| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹45.9 L+₹4.5 L (11.0%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹46.7 L+₹5.3 L (12.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹48.8 L+₹7.5 L (18.1%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
27 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) LUCKNOW
GE (WEST) LUCKNOW PIN 226002 C/O 56 APO
REPAIR/ MAINT AND RENEWAL OF MISC E/M ITEMS IN ZONE A B C UNDER GE (WEST) LUCKNOW
2024_MES_681919_1
GE/W/LKO/82 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LUCKNOW
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (WEST) LUCKNOW
₹1 L
Yes
14 Dec 2024
30 Oct 2024
29 Nov 2024
30 Oct 2024
27 Nov 2024
13 Nov 2024
30 Oct 2024 - 6 Nov 2024
Amount
Taking down old U/S Bldg security/street lights/Gate lights/Bollard light/flood lights of any type any size retreived from existing site complete all as specified and as directed.
S&F in repair LED Building security light 20/25 Watt with high power LED source (>100 lumen/watt) PDC housing, IP66 and IK 07 with 4 KV inbuilt surge protection ,minimum 50000 burning hours hv cutoff@325/440 volt protection for 8 hours including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and as directed Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and fix LED in repair gate light of 40/45W LED Postop luminaire with aluminium pressure die-cast mounting spigot & polyester powder coating in addition to a specific weathering resistance treatment, color RAL7011. Non-yellowing transparent Polycarbonate UV-protected round symmetrical diffuser with circular radial pattern for glare-free and even light distribution. High Efficiency long life LED module with efficacy of >100Lm/W, IK10, CCT 4000K, and CRI >70. Powered by built-in electronic driver with THD <10%, 4kV inbuilt surge protection, high cut-off at 325V & auto-restart, including 8hrs. protection from 440V (P2P). Incl GI Pipe 40mm dia 0.45mtr long fixed in gate pole with PCC 1:2:4 of 0.20 mtr height and size of existing gate pole. Fixture lumen efficacy >4500 Lm, IP66 (no glue), IK05, PF>0.95, Operating voltage range: 140- 277V, complete all as specified and as directed
Supply and fixing in repair LED building security light of 25W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5.minimum 50000 burning hours Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and as directed
Supply and fixing in repair LED building security light of 35/36W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5.minimum 50000 burning hours Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and as directed
Supply and fixing in repair LED building security light of 40W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and as directed
Supply of 45W pressure Die cast aluminium housing building secuirity light in repair with system lumen of 6300lm & system efficacy of 140Im/W, IP66, IK10, Single piece die cast including spigot, dia 48-76mm, LED Lifetime (L70B50) 75K Hrs with integrated optical cover. Streetlight should have standalone lighting control system with AUTO on/off based on Dusk/Dawn timings, preset time setting with monthly variation(Jan to Dec.), inbuilt Real time clock for switching, includes dimming profile for energy savings, drift not exceeding max 2mins per year, clock retention upto five years, auto switching off secondary power for module, dimmable driver based on PWM control, dim to off with High/Low Voltage cut off with 440V protection for 8 hrs for complete luminaire including driver and Astro module, EMI/EMC complaint as per EN55015,IEC61547.surge protection as per IEC 61000-4-5,driver meeting IEC61347,complete luminaire meeting IEC60598-2-3-2002, Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval complete all as specified and as directed
S & F in repairs integrated LED type Bollard , 10/12 W LED as light source, IP 65,IK 07 minimum hieght 750mm AL PIPE HOUSING , PF0.95 AND SBD 4KV energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution incl LED driver with base plate and pcc and earth work for grouting the light complete and incl neceesary electrical connection complete all as specified and directed.
S & F in replacement street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm with nuts bolts & washers for fixing on wall complete necessary fixing arrangements on pole incl taking out old U/S bracket as directed.
Supply and fix in repair of LED 2x2 architectural recessed/ surface luminaire with CRCA housing and Molded PC diffuser with an unique angular optics for making the illumination easy on eyes for light comfort in office areas with UGR<=19. The luminaire should have a color consistency SDCM< 5, CRI > 80 and choice of CCT: 5700K. Luminaire shall be designed to emit at least 4200 lumens and an efficacy of atleast 120Lm/W and maximum system wattage of 36Watt. Avg life class L70B50@50k burning hours, designed for ambient temp 45 deg C. The metallic electronic driver shall have a power factor >0.95, THD <10%, 4KV internal surge protection and the Ripple factor should be <5% to minimise the Flicker and Stroboscopic effect. Fixture should have an operating voltage range of 140-270VAC. It should have over voltage protection @320V Cut-off with auto restart features. including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and as directed
Supply and fix in replacement LED 35-40 watt light pureline slim suspended 50mm with suspended (hanging type) accessories CRCA WHITE POWDER COATED ,50000 burning hours efficacy >120L/W, IP20 and Ik02 linear lighting luminaries with superior white powder coated finish, multiply option options of lights distrubution run length and luman packages for diffrent application to choose white colour higher energy saving decorative ultra slim square profile LED lighting fixture enviromental friendly, energy efficient complete all as specified and as directed
Supply of Smart Glow 2x2PANEL SENSOR LIGHT recessed/surface type is an intelligent office lighting system in repair with an inbuilt sensor thus avoids unwanted hassle of creating space for sensors. The inbuilt sensor helps save additional 40%* energy as compared to other LED panels. The luminaire also provide 360Deg coverage around 8 ft area, High on aesthetics, SmartGlow delivers superior performance, is easy to install and has a long life of 50,000 hours (L70B50). It also has very good payback period of less than 1.5 years, System wattage: 37W with system lumen of 3700lm, system efficacy>100lm/watt, Housing made with CRCA material, high transmittance PC diffuser to provide uniform light intensity distribution, IP20, THD<10%, available CCT: 4000K/5700K/6500K, CRI>80, PF>0.90, Operating voltage: 220-240Vac at rated frequency of 50Hz. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and as directed
Supply & fix in replacement LED Ceiling /surface mounted down lighter warm white / white colour,12 to18 watt round/ squre profile,including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and as directed
Supply only highly durable built -in LI-ION LED bulb invereter rechargable type having backup time of 3 to 4 hours 12/14 Watts suitable for B22 white in colour with one year warranty complete all as specified and as directed
Supply only highly durable built -in LI-ION LED bulb inverter rechargable type having backup time of 3 to 4 hours 18 Watts suitable for B22 white in colour with one year warranty complete all as specified and as directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell, bell push, light fitting etc for taking credit and making good disturbed surfaces of walls, floors,etc complete all as specified and as directed
Taking down OLD U/S Switch/socket/Ceiling rose/calling bell/bell push/lamp holder/Regulator any type and size complete all as specified and directed.
M&L for point wiring complete for one light point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn into and including suitable size surface conduit/casing caping, including PVC one way gang switch boxesuitable for 5amp swicth complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.
All as per Item No 19 above but for one 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed
All as per Item No 19 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed
All as per Item No 19 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm complete all as specified and as directed
S & F switch piano flush button single pole one way 5 Amp 240 volt complete all as directed complete all as specified and as directed
S & F switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and as directed.
S&F socket outlet flush type multipurpose 2 in1, 3 pin 5 and16 Amp, 230 volts complete all as specified and as directed
S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6Amp, 230 volts complete all as specified and as directed
S&F in replacement angle/batten type holder insulated body with back plate suitable for led bulb/emergency bulb complete all as specified and as directed
Supply and fix in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and as directed
Supply and fix in replacement LED tube light fittings 1200 mm, 20 W, 110 L/W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminium housing without powder coating enviromental friendly, energy efficient complete all as specified and as directed
M &L in replacement for batten suitable for replacement type LED TUBE LIGHT 4' feet long incl prewired complete all as specified and as directed
Supply and fixing in repair Material glass led tube ,voltage range 220-240v-50hz ,cct 6500k,lumen ,wattage 20/22W surge 2.5kv ,CRI 70 POWER FACTOR >_0.9 ,BURING HOURS 25K HOURS 110 L/W ,6000 K with high efficency, with neccessary electrical connection incl disconnection old elecronic ballast if any complete all as specified and as directed
Supply and fix in replacement LED tube light fittings 600 mm,10/12W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminium housing without powder coating enviromental friendly, energy efficient complete all as specified and as directed
Supply & fix in replacement LED wall/surface mounted down lighter round/sqaure, 6 to 12 W including electrical connection with copper flexible wire & all necessary fixing accessories complete all as specified and as directed
Supply and fixing in replacement microwave sensor based integrated LED tube light fittings 1200 mm with factory set dimming profiles of 50% and 100% light dimms to these levels in case occupacy is not detected , 18/20 W,110L/W 25000 BURNING HOURS higher energy saving decorative ultra slim square profile LED lighting fixture with extruded alumium housing without powder coating enviromental friendly, energy efficient complete all as specified and as directed
Supply and fixing in repair modular type AC box with socket plug top and MCBs with two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed
Supply in replacement only LED bulb 9/10 Watts suitable for B22 white in colour complete all as specified and as directed
S & F in replacement PVC casing n caping ISI marked of size 20mm complete all as specified and as directed
S & F in replacement PVC casing n caping ISI marked of size 25mm complete all as specified and as directed
S & F in replacement rigid non-metallic PVC conduit of size 20mm complete all as specified and as directed
S & F in replacement rigid non-metallic PVC conduit of size 25 mm complete all as specified and as directed
S & F in replacement Flexible conduit of size 20mm complete all as specified and as directed
S & F in replacement Flexible conduit of size 25 mm complete all as specified and as directed
S & F in replacement PVC gang box suitable for 6 Amp Socket and 6 amp switch complete all as specified and as directed
S & F in replacement PVC gang box suitable for 16 Amp Socket and 16 amp switch complete all as specified and as directed
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 6 sqmm aluminiuam conductor complete all as specified and as directed.
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 10 sqmm aluminiuam conductor complete all as specified and as directed.
S & F in replacement decorative ,wall mounted bed side LED light fittings 09 Watt , brushed nikel finish fixture with opal glass diffuser suitable with 9 watt LED bulb B 22 base energy saving complete all as specified and directed.
S&F the insulation tape 10 Mtr complete all as specified and directed
S&F the insulation tape 15 Mtr complete all as specified and directed
S&F the insulation tape 25 Mtr complete all as specified and directed
S&F in replacement of unserviceable wire of size 1.5 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 2.5 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 4.0 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 1.5 Sqmm three core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
Taking down recess mount light without disturbing false and disconnect electric connection & Supply and fix Driver of suitabe 2x2 ceiling light complete all as specified and directed
S&F in repair sheet metal enclosure for MCB DB double door type, single pole and neutral 4 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and as directed
S&F in repairs double door VTPN 4 way double door suitable for 4 pole MCCB 63-125A, 415 V as incoming & SP/TP MCB as outgoing 200 Amps rated Busbar, inter connection link, cable ties,earth bar IK09, True IP 43 (with PU Gasket) with test certificate etc incl necessary civil works and electrical connections with suitable lugs/spreader links complete all as specified and as directed. (Note: MCCB & MCB to be measured and paid seprately)
S&F in repair sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F in repair sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated,IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed
S&F in repair sheet metal enclosure for MCB DB double door type, triple pole and neutral 4 way 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate ,factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
M & L for replacement TPN MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 complete all as specified and as directed
M & L for replacement TPN MCB 100 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete conforming to IS 8828, IEC 60898 complete all as specified and as directed
M & L for replacement TPN MCB 63 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete conforming to IS 8828, IEC 60898 complete all as specified and as directed
M&L in replacement of SP MCB 6 TO 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 complete all as specified and as directed
M&L in replacement of MCB Single Pole & Neutral MCB 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 complete all as specified and as directed
M&L in replacement of MCB Single Pole & Neutral MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 complete all as specified and as directed
M&L in replacement of MCB Single Pole & Neutral MCB 63 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 complete all as specified and as directed
Supply and fixing in replacement of MCCB current rating 100 Amps with thermal magnetic release, 4 pole, 415 volts AC 16 KA Ics = 50% Icu as per IEC 60947-2 ruputuring capacity complete all as specified and as directed
Supply and fixing in replacement of MCCB current rating 125 Amps with thermal magnetic release, 3 pole, 415 volts AC 36 KA Ics = 50% Icu as per IEC 60947-2ruputuring capacity complete all as specified and as directed
Supply and fixing in replacement of MCCB current rating 125 Amps with thermal magnetic release, 4 pole, 415 volts AC 36 KA Ics = 50% Icu as per IEC 60947-2ruputuring capacity complete all as specified and as directed
Material and labour for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including existing complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and includingexisting complete with and complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour in repair for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Material and labour for replacement of unserviceable fan regulator electronic rotary step type 110 W (Switch in size 1 Module) suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed
Supply and fixing Twisted twin core flexible copper cable of size 23/0.0076 complete all as specified and as directed
S & F in replacement of switch piano flush button single pole one way 5/6 Amp 240 volt complete all as specified and as directed
S & F in replacement of switch piano flush button single pole one way 15/16 Amp 240 volt complete all as specified and as directed
S&F in replacement of socket outlet flush type multipurpose 2 in 1, 3 pin 5/6 and 15/16 Amp, 230 volts complete all as specified and as directed
S&F in replacement of unservicable socket outlet flush type multipurpose 2 in 1, 6pin 5 .Amp, 230 volts complete all as specified and as directed
S&F in replacement bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and as directed
S&F in replacement call bell AC single pole 240 volt ding dongType. complete all as specified and as directed
S&F in replacement angle/batten type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed
S&F in replacement modular switches 1 way 6A,1 module complete all as specified and as directed.
S&F in replacement modular switches 1 way 16A,1 module, complete all as specified and as directed.
S&F in replacement modular 6 A sockets-5 pin 2 module complete. complete all as specified and as directed.
S&F in replacement modular 6A/16A sockets-3/5 pin combine 2 module complete all as specified and as directed.
S&F in replacement Modular white cover plate with frame 8 module complete all as specified and as directed.
S&F in replacement Modular white cover plate with frame 6 module complete all as specified and as directed.
S&F in replacement Modular white cover plate with frame 4 module complete all as specified and as directed.
S&F in replacement Modular white cover plate with frame 3 module complete all as specified and as directed.
S&F in replacement Modular white cover plate with frame 2 module complete all as specified and as directed.
S&F in replacement modular bell push single pole one way 6/10 Amp, 240 volt,1 module, fuesh type complete all as specified and as directed
S&F in replacement of unservicable Switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, , 230 volts complete all as specified and as directed
Supply and fix in replacement modular type blanking plates, one moudle complete all as specified and directed.
Joy Dey Enterprises (BID ID -3170497)
M/S R J CONSTRUCTION CO (BID ID -3169569)
Unnati Engineers (BID ID -3175342)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .