Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹31.9 L+₹65,985 (2.11%)Rejected-Finance WARD NO 13 NEW SURATGARH | SURATGARH | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹34.9 L+₹3.6 L (11.5%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹36.2 L+₹5.0 L (15.9%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹37.1 L+₹5.8 L (18.5%)Rejected-Finance HOUSE NO 415 ALIKAN ROAD MANDI DABWALI SIRSA HARYANA 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
28 Feb 2023, 6:00 pmClosed
Lt Col Priyesh Srivastava
GE (AF) SURATGARH
SPECIAL REPAIR / REPLACEMENT OF MCB DBs INTERNAL WIRING ALONG WITH CONNECTED ITEMS IN BOTH DOMESTIC AND TECHNICAL AREA AT AF STN SURATGARH
2022_MES_571113_2
8022/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹97,000
Yes
7 Mar 2023
7 Feb 2023
2 Mar 2023
7 Feb 2023
28 Feb 2023
14 Feb 2023
Amount
BOQ ( SPECIAL REPAIR / REPLACEMENT OF MCB DBs INTERNAL WIRING ALONG WITH CONNECTED ITEMS IN BOTH DOMESTIC AND TECHNICAL AREA AT AF STN SURATGARH.)
Excavation in trenches not exc 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soil complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified and directed.
M&L Fazilka sand as in sand cushioning to under ground cable including punning down complete all as specified and directed. NOTE: Punning down thickness shall be measured.
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed.
Supply and fix GI tubing 40 mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position complete all as specified and directed.
Make bore to road width for providing GI pipe medium grade both end socketed for passing armoured cable complete all as specified and directed.
Taking out old unserviceable LT cable of size 10sqmm to 35sqmm 2/4/3.5 core complete all as specified and directed.
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 Sq mm 3.5 Core complete all as specified and directed.
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core complete all as specified and directed.
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sq mm 2 Core complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earthing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length ) complete all as specified and directed.
M & L for making hole in existing wall and making good the surface including neccessary cement work and matching with the existing paint complete all as specified and directed.
S & F sheet metal enclosures for Vertical MCB DB TPN 4 Way factory made IP 43 protection l double door with 200 Amp rating bus bar 415V including provision for mounting MCCB upto 125 Amps ratingcomplete all as specified and directed.
S & F sheet metal enclosures for MCB DB SPN 12 Way factory made IP 43 protection double door with 200 Amp rating bus bar 240V complete all as specified and directed.
S & F sheet metal enclosures for MCB DB SPN 8 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240V complete all as specified and directed.
S & F sheet metal enclosures for MCB DB SPN 4 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240V complete all as specified and directed.
Supply and fixing 4 Pole MCCB 63 Amps 50 Hz 415 V with rupturing capacity 16 KA with thermal setting of 80 to 100% complete all as specified and directed.
Supply and fixing 4 Pole MCCB 100 Amps 50 Hz 415 V with rupturing capacity 16 KA with thermal setting of 80 to 100% complete all as specified and directed.
Supply and fixing 4 Pole MCCB 125 Amps 50 Hz 415 V with rupturing capacity 16 KA with thermal setting of 80 to 100% complete all as specified and directed.
S&F MCBs 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.(DB will be measured and paid separately under respective items of sch A):-
MCB SPN 40 to 63 Amps.
MCB SP 5 to 40 Amps
M & L for point wiring (surface) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 2.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 2.5 Sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by Engr-in-charge.
S & F Socket outlet 2 in 1, 3 pin, 16 amps, flush type, 240 volts complete all as specified and directed.
S & F switch piano flush button single pole one way 16 amp 240 volts, complete all as specified and directed.
Supply and fixing post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing 8 Watt LED Ballard light New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source Complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable 4Sqmm x 2 core PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed one twin core cable flat or circular complete all as specified and directed.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Rewinding of single phase/three phase AC 1 HP/2HP copper wound electric motor with super enamelled copper winding wire of existing size as per manufacturers, including allied insulating material ,complete all as specified and directed
Disconnecting opening of Gear Box of any description and any make for Repair/replacement of unserviceable /defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the Gear Box after overhauling/servicing and its testing complete all as specified and directed.
Disconnecting opening of Driver of existing make & model for repair/replacement of unserviceable /defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the Driver panel after overhauling/servicing and its testing complete all as specified and directed.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
AGGARSAIN BUILDERS
M. S. CONTRACTOR
M/s JUGAL KISHORE MISHRA AND SONS
SIGMA ENGINEERS AND CONTRACTORS
AJAY ELECTRIC COMPANY
Gupta Suppliers
SRI SAI CONSTRUCTION COMPANY
SHARMA CONSTRUCATION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .