Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
27 Sept 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC CHITRAKOOT
Dwarikapuri Purani Bazar Karwi Chitrakoot
Work of installation and capacity increase of additional transformers of different capacities of 11/0.4 KVA Under EDD-Rajapur
2023_DVVNL_841897_1
19/SE/EDCCKT/2023-24
Open Tender
Electrical Works
Piece-work
90 days
KARWI CHITRAKOOT
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
www.dvvnl.org
₹15,000
3 Oct 2023
22 Sept 2023
27 Sept 2023
22 Sept 2023
27 Sept 2023
22 Sept 2023
Amount
Cartage of Pole & material from store centre from any other place to the respective site of work through the Kachha Pacca road inclading the work of its loading & unloading at the respective ends also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work.
PCC Pole 8.5 Mtr Long
Safe cartage of line material viz. conductor, cable, GI earth wire, cross arm, angle, channel, insulator, clamps and other line material from store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of dragging.
25 KVA 11/0.4KV Distribution Transformer
63 KVA 11/0.4KV Distribution Transformer
100 KVA 11/0.4KV Distribution Transformer
250 KVA 11/0.4KV Distribution Transformer
400 KVA 11/0.4KV Distribution Transformer
Erection of 8.5 Mtr. Single PCC Pole including complete. H.T/L.T fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of 8.5 Mtr. Single PCC Pole per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Double-Pole for 25/63/100 KVA T/F including complete. H.T/L.T fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Double-Pole for 25/63/100 KVA T/F per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Top Channel with clamp as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of M.S. Base Angle with clamp (65X65X6X2028mm) For T/f as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Ms Dropper Channel(100X50X5X2028mm) with clamp as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection and Grouting of Stay set Complete including the work of nozelling etc. as per RESPO manual and also including the cost of all grouting material, labour, T&P etc required for proper completion of work.
Fixing & Commisioning of T-off Channel with clamp as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of EYE BOLT FOR SERVICE CABLE as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of M.S. ANGLE ( 75X75X6X2098 SQ MM) as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of 11 KV T.P.M.O. SWITCH SET as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of DANGER BOARD WITH CLAMP as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of COPPER L-PIECE 62X225X12 MM as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of ALUMINIUM LUG LONG 400 SQ MM as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
PIPE EARTHING OF TRANSFORMER BY 2 DIA 6 METER LENGTH G.I. PIPE (BODY+NETURAL) (All Material arrenge By Contractor)
Fixing & Commisioning of 4 CORE LT MCB WITH BOX as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Laying, Sagging and Binding & Jumpring of ACSR weasel conductor as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Laying, Sagging and Binding & Jumpring of NEUTRAL CUM EARTH WIRE as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Laying, Sagging and Binding & Jumpring of Phase wire Weasel ACSR with 3% Sag as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Fixing & Commisioning of Earthing Rod Complete as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of 11 KV Fuse Set as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of DISTRIBUTION BOX as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Laying, Sagging and Binding & Jumpring of LT PVC Cable 3.5X150 as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Laying, Sagging and Binding & Jumpring of 10/16 SQ MM SINGLE CORE PVC CABLE as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Laying, Sagging and Binding & Jumpring of AB Cable (95X3+1X70+1X16mm) as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Laying, Sagging and Binding & Jumpring of LT PVC Cable AL1X400 Sqmm as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Fixing & Commisioning of Installation of 25 KVA 11/0.4KV Distribution Transformer as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Installation of 63 KVA 11/0.4KV Distribution Transformer as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Installation of 100 KVA 11/0.4KV Distribution Transformer as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Installation of 250 KVA 11/0.4KV Distribution Transformer as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Installation of 400 KVA 11/0.4KV Distribution Transformer as per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Construction of new 250/400 KVA T/F Plinth & Francing including of first class brick sand cement etc. As per RESSPO manual (all Civil material shall be arranged by contractor)
Repairing of Old Plinth & Francing including of first class brick sand cement etc. As per RESSPO manual (all Civil material shall be arranged by contractor)
Dismentling of 100KVA/250 KVA from old site including the cost of labour, T&P carrier etc required for proper completion of work.
Strengting of tilted pole
Tree looping & chooping
VERMA ELECTRICAL AND CONSTRUCTION CO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .