Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹22.6 L+₹90,788.71 (4.18%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹22.8 L+₹1.1 L (5.09%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹26.2 L+₹4.5 L (20.8%)Rejected-Finance RZ BH 4 STREET NO 5 MAIN SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹26.4 L+₹4.7 L (21.8%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹29.2 L
EMD Value
₹58,420
Closing Date
22 Mar 2021, 6:00 pmClosed
GE (U) Elect Supply
GE U ELECTRIC SUPPLY DELHI CANTT
PROVN OF 200KVA TRANSFORMER ALONGWITH RMU FOR INTEGRATED SPORTS COMPLEX AT 35 INF BDE SHANKAR VIHAR AREA AND PROVN OF EXTERNAL ELECTRIC SUPPLY TO GYM SQUASH COURT BADMINTION COURT,VOLLEY BALL COURT TENNIS COURT AT UPPER SHANKAR VIHAR IN THE AREA OF
2021_MES_422438_1
GE ELECT/D-108/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹58,420
Yes
12 Apr 2021
23 Feb 2021
24 Mar 2021
24 Feb 2021
22 Mar 2021
10 Mar 2021
Amount
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed by engineer –in-charge.
M&L for returing filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil.
M&L for removing of excavated material n exc. 50m and depostiting where directed at a level n exc. 1.5m in soils
M & L for sand as in sand cushioning to underground PVC cable incl punning down of sand layer all as specified
S&Laying in replacement sub class B bricks having minimum compressive strenth 75 Kg/sqm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Earthing complete in replacement with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in soft/loose soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in soft/loose Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply, Laying, connecting, testing and commissioning in replacement ( including taking out existing cable) LT cable of PVC sheathed XLPE cable armoured aluminium conductor 1100 V graded , 3.5 core,50 sqmm, after taking out/down old existing unserviceable from trenches / ducks/ road crossing and poles complete all as specified and directed. NOTE : Excavation and earth work, cable protection (GI Pipe), sand filling,cable joint shall be measured and paid separately under respective items of schedule.
All as per srl item No 7 here-in-before but size of 3.5 core, 120 sqmm.
All as per srl item No 7 here-in-before but size of 3.5 core, 185 sqmm.
All as per srl item No 7 here-in-before but size of 4 core, 16 sqmm.
All as per srl item No 7 here-in-before but size of 3.5 core, 240 sqmm.
Supply , fixing and commissioning of LT Panel Out door LT Panel / LT Pillar Box of comprising of the following specification
Fabrication Details : outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2 mm thick SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 1.5 times the Rating of incommer MCCB /ACB for main Bus bar & main MCCB and out going shall be of rated capacity and all bus bar shall be support of epoxy type insulators for connecting the incoming & outgoing cables with glands , earthing of 40x6 mm GI Flat
Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps
Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T cat no WL440531OOOO or equivalent in Secure /Elmeasure
Switch Gears: (a)Incommer:- 160A 36KA,MCCB 4 pole along with sprader terminals along with sprader terminals-1no (b)Outgoing:-(i) 125A, 3 pole,36KA,MCCB along with sprader terminals along with sprader terminals-2 no's (ii) 100A,3 pole DN0 ,25 KA,MCCB along with sprader terminals along with sprader terminals-01 no (iii) 60A,3 pole DN0 ,25 KA,MCCB along with sprader terminals along with sprader terminals-01 no
Note : Rate quoted includes for necessary PCC foundation of LT pannel and includes the cost of all Accessories and switch gears
Supply , fixing and commissioning of LT Panel Out door LT Panel / LT Pillar Box of comprising of the following specification
Fabrication Details : outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2 mm thick SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm)
Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 1.5 times the Rating of incommer MCCB /ACB and out going shall be of rated capacity and bus bar shall be support of epoxy type insulators , earthing of 40x6 mm GI Flat.
Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps
Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T cat no WL440531OOOO or equivalent in Secure /Elmeasure
Switch Gears: (a)Incommer:- 400A ,50KA,MCCB 4 pole along with sprader terminals along with sprader terminals-1no (b)Outgoing:-(i) 160 A, 4 pole,36KA,MCCB along with sprader terminals along with sprader terminals-4 nos (ii) 100A,4 pole ,25 KA,MCCB along with sprader terminals along with sprader terminals-01 no
Note : Rate quoted includes for necessary PCC foundation of LT pannel and includes the cost of all Accessories and switch gears
Supplying, Errection & Fixing Steel Tubular Pole 410 SP-55 (9 metres long) complete with cast iron base plate all as specified in IS including the followings:- (a) Excavation in post holes in any types of soil up to 1.6 mtr depth from GL, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points and paid under respective items. (b) Providing PCC (1: 4:8) type D-2 using 40 mm graded stone aggregate as in foundations up to ground level all as specified and directed. (d) Providing PCC (1:2:4) type B-2 using 20 mm graded stone aggregate as in coping including necessary form work all as specified and directed. (e) Painting of Poles with one coat of red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint. Note:Earth work and PCC shall be measured under relevant Item.
Supply and fixing of out door type Street light timer Pannel/Distribution Boards with 60 A 3 pole/230 Volts contactor and Digital 24 hrs/ Analog Time Switch, 40A MCCB, Manual and Auto Mode Toggle switch cable connectors all as specified and directed. Make: indoasian Time lite /Havells / L&T
Supply and fix PVC insulated copper cable Three core of size 2.5 sqmm complete all as specified and directed.
Supply & Fix in replacement Junction/loop in - loop out box weather proof incluiding made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120 mm out side and 300x200x105 mm inside dimensions comprising of aluminium bus bar 4 strip for 3 phase and neutral 63 Amps and 02 Amps MCB SP with base incluiding embossing/ painting of danger notice of size not less than 10cm x 7.5 cm with letters,figures band conventional skull and bones in signal red colour on front face of junction box body complete all as specified and directed.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and including GI pipe 50 mm bore (medium grade) and making good both ends all specified and directed.
S&F MS Channel,Angle, Bend pipe any size for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed..
Supply and fixing of out door type Street light IP 65, class I aesthetically designed LED ensures efficient optics and Uniform distrubution of light, pressure die cast aluminium housing powder coated in graphite grey and toughned glass of system wattage 60 watt,220v 50Hz, 5kv surge protection device by removing the old defective light fitting All as specified and directed.
Supply and lay unreinforced precast concrete cable covers class HVP Type -1 with peak size 300 x 180 x 40 mm. compete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded,galvinised steel strip or wire armoured, electric power cables (heavy duty) 11000 Volt grade with stranded aluminium conductor of size 185 Sqmm 3 core complete all as specified and directed.
Supply and fix cable end jointing kit for 11 KV grade cable for indoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm complete all as specified and directed.
Supply, jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 185 Sqmm complete all as specified and directed.
Supply and installation , testing and commissioning of 11 KV, 630 Amps, 21 KA/3 sec outdoor type Ring main unit IP 54 protection plug in type extensible on one side SF 6 gas insulated one incoming and two outgoing (3 way ) with metering plate form mounted compact switch gear consisting of 02 Nos load break switch as incommer and 01 Nos outgoing VCBs , all live parts, bus bars VCB will be enclosed in robotically/manual welded minimum 2 mm thick stainless steel tank filled with SF 6 gas IP 67 Degree of protection and tested for internal arc 20 KA/1 sec as per latest IEC 62271-200 complete installed at basement of building, including the cost of PCC foundation for placing of RMU on plinth complete all as specified and directed. The unit shall include the following with all necessary standard fitting required at site:
(A) Incoming Load Break Module - 02 Nos each switching unit shall be designed as a three position switch. This three function switch combines the functions of switch disconnector and earthing switch cables switch 12 KV, 630 Amp, 21 KA - 01 Set. Snap action mechanism for motorised and manual(Both) operation with integrated earthing switch switch - 01 Nos. Cable bushing 630 Amp standard C bushing - 01. Fault passage indicator, On(N-1) load break switch where n= no of load break switch >>s/c & E/F FPI with digital display to be added for detection of cable fault. ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01. Capacitive voltage indication fixed type LED display - 01. ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. Cable box for termination of cable up to 1 No. x 185 sq.mm - 01. Cable cover standard - 01. Set of 12kV Cable Termination Boots - 01. Cable entry bottom, front - 01
(B) (i) Out going VCBs - 01 No consisting of following - function unit consist of vaccum circuit breaker in combination with a three position switch. The three position switch fulfills the operation of the disconnector function and earthing function circuits breaker unit is equipped with an over current transformer for the protection of distribution Transformer/circuit vaccum circuit breaker 12 KV, 630 A, 21 KA - 01. Spring assisted closing with stored Energy triping mechanism for motorised operation with integrated earthing switch - 01. live cable LED indicators thru capacitor voltage dividers mounted on the bushings push button for breaker trip - 01 sec O/C + E/F self powered numerical protection relay with low and High set for Over current and earth fault Relay should have facility to display the maximum loaded phase current also current also relay shall record minimum 5 fault records with time stamping - 01 Alaram trip indication 6 window anuciator for transformer faults Mechanical ON/OFF/EARTH indication -01. Auxliary contacts on load switch are 1 No+2NC & Auxiliary conract on earth switch is 1 No+ 1NC-01. Self powered electronic numerical protection relay providing 3 over-currents & 1 E/F protection - 01, shunt trip coil 24 V DC-01 capactive voltage indication fixed type LED display -01 ON/OFF/Trip mechanical indication on the front mimic of panel-01 cable box for termination boots-01. Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) Auxliary relay for transformer protection -06 Nos. (ii) Out going VCBs - 01 No, One consisting of CT 10/1 -5p10.2.5VA- 03 and other one consisting of CT 50/1 -5p10.2.5VA- 03.
(C ) Additional equipment deliverd separately or mounted seperatly, Bus connected with battery charger and battries for motor power supply-01 (i) PT ratio 11KV/3/110/v3, 100 va, 0.5 class for measurement with volts meter(ii) Auxliary transformer of 11KV/230V, 1 KVA for powering the motors and battery charger (iii ) 24 V DC battery charger and battries for motor power supply. Standard mano meter -01, Operating handle - 02 , cable clamping provision(standard)-01 Operation and maintance manual - o1, installation and commissioning manual - 01, cost of PCC works for placing RMU on plinth is deemed to be included in the cost, Height of plinth shouldnot be less than 0.45 mtrs from ground level.
NOTE :-The above module consisting of one Load break Switch and 02 VCBs shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including foundation complete.
Supply & install ,testing and commissioning of transformer step down, outdoor type copper wound 11KV/433 Volts (at no load) AC 3 phase 50 Hz 200 KVA capacity, core type, oil immersed naturally air cooled, oil natural air natural (ON AN) , with external cooling tubes/fins, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV) and having taping at +5% to 10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changergear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade crgo with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076and as per IS-1180 part - I of 2014 marked and shall comprise of the following :-
(a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer , with cable glands suitable for reception/taking out 3 core 120 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete.
(b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out 3.5 core 240 sqmm, LT 1100 volts grade, PVC/XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (c ) conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (Silica Gel). (e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, Lifting ligs,oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers. (f) One 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 of 1986 marked, filtered and tested upto 50 KV dielectric strength at 2.5 mm air gap between testing electrodes, specific resistance at 27 Degree celsius Ohm-om 500 x 10 the power12, water content 50 PPM, Dielectric dissipation factor (tan Deta at 90 degree celsius) 0.005, Neutralisation value mg of KOH/gm of oil 0.03, Inter facial tension N/M at 27 Degree celsius - 0.04, flash point 140 Degree celsius and sluge 0.1 % by weight. (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) Tranformer losses shall not exceed the loses mentioned in Table 6 of IS: 1180 of 2014 Part - I with energy Effeciency level - II.
NOTE :- The above rate includes necessary Brick masonary , PCC & RCC work for the installation of transformer as directed by Engg-Charge at site.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
mayur enterprises
MV Engineers And Contractors
M/s ELECTROSHINE ENGINEERS
Microsys Controls India
Ridhi engineers and builders
M/s Dharya Enterprises
Vijay Electricals
Buddham Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .