| 1 | L-1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L-1 | Accepted-AOC The work has been Completed
BANK GUARANTEE HAS BEEN SUBMITTED IN OFFICE |
| 2 | L-2₹1.6 Cr+₹1.0 L (0.64%)Accepted-AOC | ₹1.6 Cr+₹1.0 L (0.64%) | L-2 | Accepted-AOC The work has been Completed
BANK GUARANTEE HAS BEEN SUBMITTED IN OFFICE |
| 3 | L-3₹1.6 Cr+₹1.1 L (0.68%)Accepted-AOC C 16 HIG C SECTOR AYODHYA NAGAR BHOPAL MP 462041 | BHOPAL | BHOPAL | MADHYA PRADESH | 462041 | ₹1.6 Cr+₹1.1 L (0.68%) | L-3 | Accepted-AOC The work has been Completed
BANK GUARANTEE HAS BEEN SUBMITTED IN OFFICE |
Tender Value
₹1.6 Cr
EMD Value
₹1.6 L
Closing Date
12 Apr 2022, 5:30 pmClosed
P K JAIN
ISBT, Electric Section
Internal electrification works at Offices and Buildings of BMC in Govindpura,Narela,Huzur and Madhya vidhan sabha under BMC. (On Empanelment Basis)
2022_UAD_190160_1
2020205528
Open Tender
Electrical Works
Item Rate
365 days
ISBT, Electric Section
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹12,500
₹1.6 L
17 Mar 2023
11 Mar 2022
13 Apr 2022
11 Mar 2022
12 Apr 2022
11 Mar 2022
Amount
Internal electrification works at Offices and Buildings of BMC in Govindpura,Narela,Huzur and Madhya vidhan sabha under BMC. (On Empanelment Basis)
4000000711-Dismantling and shifting of window air Dismantling& shifting of window air conditioning unit 1.0TR/ 1.5TR/2TR capacity excluding fascia and cutting, welding complete work as required within town.
4000000712-Dismantling and shifting Dismantling &shifting, installation, testing & commissioning of split air conditioning unit 1.0TR/1.5TR/2TRcapacity including indoor / outdoor unit complete as required within town.
4000000713-Copper tube 1/4" Supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required. Copper tube 1/4" (AS PER PWD SOR - 2020)
4000000715-Copper tube 3/8" Supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required. Copper tube 3/8" (AS PER PWD SOR - 2020)
4000000716-Copper tube 1/2" Supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required. Copper tube 1/2" (AS PER PWD SOR - 2020)
4000000717- Copper tube 5/8" Supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required. Copper tube 5/8" (AS PER PWD SOR - 2020)
4000000718- Chemical servicing Chemical servicing of window/split air conditioning unit 1TR/1.5TR/2TR/3TR capacity including cleaning of cooling & condensing units, filters, grills etc & all other parts oiling & greasing of fan motor, testing of A.C unit etc. (AS PER PWD SOR - 2020)
4000000719-Gas charging 1.0 TR Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any. 1.0 TR (AS PER PWD SOR - 2020)
4000000720-Gas charging 1.5 TR Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any. 1.5 TR (AS PER PWD SOR - 2020)
4000000721-Gas charging 2.0 TR Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any. 2.0 TR (AS PER PWD SOR - 2020)
4000000722-Gas charging 3.0 TR Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any. 3.0 TR (AS PER PWD SOR - 2020)
4000000723-Tube light LED 1 X 18W Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD <(><<)> 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106(2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 18Watt, Integral i/c batten aluminium body, PC diffuser. (AS PER PWD SOR - 2020)
4000000724-Tube light LED 1 X 20/22Watt Supply and fixing Led tube rod comprising of LED tube with non- integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD <(><<)> 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser. (AS PER PWD SOR - 2020)
4000000725-LED retrofit glass tube Supply and fixing Led tube rod comprising of LED tube with non- integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD <(> <<)> 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED retrofit glass tube i/c driver only 20/22Watt,color temp 3000 - 6000K without box suitable for replacing existing 36/40Watt FTL (AS PER PWD SOR - 2020)
4000000726-2' X 2', 36W, 3000-6500k Supply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF> 0.95, THD <(><<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 36Watt, color temp 3000- 6500k as required. (AS PER PWD SOR - 2020)
4000000727-2' X 2', 45W, 3000-6500k Supply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF> 0.95, THD <(><<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 45Watt, color temp 3000- 6500k as required. (AS PER PWD SOR - 2020)
4000000728-LED luminiare 2' X 2', 36W, 3000-6500k Supply and fixing of surface mounting type LED light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver, PF> 0.95, THD <(><<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 36Watt, color temp 3000- 6500k as required. (AS PER PWD SOR - 2020)
4000000729-LED luminiare 2' X 2', 45W, 3000-6500k Supply and fixing of surface mounting type LED light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver, PF> 0.95, THD <(><<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 45Watt, color temp 3000- 6500k as required. (AS PER PWD SOR - 2020)
4000000730-3 Watt, color temp 3000-6500k as require Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD <(><<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. 3 Watt, color temp 3000-6500k as required.(AS PER PWD SOR - 2020)
4000000731-14/15 Watt, color temp 3000-6500k as req Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD <(><<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. 14/15 Watt, color temp 3000- 6500k as required. (AS PER PWD SOR - 2020)
4000000732-18/20Watt, color temp 3000-6500k as requ Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD <(><<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. 18/20Watt, color temp 3000-6500k as required. (AS PER PWD SOR - 2020)
4000000733- 22/24Watt, color temp 3000-6500k as req Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD <(><<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. 22/24Watt, color temp 3000-6500k as required. (AS PER PWD SOR - 2020)
4000000734-3 Watt, color temp 3000-6500k as require lSupply and fixing surface mounting LED down lighter, LED of 1 to 3Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD <(> <<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. 3 Watt, color temp 3000-6500k as required. (AS PER PWD SOR - 2020)
4000000735-14/15 Watt, color temp 3000-6500k as req Supply and fixing surface mounting LED down lighter, LED of 1 to 3Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD <(> <<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. 14/15 Watt, color temp 3000- 6500k as required. (AS PER PWD SOR - 2020)
4000000736-18/20 Watt, color temp 3000-6500k as req Supply and fixing surface mounting LED down lighter, LED of 1 to 3Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD <(> <<)> 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. 18/20 Watt, color temp 3000- 6500k as required. (AS PER PWD SOR - 2020)
4000000737-2.5 sq. mm. Armoured 2 core Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 2 core 2.5 sq. mm. (AS PER PWD SOR - 2020)
4000000738-Armoured 2 core 4 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 2 core 4 sq. mm. (AS PER PWD SOR - 2020)
4000000739-Armoured 2 core 6 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 2 core 6 sq. mm. (AS PER PWD SOR - 2020)
4000000740-Armoured 2 core 10 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 2 core 10 sq. mm. (AS PER PWD SOR - 2020)
4000000741-Armoured 3 core 2.5 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 3 core 2.5 sq. mm. (AS PER PWD SOR - 2020)
4000000742- Armoured 3 core 4 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 3 core 4 sq. mm. (AS PER PWD SOR - 2020)
4000000743-Armoured 3 core 6 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 3 core 6 sq. mm. (AS PER PWD SOR - 2020)
4000000744-Armoured 3 core 10 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 3 core 10 sq. mm. (AS PER PWD SOR - 2020)
4000000745-Armoured 4 core 1.5 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 4 core 1.5 sq. mm. (AS PER PWD SOR - 2020)
4000000746- Armoured 4 core 2.5 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 4 core 2.5 sq. mm. (AS PER PWD SOR - 2020)
4000000747- Armoured 4 core 4 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 4 core 4 sq. mm. (AS PER PWD SOR - 2020)
4000000748- Armoured 4 core 6 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 4 core 6 sq. mm. (AS PER PWD SOR - 2020)
4000000749-Armoured 4 core 10 sq. mm. Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 4 core 10 sq. mm. (AS PER PWD SOR - 2020)
4000000750-1.0 TR star rating 3 star SPLIT AC (inverter model) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to 50 deg. C & heating within 0 deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). SPLIT AC (inverter model, Cooling only) 1.0 TR star rating 3 star (AS PER PWD SOR - 2020)
4000000751-1.5 TR star rating 3 star SPLIT AC (inverter model) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to 50 deg. C & heating within 0 deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). SPLIT AC (inverter model, Cooling only) 1.5 TR star rating 3 star (AS PER PWD SOR - 2020)
4000000752-1.8/2 TR star rating 3 star SPLIT AC (inverter model) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to 50 deg. C & heating within 0 deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). SPLIT AC (inverter model, Cooling only) 1.8/2 TR star rating 3 star (AS PER PWD SOR - 2020)
4000000753-1.8 TR/2.0 TR single phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt drain pump & decorative panels. 1.8 TR/2.0 TR single phase (AS PER PWD SOR - 2020)
4000000754-2.4 TR single phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt drain pump & decorative panels. 2.4 TR single phase (AS PER PWD SOR - 2020)
4000000755-2.7/3.0 TR three phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).Ceiling suspended/mounted cassette type 4 way unit with inbuilt drain pump & decorative panels. 2.7/3.0 TR three phase (AS PER PWD SOR - 2020)
4000000756-2.0 TR/2.4 TR single phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand). Floor standing/slim line 2.0 TR/2.4 TR single phase (AS PER PWD SOR - 2020)
4000000757-3.0TR/3.3 TR three phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand). Floor standing/slim line. 3.0TR/3.3 TR three phase (AS PER PWD SOR - 2020)
4000000758-3.8TR/4.0 TR three phase Cassette AC :- Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand). Floor standing/slim line 3.8TR/4.0 TR three phase (AS PER PWD SOR - 2020)
1000003073-Water Cooler 80 Letter Water Cooler Storage Cap 80 Letter Cooling Cap 80 Letter. (Blue Star, Voltas Make).
1000010453-fabricated stand Providing ,fixing, testing, commissioning of fabricated stand for RO machine as per requirement as site complete in all respect.
3000008848-RO with All Required Accessories Supply and Installation of RO with All Required Accessories
4000000759-LED Luminiare 1'x1', 24W Panel Driver Supplying Fixing and testing of approved and suitable make LED driver for an existing LED luminary panel. LED Luminiare 1'x1', 24W Panel Driver (AS PER PWD SOR - 2020
4000000760- 24Watt to 25Watt, color temp 3000-6500k Supplying fixing and testing of approved and suitable make LED driver/moduler for an existing LED street light/Flood light. 24Watt to 25Watt, color temp 3000-6500k As Standard PWD
4000000761- 60Watt, color temp 3000-6500k Supplying fixing and testing of approved and suitable make LED driver/moduler for an existing LED street light/Flood light. 60Watt, color temp 3000-6500k As Standard PWD
4000000762-90Watt, color temp 3000-6500k Supplying fixing and testing of approved and suitable make LED driver/moduler for an existing LED street light/Flood light. 90Watt, color temp 3000-6500k As Standard PWD
4000000763-120Watt, color temp 3000-6500k Supplying fixing and testing of approved and suitable make LED driver/moduler for an existing LED street light/Flood light. 120Watt, color temp 3000-6500k As Standard PWD
Bidder Name
Amount
HEERA LAL GOUR(GSTN-23ARFPG1306F1ZK)
NAMAN SHRIVASTAVA CONTRACTOR(GSTN-23CWTPS1978N1ZF)
MAA SHARDA ELECTRICALS(GSTN-23BHVPG8485Q2Z6)
NAMAN SHRIVASTAVA CONTRACTOR
MAA SHARDA ELECTRICALS
HEERA LAL GOUR
NAMAN SHRIVASTAVA CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .