| 1 | L1₹41.0 LAccepted-AOC CHENNAI | L1 | Accepted-AOC Admitted | |
| 2 | L2₹41.5 L+₹54,559 (1.33%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance Being Not Lowest Tenderer | |
| 3 | L3₹44.9 L+₹3.9 L (9.53%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L3 | Rejected-Finance Being Not Lowest Tenderer | |
| 4 | L4₹45.9 L+₹4.9 L (12.1%)Rejected-Finance 20 1 CHANDRA NIVAS APPLEBY ROAD WELLINGTON COONOOR NILGIRIS 643 232 | COONOOR | NILGIRIS | TAMIL NADU | 643232 | L4 | Rejected-Finance Being Not Lowest Tenderer |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
25 May 2023, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
SPECIAL REPAIRS TO BUILDING No XXIV G AND ROOF OF BUILDING No IV BARRACK SQUARE BLDG KR COY OF MRC WELLINGTON UNDER GE WELLINGTON
2023_MES_591685_1
8790/E8
Open Tender
Civil Works
Item Rate
180 days
Wellington
As per Tender Docuemnts
4 documents required · 4 mandatory
₹500
GE Wellington
₹93,000
Yes
14 Jun 2023
27 Apr 2023
1 Jun 2023
28 Apr 2023
25 May 2023
11 May 2023
Amount
Dismantling of asbestos cement corrugated, semicorrugated sheeting, any gauge and thickness in roof coverings including Nainital or similar pattern roof covering complete all as specified and as directed.
Dismantling of timber scantling 40 sqcm and over in sections in any position as in unframed works all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet as in ridge of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering and on chajjas etc fixed with self tapping screws all as specified and directed.
Preparation of old painted wooden surfaces and wood based materials of any description not other wise over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Preparation of old painted steel surfaces and steel based materials of any description not other wise over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets and frame work all as specified and directed.
Preforated Gypsum Board 12mm thick fixed with corrosion resistant self taping zinc plated dry wall screws with counter sunk cross head on snap grid in ceilings as per manufacturers instructions including anodised aluminium snap grif of size 605mm x 605mm using standard tea and angle sections such as Wall Angle of size 38 x 25 x 2.4mm weighing 0.36 KG/RM, Main / Cross tees of size 36.5 x 25 X 1.4mm weighing 0.24 KG/RM for false ceiling including cutting, drilling, jointing etc. complete including provision of 4mm dia GI wire suspenders fixed with adjustable connectors at interval of not more than 600mm centre to centre and applying two or more coats of cement based wall care putty of make JK/ Birla / Jenson & Nicholson / Alltek on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of acrylic emulsion paint over one coat of primer complete all as specified and directed.
Demolition of Brickwork, stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Pre-cast cement concrete block masnory with solid block using type C1, 1:3:6 using 20mm graded stone aggregate exceeding 10cm in width and setting in mortar 1:6 complete all as specified and directed
Rendering 15mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces, finished even and smooth without using extra cement all as specified and directed.
Plastering 15mm thick in two layers, 10mm thick in cement mortar 1:6 as dubbing coat 5mm thick in cement mortar 1:4 mixed with WPC on stone wall/ PCC Block / Brick work finished even and smooth without using extra cement etc complete all as specified and directed. Note: WPC will be measured and paid seprately.
Supply only liquid water proofing compound all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of Exterior Emulsion Paint ( Anti Fungal) white or tinted over a coat of primer over and including one coat in two layers of external wall care putty 2-3 mm thick in two layers as approved by GE complete all as specified and as directed.
Preparation of newly plastered wall surfaces and applying two coats of Oil Bound Distemper over one coat of primer over and including a coat of putty on wall complete and all as specified and directed.
Dismantling, floor hearth or wall tiling including cement mortar bedding complete all as specified and as directed.
Heavy Duty Non-Skid Ceramic tiles 15mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement slurry to match over and including15mm thick screed in cement mortar 1:4 complete all as specified and directed.
Heavy Duty Non-Skid Ceramic tiles 15mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, as in skirting/, dadoo etc. set and jointed in neat cement slurry and pointed in white or coloured cement slurry to match over and including 10mm cement plaster as backing coat in cement mortar 1:4 complete all as specified and directed.
Coloured Glazed ceramic tiles in vertical surfaces 450x350x7mm/ 300x600x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick plaster in cement mortar 1:4 on fair face of brick or concrete surface
Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and as directed.
Vitreous china wash down water closet pan (pedestal pattern) white with P or S trap incl flushing pipe , seat and PVC seat cover (white) closed pattern with flat bottom & cover brass chromium plated hinging device, incl connection to drain and to flushing pipe, antisyhonage pipe etc and including fixed in repairs complete all as specified and directed.
PVC low level flushing cistern 10 litres capacity, valveless, syphonic action type, white, with inlet ball valve, float and handle including connecting to bracket etc fixed in repairs complete all as specified and directed.
Vitreous china wash basin, white, flat back, size 550mm x 400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, with and including brass chromium plated perforated waste coupling / fittings 32mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, PVC waste pipe of 32mm bore and of suitable length, 15mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and PVC connection 15mm size with PTMT nuts of length 450mm and fixed in repairs complete all as specified and directed.
Taking down PVC/ CI pipe jointed in cement mortar, taking out wall and eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc. (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed
PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors all as specified and as directed.
PVC (SWR) bend of any radius 110 mm dia complete all as specified and as directed.
Taking down steel tubing and connections including cleaning for refixing or removal from site for 15mm bore pipe all as specified and directed.
Taking down steel tubing and connections including cleaning for refixing or removal from site for 20mm bore pipe all as specified and directed.
Supply, laying and testing steel water tubing medium grade galvanized with all GI fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor including cutting and chasing with all fitttings complete all as specified of size 15 mm bore.
Supply, laying and testing steel water tubing medium grade galvanized with all GI fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor including cutting and chasing with all fitttings complete all as specified of size 20 mm bore.
Stop valves, fancy type, chromium plated with long shank and cup concealed type, chromium plated 15mm dia cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair all as specified and directed
Pillar taps, 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed in repairs all as specified and directed.
Long body bib tap fancy type Chormium plated fixed to 15mm dia in repairs,complete all as specified and as directed. Make :- Cat No. CON-107KN of Jaquar or equivalent
Taking down PVC / wooden chowkat or frame with shutter (without taking off shutters from the frames) area exceeding 1.5 Sq mtr but not exceeding 4 Sq mtr all as specified and directed.
2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue, pinned at joint all as specified and as directed.
Anodised aluminium frame powder coated for doors, windows ventilators, with one or more rebates including joining cleat for fixing etc., complete all as specified and directed.
PVC (SWR) floor/ Nahani trap 75mm outer dia, plain with grating including jointing to waste pipe with solvent cement all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed.
Taking down complete of existing water proofing treatment of any description over roof slabs / parapets etc complete all as specified and directed.
Demolition of existing old padding concrete of any thickness of existing water proofing treatment over the RCC slab other than beams, chajjas, staircase etcby chipping of with proper tools viz chiesel and with applying resonable force so as to avoid any damage to esisting RCC roof slab complete all as specified and directed.
Providing Plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate average thickness 40mm as in levelling / padding course on roof slab, projections on similar surfaces existing with slope making the surface even and smooth without using extra cement all as specified and directed.
Rendering 10mm thick fair faces of brick work or concrete surface in cement mortar 1:3 laid over the RCC roof slab, parapet wall when the concrete is green at any height and making the surface fair and even without using extra cement mixed with WPC as per manufacturer's instructions all as specified and directed. Note: Water proofing compound will be measured and paid separately.
APP modified prefabricated polymeric water proofing membrane mineral finish 4mm thick and weighing not less than 4.5 kg/sqm reinforced with non-woven polyester matt black finished weighing not less than 100 gm/sqm having softning point less than 140 degree celcius longitudinal tensile strength not less than 300N/sqcm, side lap 10cm with torch application of membrane over compatible primer at 0.40 Ltr/sqm and aluminium paint at 0.10 kg/sqm finished on top complete all as specified and directed. Note: The work shall be executed by authorised applicators only.
Plain cement concrete Type B1 1:2:4 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Plain cement concrete 1:2:4 type B2 (using 40mm graded stone aggregate) 100mm thick as in flooring, tank stagging complete fair finished even and smooth without using extra cement all as specified and directed.
Dismantling of asbestos cement corrugated, semicorrugated sheeting, any gauge and thickness in roof coverings including Nainital or similar pattern roof covering complete all as specified and as directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spaced exceeding 15cm all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Second class hardwood as in scantling clean swan, fixed to timber frame work complete all as specified and directed
Galvanised, corrugated mild steel sheeting 0.63mm with two corrugation side lap fixed with coach screw and washers, in roofs walls etc. with grade of zinc coating 275 all as specified and directed.
All as per item No 51 hereinbefore but except sheets all as specified and directed.
Second class HW, clean sawn, battens, exceeding 15 Sqcm and not exceeding 25 Sqcm in cross section, spaced at 30 cm centres all as specified and directed.
Second class HW, clean sawn, battens, exceeding 5 Sqcm and not exceeding 15 Sqcm in cross section, spaced at 30 cm centres all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) all as specified and directed.
15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement all as specified and as directed.
Preparing surfaces, plastered or unplastered on new wall surface and applying two coats of white wash complete all as specified and directed.
Preparation of wooden surfaces and applying two coats creosete oil over wooden surfaces all as specified and directed.
Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed.
Dismantling of Wrought Iron or Mild steel work of any description not otherwise provided for complete all as specified and directed.
Mild steel works in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle) including distance pieces, cleats etc.of grade Fe-410-W (Gde-E-250) quality-A all as specified and directed.
Mild steel Framed work such as grill, grating etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars, barred iron door, ladders, framed balusters and simialr work conforming to Fe290 Gde E-165 all as specified and directed.
Preparation of new or untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
Chipping out of cement plaster of ceiling /wall surfaces of RB slab (Brick slab) including racking out joints upto depth of 75mm and filling by mortar Nitobond SBR and plastering surface 5mm thick by Reneroc SP 40 of make FOSROC cementitious reapir mortar complete all as specified and directed. Note: WOrk shall be carried out as per Manufacturer's Instructions and by manufacturer's applicators only.
Rendering 5mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling finished even and smooth without using extra cement complete as specified and directed. Note: 1. Work has to be carried out on ceiling in between rafter areas having width of not exceeding 30cm of brick slab. 2. Necessary measures to be considered to avoid damage of brick slab by the contractor.
Preparing surfaces, plastered or unplastered on new ceiling surface and applying three coats of white wash complete all as specified and directed.
Ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in repairs of size 20mm dia (Minimum weight 25mm-455gms) complete all as specified and directed.
Gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of size 20mm dia all as specified and directed.
Dismantling PVC water tank exceeding 500 ltrs and not exceeding 1000 Ltr capacity from existing position all as specified and as directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layers of capacity 1000 Ltr hoisted and fixed in position with proper inlet and outlet connections all as specified and directed.
Demolition and breaking up drain pipe of any description of any size complete all as specified and as directed.
PVC (SWR) 110mm dia pipe single socketed in any length, with rubber ring joint fixed to walls with clamps complete all as specified and directed.
Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell etc, and making good disturbed surfaces with smooth finish matching with the existing surface of walls, floors, etc. and with existing colour all as specified and directed.
Material and labour for Point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed stranded copper conductor single core cable 1100 volts grade in and including PVC conduit medium grade in concealed complete with conduit fittings/ accessories including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed. Note: 1. Sunken box/ Cover plate for modular plate for modular switches, sockets etc will be measured and paid separately under relevant items and blank plate required if any will be deemed included in the item rate. 2. Cutting chases in stone masonry wall will be measured and paid separately.
All as per Item No 74 hereinbefore but One 3 pin 5 Amps socket out let on independent Board all as specified and directed.
All as per Item No 74 hereinbefore but point wiring complete with 2.5 sqmm FRLS cable for 3 pin 15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed.
All as per Item No 74 hereinbefore but point wiring complete with 4 sqmm for 3 pin 15 A socket outlet on independent board including 4 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed.
Ceiling rose, 3 terminals PVC / polycarbonate, isolated body all as specified and directed.
Modular switch one way 6A 230V AC 50 HZ SP one module all as specified and directed.
Modular switch one way 16A 230V AC 50 HZ SP one module all as specified and directed.
Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified and directed.
Taking down unserviceable DBs with MCBs and Supply and fix MCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed. Make: ABB/ Legrand/ L&T.
240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP in the MCB DB complete with connection testing and commissioning all as specified and directed.
All as per Item No 83 hereinbefore but 'C' Curve 32 Amps SPN all as specified and directed.
Taking down old unsv FTL fittings, Supply and fix 24W LED batten light Lum output 2000 CCT 6500K size 115x2.5x3.5 cm comprises of thermally conductive material pre-wired with high efficiency electronic driver, high translucent serrated milky white diffuser gets glare free, smooth light distribution lamp colour white all as specified and directed. Make. Panasonic Product Code-PBTM06247 or equivalent in Philips / Bajaj.
Taking down Submain wiring with aluminium conductor along with PVC Conduit and Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed. Note: 3 Runs of cable and one run of conduit shall be measured as one RM
Modular Metal Flush Box 1/2 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular Metal Flush Box 3 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular Metal Flush Box 4 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular Metal Flush Box 6 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate With Frame White cover plate with frame, 1 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate With Frame White cover plate with frame, 2 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate With Frame White cover plate with frame, 3 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate With Frame White cover plate with frame, 4 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate With Frame White cover plate with frame, 6 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Taking down unserviceable building security light and Material and labour for LED Security Light fitting of 15 Watt, 5700K comprising of eposy powder coated housing enclosed with glass cover in frame with protection IP 65 complete with all accessories and lamp colour white all as specified and directed. Make: Panasonic Cat Part No PSTM27158 / Philips / Bajaj.
GI Pipe light Grade 40 mm bore bracket of suitable size bent to shape of not less than 1.2m long with clamp made of GI flat Iron of size 32 x 6mm for street light fittings, duly painted with one coat of red oxide primer and two coats of aluminium based paint, fixed on poles with bolts, nuts and washers complete all as specified and directed.
Cutting chases in stone masonry wall/concrete floor/roof for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exceeding 10cm girth all as specified and directed
Air termination, single pointed aluminium rod 12mm dia and 300mm long in repairs all as specified and directed.
GI pipe of size 40mm dia and 1 meter long for fixing air termination rod along with necessary fixing accessories complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw in repairs all as specified and directed
Supply and fix aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
Galvanised iron strip 32 x 6mm buried in ground for inter linking all earths all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60Cmx60Cmx6mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised iron earth strip 25mm x 4mm by means of bolts, nuts, hook nuts and washers of galvanised steel all as shown in electrical plate no 3 of SSR Part I connected to earthing testing point including earth and excavation work, PCC as directed, etc all as specified or indicated including testing on completion.
GUNASEKARAN AND CO
Sree Constructions
P K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .