Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC WARD NO 07 WARD NO 07 THANA PARA NALHATI BIRBHUM WEST BENGAL 731243 | BIRBHUM | WEST BENGAL | 731243 | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹10.4 L+₹1.7 L (20.0%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹10.6 L+₹2.0 L (22.6%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹10.9 L+₹2.2 L (25.3%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L4 | Rejected-Finance HIGH RATE |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
20 Jul 2020, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF SINGARSI
AGE I AF SINGARSI
Repair Maint of internal wiring MCBs DBs with light fittings in tech area at AF Stn Singarsi under AGEI AF Singarsi.
2020_MES_357535_1
C/8480/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹17,000
Yes
17 Aug 2020
1 Jul 2020
21 Jul 2020
2 Jul 2020
20 Jul 2020
6 Jul 2020
30 days
Amount
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
M&L for point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm (FRLS) in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of 1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm (FRLS) PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete all as specified and directed by engineer incharge.
All as per item No.2 here-in-before but one 3pin switch socket outlet 5A on independent board complete all as specified and directed by engineer incharge.
All as per item No.2 here in before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by engineer incharge.
All as per item No. 2 here-in-before but using 2.5 sqmm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board complete all as specified and directed by engineer incharge.
Supply & fix switch piano flush type, single pole one way, 5 Amp complete.
Supply and fix bell push switch, flush type 5 Amp complete.
Supply & fix switch socket combination multipurpose 2 in 1, 3 pin 5 Amp flush type complete all as specified and directed by engineer incharge.
Supply & fix switch socket combination multi - purpose 3,5 pin, 15 amp and , 5 amp controlled by one switch flush type complete.
S&F socket out let 2 in 1 3 pin 5 Amps flush type cmplete all as specified and directed by Engr-in- charge.
S & F call bell, ding dong AC 230 volts, single pole complete.
S & F ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed.
Taking down unserviceable rusted / damaged MCB DB of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
S & F SPN DB made up with sheet metal Double Door, phosphorised, power coated, neutral link, earth bar and din rail, 6 way with 200 amps rated bus bar, 240 volts including taking down old one and making good the distrubed surface matching with existing surface complete all as specified and as directed.(Make: Siemens cat pt No: 8GB32102RC06 or Equivalent Hager).
All as per item No. 14 above but 8 way, 240 volts.(Make: Siemens cat pt No: 8GB32102RC08 or Equivalent Hager)
All as per item No: 14 here-in-before but TPN DB 6 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed.(Make Havells Cat No: DHDPTHODPW06/Siemens/Hager)
M&L for MCB, TPN,63 Amps,240 V, and ‘C’ series breaking capacity 15 KA complete all as specified and directed by Engr-in-charge.
All as per item No: 14 here-in-before but Vertical TPN DB 8 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed.(Make Havells Cat No: DHDMTVOSRW08/Siemens/Hager)
M&L for MCCB, 3P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 25KA complete.
M&L for MCB, SPN, 240 V, 40 Amps, and ‘C’ series breaking capacity 10 KA complete all as specified and directed by Engr-in-charge.
M&L for MCB, SPN, 240 V, 20 to 32 Amps, and ‘C’ series breaking capacity 10 KA complete all as specified and directed by Engr-in-charge.
M&L for MCB, SP, 240V, 10 to 32 Amps and ' C ' series breaking capacity 10 KA complete all as specified and directed by Engr-in-charge.
Supply and fix ceiling fan regulator electronic Step type, solid state, 100W, 240 volts, complete all as specified and as directed.
Supply and fixing lamp holder PVC/poly carbonate with back plate suitable for batten fittings
Supply and fixing in replacement of existing energy efficient tube light fitting of capacity 28/18 W suspended / wall mounted type complete convet to LED fitting 20 Watt and copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length complete all as specified and as directed of Make :Crompton BRIGHT LINEA cat No: CCS-100-20-65-HL2-DP-NWH or equivalent to Bajaj,Havells
Supply and fix AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA DP MCB, one 25 Amps socket and one 25 Amps plug top prewired of complete as specified after taking out old unserviceable starter unit all as directed.
Supply and fixing sub main wiring with two run of single core 2.5 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 1.5 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping all as specified and as directed. Note : (i) Two run of single core cable 2.5 sq mm and one run earth wire 1.5 sq mm will be measured as one length.
Supply and fixing sub main wiring with two run of single core 4 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through Steel conduit (med Grade) with all fittings including 2.5 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping all as specified and as directed. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 2.5 sq mm will be measured as one length.
Supply and fixing sub main wiring with two run of single core 4 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 2.5 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping all as specified and as directed. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 2.5 sq mm will be measured as one length.
Supply and fixing sub main wiring with two run of single core 6 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 4 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping all as specified and as directed. Note : (i) Two run of single core cable 6 sq mm and one run earth wire 4 sq mm will be measured as one length.
S&F for 36 W (2'X2') , LED Recessed full lit luminarie with glare free uniform illumination with longer life and less maintenance , Environmental friendly, new generation, aesthetically designed, ultra modern with high brightness SMD LED lamp as light source , suitable for Armstrong /Grid ceiling etc pre-wired complete with fixture after taking down old one all as specified and directed by Engr-in-charge.Make : Crompton ,Cat No- LCTLRNE-36-FO-WW or equivalent of Phillips,Bajaj
S&F for 36 W Aura - II is edge lit 1ft X 4 ft slim panel perfect for hospitals,offices,classrooms, and any other work space requiring high quality ambient lighting Recess mounting light fitting , Environmental friendly, new generation, aesthetically designed, ultra modern with high brightness SMD LED lamp as light source , suitable for Armstrong /Grid ceiling etc pre-wired complete with fixture size (4ft X1 ft) all as specified and directed by Engr-in-charge. Make : Crompton ,Cat No- AURA -II CCR- 132-36-57-SL-NWH or equivalent of Phillips,Bajaj.
Materials and labour for earthing complete withGalvanised steel earth plate electrode 60x60x6.3 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel,GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed .
S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush mounting enclosure with 2 pin earth plug socket complete all as directed.
S&F for 25 watt LED Building security light fitting of new generation energy saving and enviornmental friendly long life pressure dia-cast aluminium road way luminarie with high power LED lamp as light source and electronic driver etc pre-wired complete all as specified and directed by Engr-in-charge (Make Baja item code 830318 or equivalent to Havells, crompton)
M/S Subhadip Enterprise
M/S AMARNATH AGARWALLA
M/S MBS TRADING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .