computer servers Computer Servers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Specification Form Factor Rack Rack Size (RU) 1 * Processor Make Intel Intel Max. Number of sockets available on chipset 2 1-16 Max. Number of sockets populated with processor 1 1-16 Number of core per Processor 8 * Processor Configuration Intel Xeon Bronze 3106 (1.70GHz/8-core/11MB 85W) Intel Xeon Bronze 3106 (1.70GHz/8-core/11MB 85W) Chipset compatible with CPU C621 * Availability of Co- Processor No * If Yes Co-Processor Configuration NA * 1/4 PCI Slots (Express Gen 3.0) 3 * Type of RAM DDR4 * RAM Size (GB) 16 16 RAM upgradable upto (GB) 1500 32-24000 DIMM Slots (No.) 16 * Type of Hard Disk Drive SAS SAS
NL SAS
SSD
SATA Hard disk drive Capacity (GB) 1200 300-12000 Hard disk drive Speed (RPM) 10K * RAID Controller Cache (MB) 2048 * RAID Type 5 * RAID Controller Ports @12 Gbps 8 * Video Controller (support VGA or above resolution) Yes * Keyboard No * Mouse No * Bays (min. 2 internal or more hot plug) 8 * USB Ports (version 2.0/3.0) 3 * Certifications Compliance support by Windows
Red Hat or Novell or Oracle Cluster S/W Yes * DVD ROM (or better) 8x or better * Network Card Supported 100G * FC HBA Dual port card NA * FC HBA Dual port card Speed NA * Power Management - * Redundant Power Supply No * Redundant Fan No * Total No of Ports 4 x 1 Gbps * Declare SPEC We will provide later to * 2/4 int_rate_base 2006 ; specfp_rate_2006 for 1
2
4
8 prcessor as applicable buyer Server scalability to be achieved within the box without adding nodes NA * RoHS Compliance Yes * BIS Registration number & its Validity - * Max. power consumption of the system (Watt) 500 * Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
the server shall be functional No * Name address of Lab - * Test Report No. date - * Power Supply 230 V +/-10%
50 Hz * On Site OEM Warranty (years) 3 1
3
5 (or higher) * Bold specifications are the golden parameters. 3/4 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jayaprakash G 600023
Office of the Deputy Chief Materials Manager Carriage Stores Depot Perambur 1 15