| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹14.1 L+₹1.2 L (9.52%)Rejected-Finance | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹15.3 L+₹2.5 L (19.4%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance Being not a lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Reject due to not enlisted in specific category i.e C (i) |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
16 Mar 2020, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
COMPREHENSIVE MAINTENANCE OF AIR CONDITIONER AND REPAIR OF SUMMER APPLIANCES, DESERT COOLER, DEEP FREEZER, REFRIGERATOR AND ALLIED SERVICES UNDER GE (WEST) PATHANKOT
2020_MES_325965_1
GE/PKT-72/2019-20
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹40,000
Yes
31 Mar 2020
17 Feb 2020
18 Mar 2020
17 Feb 2020
16 Mar 2020
3 Mar 2020
18 Feb 2020 - 29 Feb 2020
Amount
Repair, rewinding and maintenance of voltage stabilizer of any company/ make of capacity 4 KVA after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of all unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface smooth complete all as specified and directed by Engr- in -charge.
Repair, rewinding and maintenance of voltage stabilizer of any company/ make of capacity 5 KVA after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of all unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface smooth complete all as specified and directed by Engr- in -charge.
Taking down defective AC , window type of capacity upto 2 ton of any make after disconnecting electric connections and transporting to workshop from site, dismantling the AC and taking out burnt rotary / reciprocating compressor unit from AC and replacing the same with new compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge
S&F Starting relay for window AC, split AC. fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Thermostate switch for window AC, hot and cold type fixed in repair all as specified and directed by Engr- in -charge.
S&F Swing motor for window type AC of capacity 1.5 ton as per existing make LG/Voltas/whirlpool fixed in repair complete all as specified and directed by Engr- in -charge..
S&F Running capacitor 50 MFD (ISI Marked) 6pole for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed by Engr- in -charge.
S&F Running capacitor 36 MFD (ISI Marked) for window AC 1.5/2 Ton fixed in repair all as specified and directed by Engr- in -charge.
S&F Front grill of window AC, capacity 1.5/2 ton suitable for existing make (LG/ Carrier/ Sidwal/ Whirlpool) of AC fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Condensing fan of window type AC of capacity 1.5 ton as per existing make (LG/Voltas/Carrier) of AC fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Blower fan of window type AC of capacity 1.5 ton as per existing fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Sheet metal enclosure with MCB single pole 20 Amp 'C' curve for AC fixed in repair complete all as specified and directed by Engr- in -charge.
Servicing of window type AC of capacity 1.5 ton of any make at site with complete washing/ removing of dust from blower fan and necessary oiling the blower motor complete all as specified and directed by Engr- in -charge..
S&F Blower Motor (ISI marked) 1/5 HP capacity of window type AC fixed in repair as per existing make complete all as specified and directed by Engr- in -charge. Make:- Air master/AUE/AE
S&F in replacement of unserviciable Recycle valve kit to maintain the desired temperature of cooling system of window type AC /split type AC as per requirement including gas charging, fixed in repair complete all as specified and directed by Engr- in -charge..
S&F in replacement of unserviciable PCB circuit to window type AC as per existing make (LG/Voltas) complete all as specified and directed by Engr- in -charge.
S&F in replacement filter for window type AC of capacity 1.5 ton/ 2 ton as per existing make (LG/Voltas) complete all as specified and directed by Engr- in -charge.
S&F in replacement of unsv condensing coil for window type AC of capcity 1.5 ton including gas charging, complete all as specified and directed by Engr- in -charge. .
Servicing of split type AC of any capacity and any make with washing/ removing of dust from blower fan and necessary oiling to the blower motor complete all as specified and directed by Engr- in -charge..
S&F Copper pipe of dia 1/4 inch fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Copper pipe of dia 3/8 inch fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Copper pipe of dia 1/2 inch fixed in repair complete all as specified and directed by Engr- in -charge.
Taking down defective split type AC of any capacity /make after disconnecting electric connections and transporting to workshop from site ,dismantling the AC and taking out burnt rotary / reciprocating compressor unit from AC and replacing the same with new compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge.
Taking down defective split type AC of any capacity /make after disconnecting electric connections and transporting to workshop from site, dismantling the AC and taking out burnt rotary / reciprocating compressor unit from INVERTER AC and replacing the same with new compressor of existing make with 12 months warranty including gas charging and testing complete all as specified and directed by Engr- in -charge.
Taking down defective indoor Unit for Split AC 1.5 Ton and replacing the same with new for existing make of AC complete all as specified and directed by Engr- in -charge.
S&F in replacement of PCB circuit hot and cold to split type AC for existing makes of AC complete all as specified and directed by Engr- in -charge.
S&F in replacement of PCB circuit for INVERTER AC hot and cold to split type AC for existing makes of AC complete all as specified and directed by Engr- in -charge.
S&F Blower Motor (ISI marked ) of split type AC fixed in repair complete all as specified and directed by Engr- in -charge..
S&F in replacement swing motor for split type AC of capacity 1.5 ton/2 ton suitable for make LG/ Carrier/ Sidwal/ Whirlpool as per existing complete all as specified and directed by Engr- in -charge.
S&F in replacement of UNSV Air filter for split type AC of any capacity complete all as specified and directed by Engr- in -charge.
S&F in replacement of UNSV Remote control with two AAA battery for split type AC of capacity 1.5 ton /2 ton suitable for make of LG/ Carrier/ Sidwal/ Whirlpool as per existing complete all as specified and directed by Engr- in -charge .
S&F Running capacitor 45 MFD (ISI Marked) fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Insulation material for copper pipe outer covering 25mm thick fixed in repair complete all as specified and directed by Engr- in -charge.
S&F in replacement condensing fan for split type AC of capacity 1.5 ton /2 ton complete all as specified and directed by Engr- in -charge.
S&F in replacement Blower fan for split type AC of capacity 1.5 ton /2 ton complete all as specified and directed by Engr- in -charge.
S&F PVC flexible copper conductor sheathed cable of size 2.5 Sqmm 3 core fixed in repair complete all as specified and directed by Engr- in -charge.
Servicing of water /air type cooling tower complete by changing its acrilic fins inside the bottle and pipes, nozzeles etc including cleaning and spray painting with synthetic enamelled paint complete all as specified and directed by Engr- in -charge.
Repair and maintenance of Central AC plant of capacity 2X50 TON ton at Kiran Auditorium including supply and fixing in replacment of following parts including testing complete:- a) Supply and fixing of air filter As per existing size . (6Nos) b) V-belt B-83 =02 No c) Tyer Coupling TC93 (2 (Nos) d) Servicing of electric motors . e) Cleaning the AHU (2Nos) f) Humidity cantrol system repair, leakage of water (Heating element 2KW = 03 Nos.)
M&L for replacement of old unsv compressor oil (servo) forAC plant complete all as specified and directed by Engr- in -charge. Make :- Indian oil/ BPCL/HPCL
M&L for descaling of condensor of 50 TR capacity of AC Plant with dilute chemical solutionand with the help of nylon brush 3-4 times followed by the cleaning and washing with water so that chemical solution is completely clean out from system complete all as specified and directed by Engr- in -charge.
M&L for cleening of chiller unit 50 TR capacity of AC Plant with dilute chemical solution and with the help of nylon brush 3-4 times followed by the cleaning and washing with water so that chemical solution is completely clean out from system complete all as specified and directed by Engr- in -charge.
Repair and maintenance of package type AC plant of capacity 3.75 ton at EME Bn including supply and fixing in replacment of following parts including testing complete:- a) Supply and fixing of air filter As per existing size . b) V-belt A -20 =01 No c) Temperature control =01 No d) Servicing of condenser fan motor . e) Cleaning the condenser f) Cleaning the cooling coil g) Humidity system repair, leakage of water (Heating element 2KW = 03 Nos.) (h) Supply and replacement of 'U' type heating element - 03 Nos. j) Strip type heating element 3 KW =02 Nos k) Gas charging (F-22)
S&F Oil seal assembly for 50 ton compressor of make voltas model T- 5000 complete all as specified and directed by Engr- in -charge.
M&L for rewinding of Condensor/Chiller Pump motor of 7. 5 HP three phase with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire include servicing, change the unserviceble Bush & shaft & testing complete all as specified and directed by Engr- in -charge.
Supply & Charging Refrigerant R -134 complete one time for top up or making full qty as per pressure requirment of plant and testing for any leakage and rectifying the same all as specified and directed by Engr- in -charge. .
Supply & charging Refrigerant R 22 to Aiir conditioner (window type /split type) of any capacity and make all as specified and directed by Engr- in -charge. .
Supply & Charging Refrigerant R - 410 to Air conditioner (window type /split type )of any capacity and make complete all as specified and directed by Engr- in -charge.
S& F in replacement of existing UNSV Power Contactor ML-2 coil voltage 240 Volt all as specified and directed by Engr- in -charge.
S& F in replacement of existing UNSV Contactor ML-1 coil voltage 240 Volt all as specified and directed by Engr- in -charge.
S&F in replacement of UNSV MCCB 160 amps , triple pole 35 KA rupturing capacity fixing in position and making cable conection including testing on loadall as specified and directed by Engr- in -charge.
S&F in replacement of UNSV MCCB 200 amps , triple pole 35 KA rupturing capacity fixing in position and making cable conection including testing on loadall as specified and directed by Engr- in -charge.
Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 0.5 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of all unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface complete all as specified and directed by Engr- in -charge
Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 1 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of all unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface complete all as specified and directed by Engr- in -charge
Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 2 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface complete all as specified and directed by Engr- in -charge.
Repair, rewinding and maintenance of voltage stabilizer of any company/ make, of capacity upto 3 KVA, after disconnecting the voltage stabilizer from machine, strip opening the stabilizer, finding faults including rewinding transformer with super enamelled copper wire of existing gauge including replacement of unserviceable parts like voltmeter, Amp meter, cutout relay, electric circuit, indicator lamp, top plug, flexible wire including necessary painting with two coats of synthetic enamel paint after proper scratching and preparing the surface complete all as specified and directed by Engr- in -charge.
Supply of unserviceable parts mentioned in srl item No. 01, 02, 52, 53, 54 & 55 shall be measured under following items:-
Supply only Voltmeter as per existing make suitable for voltage stabilizer complete all as specified and directed.
Supply only Amp meter as per existing make suitable for voltage stabilizer complete all as specified and directed.
Supply only Cutout relay as per existing make suitable for voltage stabilizer complete all as specified and directed.
Supply only Electric circuit suitable for voltage stabilizer complete all as specified and directed.
Supply only Indicator lamp as per existing make suitable for voltage stabilizer complete all as specified and directed.
Supply only Flexible wire suitable for voltage stabilizer complete all as specified and directed.
S&F in replacement UNSV Submersible water lifting pump for desert cooler, 230 V ,50 Hz as per existing make of cooler including taking down old pump complete all as specified and directed by Engr- in -charge.
S&F in replacement of UNSV Fan motor of desert cooler 1/7 HP with fan blade & legs single phase 230 V, 50 Hz as per existing make complete all as specified and directed by Engr- in -charge.
M&L for rewinding of desert cooler fan motor of 1/7 HP single phase 3 speed with super enamalled copper wire of appropriate gauge with insulating material complete after removing old burnt winding wire include servicing, change the unserviceble Bush & shaft & testing complete all as specified and directed by Engr- in -charge.
S & F Rubber pipe 15mm dia (ISI marked) heavy grade for desert cooler fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Wood wool pad of size 24" x 18" (set of 3) for desert cooler fixed in repair complete all as specified and directed byEngr- in -charge.
S&F Pad retaining jalli 16 SWG of suitable size of desert cooler (set of 3) fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Water distributor for water connection of desert cooler complete all as specified and directed by Engr- in -charge.
S&F selactor switch for desert cooler for three speed motor ISI Marked all as specified and directed by Engr- in -charge.
S&F Plug top three pin 15 Amps complete all as specified and directed by Engr- in -charge.
S&F Plug top three pin 5 Amps complete all as specified and directed by Engr- in -charge.
S&F PVC connection of size 15mm and 450 mm long with PTMT nuts superier quality fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Stop valve of PTMT of size 15mm, any colour screwed down, high pressure, screwed for iron pipe (ISI marked) fixed in repair complete all as specified and directed by Engr- in -charge.
S&F Ball valve of size 15mm high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe fixed in repair complete all as specified and directed by Engr- in -charge.
Removing of desert coolers from site after disconnecting the electric connection and water connection taking out rusted bottom and replacing with new bottom as per existing size with 24 gauge PGI sheet and transporting back from wksp and installing at site including electric and water connections complete all as specified and directed.
S & F Side shutter of Desert cooler as per existing size with 24 gauge PGI sheet of desert coolercomplete all as specified and directed.
Removing of desert cooler coolers from site after disconnecting the electric connection and water connection taking out rusted Side legs and replacing with new legs as per existing size with 24 gauge PGI sheet and transporting back from wksp and installing at site including electric and water connections complete all as specified and directed.
S&F Capacitor 4 MFD (ISI Marked) fixed in repair all as specified and directed by Engr- in -charge.
Supply & charging Refrigerant R 134 a to Refrigerators of any capaciy, & replace old drier and capillary tube as per existing size any length and make all as specified and directed by Engr- in -charge. .
S&F Starting relay No CAJ -2612 for water cooler all as specified and directed by Engr- in -charge.
S&F Starting relay No CAJ -34 for water cooler fixed in repair all as specified and directed Engr- in -charge.
S&F Starting relay No AHR 13 for water cooler fixed in repair all as specified and directed Engr- in -charge.
S&F Starting capacitor of capacity 80 / 100 MFD (ISI Marked) for water cooler fixed in repair all as specified and directed by Engr- in -charge.
S&F Starting capacitor of capacity 100 / 120 MFD (ISI Marked) for water cooler fixed in repair all as specified and directed by Engr- in -charge.
S&F Over load protector of any size for water cooler fixed in repair all as specified and directed by Engr- in -charge.
S&F Thermostat switch of any size for water cooler fixed in repair all as specified and directed by Engr- in -charge.
Taking out defective condensing coil from water cooler and supply and fixing new condensing coil suitable for unit model CAJ-2612 with gas charging of R-134a as per existing makes of cooler complete all as specified and directed by Engr- in -charge
Taking out defective condensing coil from water cooler and supply and fixing new condensing coil suitable for unit model CAJ-34 with gas charging of R-134a as per existing makes of cooler all as specified and directed by Engr- in -charge
Taking out defective condensing coil from water cooler and supply and fixing new condensing coil suitable for unit model AHR-13 with gas charging of F-22 as per existing makes of cooler complete all as specified and directed by Engr- in -charge.
S&F in replacement Condensing fan blade for water cooler of any size (as per sample kept in GE office) complete all as specified and directed by Engr- in -charge.
S&F Self closing bib cock chromium plated for water cooler of any size fixed in repair all as specified and directed by Engr-in-charge. .
S&F Rubber pipe 1.25 inch dia for water waste of water cooler all as specified and directed by Engr- in -charge. .
S&F Rubber gasket cover of size 1cmx1cm for top cover of water cooler all as specified and directed by Engr- in -charge
Removing of water cooler of model No CAJ-2612 from site after disconnecting electric & water connections and transporting to workshop, taking out burnt compressor and replacing with new compressor suitable for refrigerent gas R-134a of the same make/ company of existing water cooler with 12 months warranty including leakage test, gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge.
Removing of water cooler of model No CAJ-34 from site after disconnecting electric & water connections and transporting to workshop, taking out burnt compressor and replacing with new compressor suitable for refrigerent gas R134a of the same make/ company of existing water cooler with 12 months warranty including leakage test, gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr-in-charge..Make - COPELAND/ VOLTAS
Removing of water cooler of model No AHR-13 from site after disconnecting electric & water connections and transporting to workshop , taking out burnt compressor and replacing with new compressor suitable for refrigerent gas R134a of the same make/ company of existing water cooler with 12 months warranty including leakage test, gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed. at site complete all as specified and directed.Engr- in -charge.
S&F Thermostat switch for refrigerator fixed in repair all as specified and directed by Engr-in-charge.
S&F Blower motor of capacity 1/35 HP for water cooler of capacity 40/80, 60/120 Ltrs fixed in repair all as specified and directed by Engr- in -charge. Make: Air master/AUE/AE
S&F Blower motor of capacity 1/10 HP for water cooler of capacity 150 Ltrs fixed in repair all as specified and directed by Engr- in -charge. Make: Air master/AUE/AE
Supply & Charging Refrigerant R-134a / R-22 to Water Cooler of any capaciy, & replace old drier and capillary tybe as per existing size any length and make all as specified and directed by Engr- in -charge. .
Removal of rusted bottom and repair of body of water cooler of any make and capacity with MS sheet 0.71mm thick, pedestal legs and fixing bottom sheet of suitable existing size and pedstal legs,frame of water cooler by angle iron of size 25x25x3mm and welding including applying one coat of anti corrosive paint by spray machine before fixing all as specified and directed by Engr- in -charge. .
Removal of rusted bottom and repair of body of refrigerator of any make and of capacity 165/ 300 ltrs with MS sheet , pedestal legs and fixing bottom sheet of suitable existing size and pedestal legs, frame of refrigerator with angle iron and welding including applying one coat of anti corrosive paint by spray machine before fixing all as specified and directed by Engr- in -charge.
Removing refrigerator of capacity 280/300ltrs from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with new compressor 1/6 HP Suiteble comperessor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge
Removing refrigerator of capacity 165l//190 litrs from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with new compressor1/8 hp R134a compitable comperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge.
Removing refrigerator of capacity 320ltrs doubble door from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with new compressor R134a compitable comperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge.
Removing Deep Freezer of capacity 200/300 ltrs from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with R134 a compitable comperesssor of the same make/ company of refrigerator with 12 months warranty including leakage test, R134a gas charging, testing including transporting back from workshop and installing at site complete all as specified and directed by Engr- in -charge.
Taking out defective condensing coil from deep freezer and supply and fixing new condensing coil with gas charging of R-134 for existing make of deep freezer complete all as specified and directed by Engr- in -charge
S&F Condensor fan motor for deep freezer of any capacity fixed in repair as per exiting size & make all as specified and directed Engr- in -charge .
S&F in replacement Starting relay for refrigarator of any capacity and make complete all as specified and directed Engr- in -charge
S&F Over load protector of refrigarator of any capacity fixed in repair all as specified and directed by Engr- in -charge
S&F Thermostate switch for deep freezers of refrigerator of any capacity fixed in repair all as specified and directed by Engr- in -charge.
S&F Freezer door of refrigerator of any capacity fixed in repair all as specified and directed by Engr- in -charge
Taking out defective cooling coil from refrigerator and supply and fixing new cooling coil as per existing size and make with gas refilling all as specified and directed by Engr- in -charge
Taking out defective condensing coil from refrigerator and supply and fixing new condensing coil as per existing size and make with gas refilling all as specified and directed by Engr- in -charge.
S&F PVC flexible copper conductor sheathed cable of size 1.5 Sqmm 3 core, fixed in repair complete all as specified and directed by Engr- in -charge.
Removing of water coolers ,Desert cooler , Refrigerator from site after disconnecting the electric connection and water connection and painting with one coat of Red oxide primer and two coats of synthetic enamel paint by spray machine as per existing colour code after scratching the old paint complete and installing at site including electric and water connections all as specified and directed byEngr- in -charge.
Supply & fixing fan motor with fan for Double door Refrigerator as per existing make and size complete all as specified and directed.
Supply & fixing vegitable tray for Refrigerator of suitable size complete all as specified and directed.
Supply & fixing bulb for Refrigerator of suitable size complete all as specified and directed.
Supply & fixing Racks Jali for Refrigerator of suitable size complete all as specified and directed.
Supply & fixing sliding glass for Refrigerator of suitable size complete all as specified and directed.
Supply & fixing bottle support for Refrigerator of suitable size complete all as specified and directed.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 79,450.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 5% (Five percent) of the accepted contract sum shall be delivered by the successful bidder within 28 days from the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
M/S NILESH ENTERPRISES
VIRAT CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .