Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.2 L+₹1.9 L (26.2%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹12.5 L+₹5.2 L (71.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹12.9 L+₹5.6 L (77.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹14.6 L+₹7.3 L (100.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
3 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj. Sujith Mohan, GE
Garrison Engineer 864 Enggr Wks Sec, PIN-913864,C/o 56 APO
Repair /mant. of AC,refrigerator,deep freezer,voltage stabilizer and E/M misc works at BB cantt Srinagar
2023_MES_599335_2
864/WS-40/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
B B Cantt.
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹30,000
Yes
13 Nov 2023
11 Oct 2023
6 Nov 2023
11 Oct 2023
3 Nov 2023
21 Oct 2023
Amount
Taking down the Split AC of Capacity 1.5/2 TR by disconnecting of refrigerant and electrtic connections of the inner and outer unit and removing the AC unit for cleaning /servicing with pressure water to remove oil, grease and dust without spoiling control wiring or damaging of electric motors,apply one coat of clean solution with wire mesh brush /nylon brush to the condensing coils of out door and inner unit including oiling and greasing to all moving parts with replacement of the defective parts, gas charging & testing after reinstalling of the split AC compete all as specified and directed . (Note :- Spares and Gas charging shall be measured and paid separately under relevant items as supply only).
Disconnecting of electric connection of the window type AC from its stabilizer or its electric board and taking out the unit carefully for carrying out the cleaning /servicing unit with pressure water to remove all dust and sand particles then apply one coat of cleaning solution and clean the unit with wire mesh brush /nylon brush, applying oil and grease to all moving parts including condensing motor and replacing the defective spare part including testing after refixing of AC unit at its original position and connecting it with the electric system complete all as specified and as directed. Note: Spare parts shall be measured and paid seperately under relevant items as supply only.
Supply only in replacement sealed reciprocating compressor unit for 1.5 TR window type AC complete, all as specified and as directed.
Supply only in replacement sealed reciprocating compressor unit for 1.5 TR Split type AC complete, all as specified and as directed.
Description all as per srl item No 4 above but rotary type sealed compressor suitable for 2ton AC.
Supply only kit wiring for window type AC cpacity 1.5 TR complete, all as specified and as directed.
Supply only in replacement drain pipe PVC of size 15 mm 3 Mtr long complete, all as specified and as directed.
Supply only in replacement Printed Circuit Board for split type AC operating at hot &cold mode of capacity 1.5 /2Ton complete, all as specified and as directed.
Supply only in replacement of Printed Circuit Board for window type AC operating at hot &cold mode of capacity1.5 Ton .complete, all as specified and as directed.
Supply only of front cabinet grille for 1.5/2 TR capacity window type AC complete, all as specified and as directed.
Supply only in replacement evaporator unit of capacity 1.5 TR comprising of copper tubes and finns including flare nuts and proper pressure testing of the unit for leakage after fixing complete all as directed .
Supply only in replacement, condenser unit of capacity 1.5 TR comprising of copper tubes and finns including flare and dead nuts and proper pressure testing of the unit for leakage after fixing complete all as directed .
Supply only in replacement, evaporator unit of capacity 2 TR comprising of copper tubes and finns including flare nuts and proper pressure testing of the unit for leakage after fixing complete all as directed .
Supply only in replacement, condenser unit of capacity 2 TR comprising of copper tubes and finns including flare and dead nuts and proper pressure testing of the unit for leakage after fixing complete all as directed .
Supply only in replacement, polyvinyle chloride front grille with cabinet cover of inner unit of 1.5/2 TR split AC complete, all as specified and as directed.
Supply only in replacement, starting capacitors 80-100MFD 6 pin complete all as specified and as directed
Supply only running capacitors 80-100 MFD complete, all as specified and as directed.
Supply only in replacement, condenser Motor 1/3 HP with fan blade and bracket suitable for split type AC 1.5TR complete, all as specified and as directed. .
Supply only in replacement, Inner unit (evaporator) asynchronous Motor 25 W, 4 pole 220-240 Volt with SS single shaft suitable for split type AC 1.5/2 TR .
Supply only in replacement, control display panel (single line/double line) of split AC of capacity 1.5/2 TR complete, all as specified and as directed.
Supply only in replacement, knob suitable for window type AC of Capacity 1.5 TR complete, all as specified and as directed.
Supply only in replacement, starting relay for Window/split type AC 1.5 to 2TR complete, all as specified and as directed.
Supply and fixing in replacement, split AC outdoor unit 1.5TR consisting of compressor, condenser coil, blower motor with fan etc. complete, all as specified and as directed.
Supply only of refrigerant R-22/R-410 after nitrogen flushing and pressure testing of close ciruit (compressor and refrigerant lines) of Split /window type of any capacity complete all as specified and directed .
Supply only butane in catridge for brazing of copper tube and tube joint of Split /window type of any capacity complete all as specified and directed .
Supply only teflon tape for AC,s of size 25mmx25mm complete, all as specified and as directed.
Supply only PVC insulation tape of AC,s of size 25mmx25mm, complete, all as specified and as directed.
Supply and fixing in repacement of MCB SPN 32 Amps 10 KA 'C" curve, complete, all as specified and as directed.
Supply only in replacement polyvinyle chloride air filter for split type A/C of any capacity 1.5/2 TR .
Supply only in replacement, polyvinyle chloride air filter for window type A/C of capacity 1.5/2 TR complete, all as specified and as directed. .
Supply only in replacement, thermistor for Split A/C complete, all as specified and as directed. .
Supply only in replacement, thermistor for 1.5 TR window type A/C complete, all as specified and as directed. .
Supply only in replacement, swing motor with wiring leads for inner unit of 1.5/2 TR Split AC complete, all as specified and as directed. .
Supply only in replacement, axial PVC blower with end bushes for inner unit of 1.5/2 TR Split AC complete, all as specified and as directed. .
Supply only in replacement , PVC louver flap complete with links for inner unit of 1.5/2 TR Split AC complete, all as specified and as directed. .
Supply only reverse valve by soldering brazzing with reverse coil for Hot & Cold AC of capacity 1.5 TR including extension of refrigerant pipes and testing complete all as directed.
All as per item ser No 37 here in above but suitable for 2Ton AC
Dismantling of Refrigerator /Deep freezer of any capacity for carrying out repair/replacement of following worn out parts and reassembling , testing and commisioning of the same after repairs ,comlete all as directed. (Note: Spares and Gas charging to be measured and paid seprately under respective items as supply only)
Supply only compressor 'A' type suitable for refrigerators of capacity 165-180 Ltrs.
Supply only compressor 'B' type suitable for refrigerators of capacity 190-240Ltrs .
Supply only compressor 'C' type suitable for refrigerators of capacity 240-410Ltrs .
Supply only compressor 411 KCN suitable fordeep freezer of capacity 260-600 Ltrs .
Supply only Freezer compartment of Refrigerators of capacity 165-240Ltrs
Supply only condensing coil of Refrigerators of capacity 165-240Ltrs
Supply only Freezer compartment of Refrigerators of capacity 240-410Ltrs
Supply only condensing coil of Refrigerators of capacity 240 - 410 Ltrs
Supply only refrigerant R-134(a) including nitrogen flushing , vaccumization and pressure testing complete all as directed.
M&L for copper tubing size 3/8" for Refrigerent gas line with nitrile insulation including making connection with flare nut of same size after cutting every 5m complete all as directed.
M&L for copper tubing size 1/4" for refrigerent liquid line with nitrile insulation including making connection with flare nut of same size after cutting every 5m complete all as directed.
M & L for capillary tube 1/32 "of copper including making connection complete all as directed.
M&L for isolating the voltage stabilizer of capacity 4/5KVA single phase by disconnecting all electrical connections and dismantling the same for carrying out cleaning, one coat spray painting , repairing /replacement of following worn out parts and reassembling, testing complete in all respect Note :- Any parts/spares requires shall be measured and paid separately under relevant item.
Rewinding of main transformer of 5/4 KVA with same gauge super enameled copper winding wire complete with insulating materials and varnishing heating for dry up including taking out of burnt/unserviceable winding all as specified and directed .
Supply only printed circuit board for 5/4 KVA voltage stablizer
Supply only relays for 5/4 KVA voltage stablizer
Supply only of voltmeter 0-300 volts
Supply only switch /socket terminal of rating 5/15 Amp including control wiring
Supply and fixing in replacement Quartz tube of Heat piller 40 cm complete all as specified and directed .
Supply and fixing in replacement Heat elements coiled 750 Watt of heat piller complete all as specified and directed
Supply and fixing in replacement Heat resistance Connector strip of copper double complete with lugs complete all as specified and directed
Supply and fixing in replacement Switch block eiose flash set of three 15 Amp complete all as specified
Supply and fixing in replacement Propeller fan with blade 100 mm complete all specified and directed
Supply and fixing in replacement Heat Resistance connection of copper complete all as specified and directed
Supply and fixing in replacement Osillation motor AC 230 V 90 degree cut complete with base all as specified and directed
M & L for PVC insulated 4 sqmm flexible cord 3 core with stranded copper conductor, all as specified and directed.
M & L for PVC insulated 4 sqmm two core multistranded copper conductor all as specified and directed.
M & L for PVC insulated 2.5 sqmm single core multistranded copper conductor all as specified and directed.
M & L for PVC insulated 6 sqmm single core multistranded copper conductor all as specified and directed.
M & L for PVC insulated 4 sqmm single core multistranded copper conductor all as specified and directed.
Supply only nitrile insulation of density 13mm thick suitable for refrigerant tubing of dia 1/2".
Supply only nitrile insulation of density 13mm thick suitable for refrigerant tubing of dia 1/4".
Supply only single phase portable AC Washing Pressure pump C120,1800Watt.
Supply only brazing Rod for welding.
Supply only AC Stand for outdoor unit of wall brackets with fasteners is suitable for all brands AC out door units powder coated meatal wall mounted carring capacity 1.5/2Ton AC
Supply and fixing in replacement starting capacitors 36-200MFD 6 pin / 4 pin complete all as specified and as directed
S&F in replacement, indoor unit blower motor with blower 1.5 Tr/2 tr air conditioner any type & any make as per sample including inverter model
S&F in replacement, outdoor unit fan motor with fan1.5 Tr/2 tr airconditioner any type & any make as per sample including inverter model
Supply Only remote control for 1.5 /2.0 tr inverter/ Non inverter airconditioner of any type & make as per sample
M/S FAISAL TRADING CO.
ORISON ENTERPRISES
M/S M.A.S ELECTRICALS
M/S GHULAM MOHD AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .