Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹38.3 L+₹1.2 L (3.23%)Rejected-AOC | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹40.8 L+₹3.7 L (10.1%)Rejected-AOC | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹45.9 L+₹8.8 L (23.7%)Rejected-AOC 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L4 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
4 Feb 2023, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8395 PROVN OF RAIN WATER HARVESTING AT HQ 41 ARTY DIV WADGAONSHERI AND PROVN OF CERTAIN LBW, SPECIAL REPAIRS, REVENUE WORK, MINOR WORK IN THE AREA OF AGE BR II SOUTH PUNE
2023_MES_573152_1
8395 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
183 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹92,000
27 Feb 2023
5 Jan 2023
6 Feb 2023
5 Jan 2023
4 Feb 2023
23 Jan 2023
Amount
Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating over areas, not exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating over areas, exc 1.5 m but not exc 3.0 deep and getting out Soft / disintegrated rock complete all as specified and as directed.
Excavating over areas, exc 3.00 m but not exc 4.5 deep and getting out hard rock complete all as specified and as directed.
Excavation in trenches not exc. 1.50 mtr wide & not exc. 1.50 mtr in depth for foundation or shaft, well or manholes not exc. 10 Sqm on plan and not exc. 1.50 mtr in depth and getting out in hard/dense soil complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2, using 40 mm graded stone aggregate as in foundation concrete, mass concrete etc. complete all as specified and as directed.
M&L for Loose filling with aggregates of gauge granite stone 40mm gauge in soakage pits, soakage wells complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed
Use and waste form work to soffits of suspended slab such as roof slab not exc. 200 mm thick for fair finished surfaces of concrete complete all as specified and as directed.
Use and waste of form work for edges of concrete flats, treads in floors, window cills, concrete railing, opening in concrete walls , floors and roofs n.exc. 20cm wide and sides of PCC/RCC band in wall etc. horizontal or slopping and similar work exc. 10cm but not exc. 20cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M&L for RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate in Slabs suported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like complete all as specified and as directed.
M&L for Providing precast reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate in manhole cover slab set in CM 1:6 complete all as specified and as directed.
S & F MS TMT bars 10mm dia and over, cut to length, bent to shape reqd, including cranking, bending spirally for hooping for columns and binding with mild steel annealed wire of dia not less than 0.9 mm or securing with clips complete all as specified and directed .
M&L for rendering 15mm thick in cement mortar 1:4 on brick/concrete surfaces using water proofing compound as per manufacturers instructions surface finished with sponge finish. (Note : WPC shall be measured and paid separately)
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping on top of wall, bed blocks and the like inculding weathering , slightly rounded or chamfered angles and throating as directed by Engr-in-Charge including use of necessary form work complete all as specified and directed.
S&F UPVC rectangular rainwater harvesting of size 320mm including GI/MS clamp welded to roof members corner bend, drop end stop end with all accessories complete all as specified and as directed.
S&F UPVC rectangular rainwater harvesting of size 320mm corner bend complete all as specified and as directed.
S&F UPVC rectangular rainwater harvesting of size 320mm Runner Drop complete all as specified and as directed.
S&F UPVC pipe (SCH-40) of size 100mm dia including GI/MS clamp fixed to walls with all acceceries such as bend elbow and tee etc. complete all as specified and as directed. (Note for Sr. Item No. 17 to 20 above : Rate quoted are deemed to be inclusive of necessary scaffolding / security measures as the work is to be carried out upto G+3 storey building.)
M&L for RCC pipes class NP-2 with socketed ends laid and jointed with collar complete of 200mm bore complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in bed to drain pipes including forming cradles for 200mm RCC hume pipe complete all as specified and as directed.
Returning filling in soil including spreading, levelling, watering and well ramming in layers not exc. 25cm complete all as specified and as directed
Removing excavated material not exceeding 50mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed by Engr-in-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar complete all as specified and as directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed
M&L for Mild steel bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for RCC 450mm dia concrete pipe NP3 jointed in cement mortar including necessary collar etc complete all as specified and as directed.
M&L for Cement concrete 1:3:6 bed to drain pipe including packing and haunching for 450mm dia complete all as specified and as directed.
S&F 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
M&L for 50mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed
M&L for coloured precast cement concrete interlocking paver block of glossy finish any shape and size confirming to IS-15658-2006, 60mm thick, M-35 grade with grey cement and no pigment laid over & including 25mm thick sand cushioning complete incl dismantling old tiles complete all as specified and as directed
Taking down cement or cement lime plaster on brick or stone wall etc. incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Removing excavated material not exc. 50 mtr and depositing whereas directed 50 mtr and upto a total distance of 250 mtr etc complete all as specified & directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone agg as in coping, on top of wall, bed blocks, lintel band upto 1.5 mtr span and the like including weathering, slightly rounded or chamfered angles and throating as directed by Engr-in-Charge including use of necessary form work.
M & L for preparation of new surface of any description over 10cm width or girth and applying two coats of Weather shield acrylic paint complete all as specified.
Excavation in post holes (or similar holes) each not exc 0.50 Cum getting out in soft/loose soil, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm, watering, and removing surplus soil to a distance not exc. 50 mtr and making good surfaces complete all as specified and as directed.
S & F for steel work in tubuler trusses incl special shaped washer etc complete ERW or induction butt welded tubes confirming to IS 1161-1979 garde ST 240 etc. complete all as specified & directed.
S & F roof sheeting prepainted galvalume aluminium zinc coating 150 gsm GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F roof sheeting prepainted galvalume aluminium zinc coating 150 gsm GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F joist, channel, angle Fe-410 W (Gde-E-250 quality A) fixed independently without connecting plate as in fencing post etc. complete all as specified & directed.
M&L for Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete etc. complete all as specified & directed.
M&L for Moorum/red bajari filling in floors or pavement brought from outside the MD land, laid in layers n.exc 15 cm thick spread, levelled and rammed incl watering complete all as specified and as directed.
M&L for hard core with granite or trap stone of gauge not exc 63 mm laid in layers not exc 15 cm thick incl ramming and consolidating etc. complete all as specified & directed.
M & L PCC 1:2:4 type B2(Using 40 nmm graded stone aggregate) , 125 mm thick as in flooring finished with broom finish surface laid in alternate pannels incl all necessary form work etc. complete all as specified & directed.
M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler thickness of slab 150 mm and top 30mm primed and sealed with sealing com pound, Grade ‘A’ etc. complete all as specified & directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with grade 'A' sealing compound etc. complete all as specified & directed.
Forming Construction joint 30mm deep x 10mm wide filled with 'A' sealing compound etc. complete all as specified & directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished concrete surface etc. complete all as specified & directed.
M&L for rendering 10 mm thick in CM 1:6 on brick or concrete surfaces, finished even & smooth without using extra cement etc complete all as specified & directed.
Supply only integral water proofing compound complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having OC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new wall surfaces etc complete all as specified and directed
M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) in foundation including rafts , footing, foundation beams, plinth beam etc complete all as specified and as directed.
M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for Formwork to sides of concrete foundation footing, bases of columns, plinth beams and similar works flat rough finished surface of concrete complete all as specified and as directed.
M&L for Formwork to sides of pillers, post , struts, columns and stanchions flat fair finished surface of concrete complete all as specified and as directed.
M & L for 10-15mm thick Exterior elevation stones of stone chip pattern or stone pattern as approved by Engineer-in-Charge/GE set and jointed in neat cement slurry and pointed in coloured cement to match complete over & including 10mm thick backing coat in CM 1:4 complete all as specified and as directed.
M&L for Providing Ornamental precast cement concrete type B0, 1:2:4 (12.5mm graded stone aggregate) louvers and jallies, 35-50mm thick (measured solid), including all mouldings and framework set in CM (1:6) complete all as specified and as directed.
M&L for Providing precast cement concrete type B0 1:2:4 (12.5mm graded aggregate) as in designer posts, including all mould- ings including framework set in CM (1:6) complete all as specified and directed
M&L for precast inerlocking paver blocks glossy finish with any shape and size conforming to 15658-2006, 60mm thick M-35 grade with grey cement and pigment laid over & including 25mm thick stone dust/grit complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
S & F sliding door of Jindal make or equivalent as approved aluminium powder coated section with panel of prelaminated MDF board in bottom half portion and 6mm thick glass in upper portion including standard aluminium glazing clip, fixed with screws to all slabs / wall etc including cutting, drilling and fixed in any position all as manufacturer instruction and all as directed by Engr-in-Charge. (a) Door frame - 14005 (b) Vertical rail - 19502 (c) Top rail -19503 (d) Middle rail -20060 (e) Bottom rail- 19503 (f) Glazing clips - 19352 (g) AL angle 40*25*3mm
M & L for wiring complete with 1.5 sqmm single core FRLS grade PVC insulated unsheathed,1100V grade copper multistranded conductor drawn through concealed including PVC conduit 20mm dia & PVC insulated FRLS grade copper earth continuity conductor cable 1.5sqmm connected to common earth dolly including steel terminal boxes made out of 1.2 mm thick MS sheet concealed in walls for housing the switches ,socket outlets ,fan regulators etc. all as specified for the following (Note : Rate deemed to be inclusive of cutting chases for concealed conduit 20 mm dia for wiring and making good surface of wall to the existing surface & paint of wall)
One light/fan/ point controlled by one switch and regulator.
One 3 pin 5 Amps Socket outlet point controlled by one switch on independent board.
One 3 pin 5 amps socket outlet point on same board with other switches
One 5A 3 pin socket outlet independent but below the switch board of light points in the same vertical plane .
All as per Sr. item No. 64.00 above but wiring complete with 4.0 Sqmm for 3 pin 15 Amp socket multipurpose on independent board complete all as specified and as directed.
Supply and fix switch piano flush button type 5 amps SP one way complete all as specified and as directed.
Supply and fix switch socket combination 3 pin ,15/16 A flush type complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 Pin 5 Amp flush type 240 volts complete all as specified and as directed.
Supply and fix lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F ceiling rose polycarbonate isolated body 3 ways terminals complete all as specified and as directed.
S&F in replacement of ceiling fan regulator, electronic step type, delux, ISI marked suitable for fan 48"/56" sweep complete all as specified and as directed.
Supply and fix surface and wall mounted LED batten 10 watt conforming to Cat part 112407 BCLSB 10WH of Bajaj or equivalent model in Phillips/Wipro complete all as specified and as directed.
Supply and fix surface and wall mounted LED batten light fitting of 20 watt conforming to Model :BCLSBAL 20WCW of Bajaj or equivalent model in Phillips/Wipro complete all as specified and as directed.
Supply and fixing Integral LED Security Light Luminaire 30 W comprising of epoxy powder coated aluminium housing, enclosed with polycarbonate transparent glass cover in frame suitable for 50/40 mm GI Pipe with and including 40mm dia GI pipe light grade, bracket of 1.20m length, bent to the required size and shape fixed on wall with MS clamps made out of 25x3mm flat iron & GI nut bolt complete all as specified and as directed.
Supply fix MCB DB of sheet metal enclosure double door SPN 8 way with 200 Amps rated bus bar 230 volt and including grouted in wall with PCC(1:2:4) type B-1 using 12.5mm graded stone aggregate complete all as specified and as directed.
S & F MCB SPN 415 Volts, 40-63 Amps 50 Hz, C series breaking capacity 10KA complete all as specified and directed.
S & F MCB SP 5-32Amps, 240 V,50 HZ,C series breaking capacity 10KA complete all as specified and directed
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr in deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level including connecting GI earth wire 4mm dia by GI nut, bolt, washers all as shown in electrical plate No. 3 of SSR Part I of 2009 including funnel for watering, PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in pit / chamber, RCC 1:2:4 type B0 using 12.5mm graded stone aggregates and 6mm dia mild steel bars at 100mm c/c as in chamber cover, charcoal, salt etc complete including excavation and earth work in any strata, test point and testing on completion including filling up the earth pit with black cotton soil for best result and removal of excavated material from site all as specified and directed by Engineer-in-charge. (Note : GI earthwire and GI protection pipe upto 7.5 mtr length shall be included in this item.)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 4.0Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. (Note :- Three runs of 4.0 sqmm cable and one run of PVC conduit will be measured as one unit)
Excavating in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter depth and getting out in soft/loose soil complete all as specified and as directed
Supply and fixing ceiling fans (5 Star rated) High speed working on single phase input voltage 140-285 , Sweep- 1200 mm, 350 RPM (±10%), complete with compact BLDC Motor, blades, down rods, including remote canopy and all accessories including making connections with provision of flexible wire 23 /0.0076 three core copper conductor black/ white from ceiling rose/connector to fan complete all as specified & as directed. [Make- Havells (Enticer), Orient (Aeroquiet) , Bajaj (Energos)]
S&F Exhaust fan AC single phase 240V metallic grey body of size 300mm sweep with metallic louver shutter and all fixing arrangements etc complete all as specified and directed.
M&L for laying of Reinforced concrete pipes, class NP2 with one collar per length of pipe of bore 150 mm, 2 nos half round (for bottom and top) and before laying exacavated area shall be leveling all as specified and directed Engr-in-charge.
Supply and laying XLPE Insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core complete all as specified and as directed.
Supply and fixing in replacement of GI Pipe , light grade 40 mm bore confirming to IS-1239, for cable protection on poles/ walls/ Road crossing/ floor crossing complete all as specified and as directed.
S&F LED highbay 100W Luminaire a fine ventilation technology for better thermal management and its cutting edge technology with LED 100 watt and with flat white/neutral white colour temperature etc prewired and all accessories complete all as specified and as directed.
M&L for LED post top lantern 20W, mounted on GI pipe incl grouting on gates pillar or on ground PCC 1:2:4 cast in situ of size 300mmx300mmx300mm conforming to Heritage Cat part No LPTH-20-CDL Make Crompton or of equivalent make specified here-in-after.
Supply, laying, testing and commissioning of UG LT cables of size 10 sqmm 2 Core, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS-1554 Part-I, including cable glands, cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches / ducts / under plinth floors passing through pipes etc, fixed on wall complete all as specified and as directed.
S&F distribution board sheet metal enclosure double door, factory made, fixed flush with wall inside the niches for mounting MCBs 230 volts with bus bars with front openable cover single pole and neutral 4way consumer unit complete all as specified and directed.
Supply and spreading fine dry river sand / crushed stone sand for cushioning to UG cable including spreading levelling and hand punning etc complete all as specified and directed. (Note : The punned thickness shall only be measured for payment.)
Supply and laying unreinforced precast concrete cover class LV type I, flat size 250mmx150mmx 40mm complete all as specified and as directed.
Supply and lay pipe galvanised light grade incl fittings 40mm in trenches, wall and pole all as specified and directed
Santosh Pandurang Pise
Takshashila electricals
M/s.BAJRANG CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .