on liquid line and 19mm thick Nitrile rubber insulation on suction line. The thickness of the refrigerant pipe is as per ASTM B88 L-Type standard. The cost should be inclusive of Supply & Installation of necessary supports, fittings, valves, etc. Exposed insulated refrigerant piping should be protected rom degrading as specified in the tender.
Design, fabrication, supply, installation, testing and commissioning of GSS ducting of following size with all the accessories like turning vanes, elbows, flange, epoxy painted supports, gaskets, nuts, and bolts, all the hardware etc. including volume control dampers opposed blade type, complete in all respects to the entire satisfaction of the department as per technical specifications in totality including making duct layout drawing
Supply & installation of thermal insulation for Supply & Return air ducting with Nitrile based rubber having Class ‘O’ rating of thickness 19 mm including sealant between duct and insulation. The finished insulation surface shall be applied with one coat of Star Bond 3036 (Paramount make) or Pidilite make lag coating AF5990Immediately after the coat, Fiber cloth of 10 Mil (thickness) having the density of 200gsm shall be wrapped on the surface. The finished insulated duct surface with fiber cloth than be applied with 2 coat of Star Bond 3036 (Paramount make) or Pidilite make lag coating AF5990.
S&I of supporting structure like structural steel (MS ‘L’ angle) members duly hot dipped galvanized (minimum 200 micron thickness) with other accessories for supporting the Indoor Units (floor mounted support) & Outdoor Units
Supply & Laying of Suitable size XLPS Copper conductor Armoured electrical power cable suitable for voltage up to 1.1 KV of size complete with end terminations as required between electrical panel and AC Units
PART B Comprehenssive Annual Maintenance Contract
Comprehensive Annual Maintenance contract of Ductable type Air-conditioning system for LTF comprising 2 Nos. 11TR capacity each Programmable Microprocessor based Air cooled ductable AC Units(Indoor & outdoor parts) , connected refrigerant piping, ducting, insulation, electrical panel & cabling, etc. as per tender specification. The Annual maintenance contract shall start after the expiry of Guarantee period. Order for Comprehensive Annual Maintenence Contract will be released after the expiry of Defect Liability Period.