Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.0 L+₹1.6 L (5.41%)Rejected-Finance | L2 | Rejected-Finance Being Other Than Lowest | |
| 3 | L3₹34.3 L+₹4.9 L (16.6%)Rejected-Finance | L3 | Rejected-Finance Being Other Than Lowest | |
| 4 | L4₹35.3 L+₹5.9 L (20.2%)Rejected-Finance | L4 | Rejected-Finance Being Other Than Lowest | |
| 5 | L5₹38.9 L+₹9.5 L (32.3%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L5 | Rejected-Finance Being Other Than Lowest |
Tender Value
₹21.4 L
EMD Value
₹42,860
Closing Date
26 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
CERTAIN E/M MAINT WORKS AT DGNCC CAMP UNDER GE (EAST) DELHI CANTT-10
2022_MES_539975_1
GE/DE-28/2022-23
Open Tender
Civil Works
Item Rate
120 days
GE (EAST) DELHI CANTT-10
Class E cat b (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹42,860
Yes
17 Sept 2022
22 Jul 2022
30 Aug 2022
22 Jul 2022
26 Aug 2022
12 Aug 2022
Amount
Taking down/ out carefully copper/aluminium point wiring for light/ fan/ bell/ sockets 5/15 Amps complete without accessories as switches, Sockets, holders, ceiling roses, light fitting regulators etc (to be measured separately) and making good the disturbed surface all as directed.
M&L for point wiring with single core fire retardant low smoke PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) connected to common earth dolly and drawing through existing surface/concealed conduit pipe and in existing MS box/modular box covered with existing hylem sheet / modular plate (top cover) for mounting switches, sockets or fan regulators etc for the following :-
One light point/ fan point/ bell point controlled by one switch
One socket outlet 5 Amps controlled by one switch on same board
One socket outlet 5 amps controlled by one switch on independent board
All as per item No.2 here in before but wiring with 2.5sqmm copper wire and 2.5sqmm earth wire for socket out let on independent board.
S&F in repair switch piano flush type, 6 amps one way,SP,230 volts AC all as directed.
S&F in repair switch piano flush type, 16 amps one way,SP,230 volts AC all as directed.
S&F in repair socket outlet 6 amps 5 pin , all as directed.
S&F in repair socket outlet 6&16 amps 6 pin all as directed.
S&F in repair modular switch flush type, 6 amps one way,SP,230 volts AC all as directed.
S&F in repair modular switch flush type, 16 amps one way,SP,230 volts AC all as directed.
S&F in repair modular switch bell push flush type, 6 amps one way,SP,230 volts AC all as directed.
S&F in repair modular socket outlet 6 amps 5 pin 2 module all as directed.
S&F in repair modular socket outlet 6 & 16 amps 6 pin multipurpose combined 2 module all as directed.
S&F in repair modular Step Fan regulator, 120 watts single / double module all as directed.
S&F in repair Modular white cover plate with frame 1 module all as directed
S&F in repair Modular white cover plate with frame 2 module all as directed
S&F in repair Modular white cover plate with frame 3 module all as directed
S&F in repair Modular white cover plate with frame 4 module all as directed
S&F in repair Modular white cover plate with frame 6 module all as directed
S&F in repair Modular white cover plate with frame 12 module all as directed
S&F in repair Modular Metal Flush Box 1/2 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 3 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 4 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 6 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
S&F in repair Modular Metal Flush Box 12 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and as directed
Supply and fixing in replacement of lamp holder PVC/ Polycarbonate type insulated body with back plate suitable for batten fittings complete all as specifed and as directed. Make : Anchor/SSK/Cona.
Supply and fixing in replacement of Ceiling rose, insulated body, 3 terminal, 240 volts complete all as specified and as directed.
Supply and fixing in replacement of electric bell of DINGDONG type, 6 Amps, 240 volts, single pole and making all necessary connections complete all as directed.
Material and labour for replacement of submain wiring complete with 2 x 4.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 4 sqmm( same specification ) as earth wire in existing PVC conduit complete all as directed.
Material and labour for replacement of submain wiring complete with 2 x 10.0 sqmm (nominal area) FR, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 10 sqmm( same specification ) as earth wire in existing PVC conduit complete all as directed.
Supply and fixing in replacement of MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed.
Supply and fixing in replacement of MCB C Curve type, 10 kA, 40Amp, Single Pole with over load and short circuit protection complete all as directed.
Supply and fixing in replacement of MCB SPN C Curve type, 10 kA, 40 Amp, with over load and short circuit protection complete all as directed. .
All as srl item No 32 here in before but of 32 amps capacity and TPN type.
Supply and fixing in replacement of Modular AC Socket with 25 Amps SP mini MCB, 230 Volts, 50Hz. In 4 module sheet metal enclosure complete all as specified and as directed.
Supply and fixing of PVC casing & caping ( ISI marked) 20 mm width double lock type inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories such as couples,Pvc Rawal Plugs, saddles, etc complete all as directed.
Supply and fixing of PVC casing & caping ( ISI marked) 25 mm width double lock type inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories such as couples,Pvc Rawal Plugs, saddles, etc complete all as directed.
S&F in replacement of rigid non metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete surface mounted / concealed and making good the surface all as specified and and as directed.
Supply and fixing in replacement of wall light fitting comet type suitable for LED lamp complete all as directed
S & F in replacement LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 20 Watts, cool/warm white as per site requirement complete all as specified and directed.
S & F in replacement of LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 10 Watts, cool/warm white as per site requirement complete all as specified and directed
S&F in replacement of bulk head fitting 9/10W W with PMMA diffuser complete all as specified and directed.
Supply and fixing in replacement of LED ceiling light fitting 15 watt, in round shape, surface/recess type cool/warm white with inbuilt driver as per site requirement and making all electric connections complete all as directed.
S & F in replacement of energy efficient LED fittings 45W LED suitable for building security light pressure die cast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as directed.
Supply and fixing in replacement of area lighting LED flood fitting 120W complete all as specified and as directed.
Supply and fixing in replacement of street light fitting bracket, 1.0 mtr long made out of galvanized iron pipe of 32 mm dia size light grade complete with nut, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed.
Supply and fixing in replacement of Ventilating fan 250 mm sweep plastic body type including self cosing louver and making all electric connections and depositing old U/S complete all as directed.
Supply and fixing in replacement of Ventilating fan 300 mm sweep plastic body type including self cosing louver and making all electric connections and depositing old U/S item complete all as directed.
Supply and fixing in replacement of Wall Mounted Fan 400 mm sweep plastic body type including making all electric connections and depositing the old U/S item complete all as directed.
Supply and fixing exhaust fan upto 300 mm sweep metalic body type and making all electric connections complete all as directed and depositing the old U/s item.
Supply and fixing exhaust fan upto 450 mm sweep metalic body type and making all electric connections complete all as directed and depositing the old U/s item .
S&F Steel fastneer of 4" long and 8mm dia with Nuts & washer complete all as specified and as directed.
S & F in replacement of MCCB, 415 volts, three pole of cap 125 Amps, 16 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including necessary spreader / thimbles of suitable size and making connections complete all as directed.
S & F in replacement of MCCB, 415 volts, three pole of cap 160 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including necessary spreader / thimbles of suitable size and making connections complete all as directed.
S & F in replacement of aluminium cable 1100 Volt grade, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable circular of size 6 Sqmm ISI marked in service connections, including taking down old unserviceble cable complete all as directed.
S & F in replacement of plug top 3 pin 10/20 amp earth metal clad suitable for industrial type DB complete all as directed.
S & F in replacement of socket 3 pin 10/20 amp earth metal clad suitable for industrial type DB complete all as directed.
S&F PVC top, 3 pin 15 Amps, 230 Volts, 50 Hz.
S&F in replacement of Recess/Surface mounting 2x2 square flat panel ultra slim scoop LED light 36 W warm/cool white with driver/transformer etc suitable for Grid ceiling/Gypsum board/POP ceiling incl making electric connection complete as as directed.
Supply and fixing in replacement of 'T' cover Bakelite sheet 2 mm thick in round shape complete all as specified.
Supply and fixing in replacement of Bakelite sheet 3mm thick of size 5"x5" duly wire cut for switches, sockets, regulator etc as per site requirement as directed.
S&F in replacement of Bakelite sheet 3mm thick of size 8"x5" duly wire cut for switches, sockets, regulator etc as per site requirement as directed.
S&F in replacement of Bakelite sheet 3mm thick of size 8"x10"duly wire cut for switches, sockets, regulator etc as per site requirement all as directed.
S&F in replacement of Bakelite sheet 3mm thick of size 10"x12" duly wire cut for switches, sockets, regulator etc as per site requirement all as directed.
Taking down old unserviceable LT U/G cable any size and core complete all as specified.
S&F XLPE insulated armoured heavy duty U/G aluminium conductor cable served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and overall PVC sheathed of size 10 Sqmm 2 core.
All as per item sl No 65 but 16 sqmm, 2 core.
All as per item sl No 65 but 16 sqmm, 4 core.
All as per item sl No 65 but 25 sqmm, 4 core.
All as per item sl No 65 but 50 sqmm, 3 1/2 core.
Excavation in trenches in soft / loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides complete all as directed.
Material and labour for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as directed.
Removal of excavated material n exc 50m and depositing n exc 1.5m above starting point complete all as specified and as directed..
S&F of MCB DB conforming to IP 43 - IK 09 with double door, SPN 08 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces.
S&F of MCB DB conforming to IP 43 - IK 09 with single door, SPN 04 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces.
Supply and fixing in replacement of MCCB incommer Distribution Board ( Vertical Load line DB) double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connections and taking out the old unserviceable DB complete all as directed.
Supply and fixing of Geyser 50 ltre capacity vertical type with steel tank and glass inner linen , 5 star rating complete including taking down the old u/s geyser and depositing to DGNCC complete all as specifed and directed.
Supply and fixing in replacement of heating element 1.5/2 KW capacity round/triangular type for geyser of any type/Make and capacity including making necessary electric connections and testing the geyser complete all as directed. Note : The petty items such as nut, bolt, clamps etc are deemed to be included in quoted rates.
Supply and fixing in replacement of heating element 6 KW capacity for Solar cum electric heater water tank / electric boiler of any type/Make and capacity including making necessary electric connections and testing the complete all as directed. Note : The petty items such as nut, bolt, clamps etc are deemed to be included in quoted rates.
Supply and fixing in replacement of heating element 9 KW capacity for Solar cum electric heater water tank / electric boiler of any type/Make and capacity including making necessary electric connections and testing the complete all as directed. Note : The petty items such as nut, bolt, clamps etc are deemed to be included in quoted rates.
Supply and fixing in replacement of thermostat ISI marked for geyser of any type/Make and capacity as per sample, including making necessary electric connections and testing the geyser complete all as directed.
M &L in replacement of base plate assembly of 6/9 holes suitable for fixing on a geyser tank 25/35/50 Ltr capacity incl Nuts & rubber packing for water tight joint complete all as specified and directed.
Supply and fixing in replacement of steel wired connection 600mm long and C P brass adopter 10 mm dia with washer for geyser of any type/Make and capacity complete all as directed.
Supply and fixing in replacement of indicator lamp red/green suitable for geyser of any type/Make and capacity including making necessary electric connections and testing complete all as directed.
Supply and fixing in replacement of LED bulbs 9W, B 22/E14/E27 90-300V AC-50 Hz, complete all as specified and as directed.
Supply and fixing in replacement of LED Halogen light fitting 50 W, AC 230V, 50 Hz, complete all as specified and as directed.
Supply and fixing in replacement of LED Dimmer light 400W, AC 230V, 50 Hz, acomplete all as specified and as directed.
Supply and fixing in replacement of Halogen lamp -,500W, AC 230V, 50 Hz, complete all as specified and as directed.
Supply and fixing in replacement of Halogen lamp -,1000 W, AC 230V, 50 Hz, complete all as specified and as directed.
Supply only cable pvc single core unsheathed copper conductor stranded 1.5 sqmm complete all as specified and as directed
Supply only cable pvc single core unsheathed copper conductor stranded 2.5 sqmm complete all as specified and as directed
Supply only cable pvc single core unsheathed copper conductor stranded 4 sqmm complete all as specified and as directed
Supply only cable pvc flexible twin core copper conductor twisted 23/76 complete all as specified and as directed
Supply only cable pvc insulated copper conductor 3 core 4 sqmm copper conducter pvc sheathed circular complete all as specified and as directed
Maintenance and safe custody of electrical system by providing minor items like washers, gasket, small pieces of wires, fuses etc and detecting faults & rectifying and making electric supply functional round the clock by providing the following for camp: a) Electrician - 03 Nos (One electrician each shift) b) Helper - 03 Nos ( One per shift) (Note: (1). The contractor shall provide all T & P, ladder, Scaffolding, Safety measures etc and rate shall be deemed to be included for the same and in case of absence of electrician/helper in each shift, recovery @ 1000/- per shift shall be made out of payment due for electrician/helper whoever is absent. (2). Attendence register shall be maintain for the entire period and the same shall be signed by concern JE and Engr-in-Charge.
Taking down unserviceable panel of any size and any type and removing from site.
S&F in replacement of TPN DB 04 way double door conforming to IP43 &IK 09 protection complete with din rail, Neutral and Earthing bar after taking out the old unsv DBs, connection complete and making good the disturbed surfaces.
S&F in replacement of isolator, 4 pole, 63 Amp, 415 Volt.
S&F in replacement of MCB SPN 40 to 63 Amp, 10 KA, with over load and short circuit protection complete all as directed
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 Core incl taking out old unsv cable complete all as sepcified and as directed at site by Engr-in-Charge
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 3.5Core on wall with clamp incl taking out old unsv cable specified and directed at site by Engineer-in-Charge.
Material and labour submain wiring complete with 2 x 10 sqmm (nominal area) FR, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 10 sqmm as earth wire in existing conduit incl taking out old unsv cable complete all as specified and as directed
Excavation in trenches in loose/soft soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out including forming bottom surface for laying LT cable as specified and directed at site by Engineer-in-Charge.
M&L for sand cushioning to under ground cable provided with layers of sand(8 cms deep before laying the cable and 15 cms deep after laying) complete allas specified and directed at site by Engineer-in-Charge.
Removing exccavated soil not exceeding 50 mtr and depositing wheredirected at a level not exceeding 1.5 mtr above the starting point complete as specified and directed by the Engr-in-charge.
Returning filling in soil including spreading, levelling, watering and well rammingin layers not exceeding 25 cm complete as specified and directed by the Engr-in-charge.
Supply and laying burnt bricks class - B for protection of cable complete all asspecified and directed at site.
S&F of Static Energy Meter single phase electronic type with LCD display of capacity 10-60Amp including connection with seal and sealing wire taking out the old u/s and depositing to MES store yard. complete all as specified and as directed
Material and labour for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25 mtrs below ground level with top edge of plate not less than 1.5 mtr deep below normal ground level connected to galvinised earth wire 4 mm by means of nuts, bolts and check nut to earth plate and to main board or DB including necessary PCC 1:2:4 type B-1 pit, cover frame , GI pipe 15 mm dia light grade for protection and GI pipe 20 mm dia medium grade for watering with funnel, wire mesh, salt and charcoal dust all over the plate all as specified and as directed.
M/s Sohanil Construction
aggarwal engineers contractors
Surjit and Sons
R. S. Associates
Shiv Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .