Loading…
Loading…
Tender Value
₹20 L
EMD Value
₹15,000
Closing Date
23 Jun 2026, 5:30 pm
MR SE DURG 3 KUSUM DEWANGAN
CE,DURG
Water Proofing Treatment And Ordinary Maintenance in Residentaial & Non Residential Building Under Under Sub Division Bemetara (Zonal Agency)
192644
NIT NO. 118/Durg(Bemetara)/2026
RESTRICTED TENDER
WORKS
CE
Required Past Technical Experience: As Per NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
5 documents required · 5 mandatory
Public Works Department (PWD)
WORKS
MR SE DURG 3 KUSUM DEWANGAN
RESTRICTED TENDER
PERCENTAGE
A B C D
CE,DURG
DURG,CIRCLE
DIVISION BEMETARA
120
No
1
7137000
12012023
192644
23 Jun, 2026 5:30:38 PM IST
30 Jun, 2026 11:30:14 AM IST
8 Jun, 2026 7:30:24 PM IST
29052026
NIT NO. 118/Durg(Bemetara)/2026
Water Proofing Treatment And Ordinary Maintenance in Residentaial & Non Residential Building Under Under Sub Division Bemetara (Zonal Agency)
15000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
2000000.00
2
25 Jun, 2026 5:30:02 PM IST
2000000
AS PER NIT
AS PER NIT
As Per NIT
0.00 INR
08
14d 23h 43m
4910520230005 ,4910520230006 ,4910520230007
5 documents required · 5 mandatory
₹0
₹15,000
8 Jun 2026
8 Jun 2026
30 Jun 2026
8 Jun 2026
23 Jun 2026
8 Jun 2026
25 Jun 2026
NIT Schedule for Water Proofing Treatment and Ordinary Maintenance in Residential & Non-Residential Buildings at Collectorate Bemetara/Judge Qtr. Bemetara/GAD Qtr. Bemetara/Rest House Bemetara/Circuit House Bemetara /PG Collage Bemetara/Division Office Bemetara & Jail Building Bemetara Under Sub Division Bemetara
S.N. Depar- ment SOR Year ITEM PARTICULARS OF ITEMS QTY UNIT RATE AMOUNT
1 PWD Building 2015 16.36 Dismantling terrazzo or mosaic or glazed vitreous or patent cement or tiled flooring or dado skirting of any thickness without sub base.
2 PWD Building 2015 16.37 Dismantling lime/ cement plaster or skirting at any height raking out joints and cleaning the surface for plaster including disposal of rubbish within 50 metres lead.
PWD Building 2015 152.24 Sqm 11 1675
3 PWD Building 2015 4.13 Grading roof for water proofing treatment with:
PWD Building 2015 4.13.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
PWD Building 2015 69.42 Cum 3817 264976
4 PWD Building 2015 4.22 Providing Water proofing treatment over Roof, Wall, Chhajjas, Balcony with Diamond Shield and Sealer coat or equivalent at leakage/ seepage area consisting of the operation:
PWD Building 2015 (i) Surface preparation roughening of surface, opening of cracks in 'V' groove in size of 5mm x 10m (WxD), filling of cracks with putty of Diamond shield with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/ Nylon brush. Removing all dust particles and washing with adequate water to clean completely
PWD Building 2015 (ii) Providing and applying 1st coat of diamond shield or equivalent compound (having two component dry powder 80% Chemical 20% (chemical having 30% solid contents) making flexible waterproof and protective modified mortar with minimum thickness 70-80 micron after proper mixing of both the parts of compound along with laying of fiber glass mesh (of weaving size of 10x10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to set in natural air for minimum 2 Hrs. After 1st coat apply 2nd coat with minimum thickness 100 micron of the same compound. Allow the 2 coat to set in natural air for minimum 4 Hrs. Total consumption of the diamond shield or equivalent in both coat should be @ 17.90 kg for 10sqm area.
PWD Building 2015 iii) Over the above layers providing and applying 1st coat of sealer compound (Single component High Build elastomeric, flexible, pure acrylic waterproofing membranes having solid content of 65%) minimum 50-60 micron and allow it to set in natural air for minimum 2 Hrs. After 1st coat apply 2nd and final coat 120-140 micron of sealer compound and allow it to set in natural air for minimum 4 Hrs. Consumption of Sealer compound should be @ 5.40 kg per 10 sqm area. The final area appearance of the coating will be milky white
PWD Building 2015 (iv) The treated area should be cure with water for 48 hrs by flooding the surface. All above operations to be done in order
PWD Building 2015 1930.66 Sqm 421 812808
5 PWD Building 2015 9.61 Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work on face of building. (Frame to be paid separately)
PWD Building 2015 9.61.2 4mm thick
6 PWD Building 2015 17.1 Repairs to plaster in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls with cement mortar 1:4 (1 cement : 4 fine sand) complete including disposal of rubbish to the dumping ground within 50metres lead :
PWD Building 2015 17.1.1 Thickness upto 15mm
7 PWD Building 2015 7.5.4 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand)
PWD Building 2015 7.3 Cum 3263 23820
8 PWD Building 2015 3.1.3 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
9 PWD Building 2015 3.2.1 Providing and laying nominal mix reinforced cement concrete with crushe stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). 2.9412 Cum 4163 12244
10 PWD Building 2015 3.12.1 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:Thermo-Mechanically treated bars FE 415 629 Kg 54.5 34281
11 PWD Building 2015 18.25.1 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia 20 Each 68.5 1370
12 PWD Building 2015 18.13.1 Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete:Flat back half stall urinal of size 460x380x250mm 4 Each 1776 7104
13 PWD Building 2015 2.1.13 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.88 Sqm 294 847
14 PWD Building 2015 8.77.1 Providing and fixing antique/ SS finished brass butt hinges with antique/ SS polished MS screw complete: 125x85x5.50mm (Heavy Type) 11 Each 256 2816
15 PWD Building 2015 8.79.1 Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete:300x16mm 11 Each 496 5456
16 PWD Building 2015 8.100.1 Providing and fixing M.S. bright finished or black enameled door latch with necessary iron screws:300x20x6mm 6 Each 53.5 321
17 PWD Building 2015 8.102.1 Providing and fixing M.S. bright finished or black enameled Tower bolts (Barrel type) with necessary iron screws: 250 mm 6 Each 34.5 207
18 PWD Building 2015 8.103.1 Providing and fixing M.S. bright finished or black enameled handles with necessary iron screws:125 mm 6 Each 51 306
19 PWD Building 2015 9.16.2 Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Angle-iron frames 20 Kg 73.5 1470
20 PWD Building 2015 9.6.2 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 20 Kg 68 1360
21 PWD Building 2015 11.1.2 Providing and making 6mm thick cement plaster of mix:In Cement mortar 1:4 (1 cement : 4 fine sand) 40.92 Sqm 87 3560
22 PWD Building 2015 11.2.4 Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) 37.2 Sqm 91.5 3404
23 PWD Building 2015 11.3.4 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand) 29.25 Sqm 107 3130
24 PWD Building 2015 12.7.1 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size upto 200x300mm 27 Sqm 587 15849
25 PWD Building 2015 12.9.1 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete Size 300x300mm 16.5 Sqm 692 11418
26 PWD Building 2015 9.13 Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer. 40 Kg 75 3000
27 PWD Building 2015 12.10.1 Providing and laying rectified ceramic glazed floor tiles of size 300x300mm and above conforming to IS : 15622 of approved make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. Size 300x300mm 21 Sqm 858 18018
28 PWD Building 2015 18.4.1 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White pedestal type 3 Each 2882 8646
29 PWD Building 2015 17.1.1 Repairs to plaster in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls with cement mortar 1:4 (1 cement : 4 fine sand) complete including disposal of rubbish to the dumping ground within 50metres lead : Thickness upto 15mm 45 Sqm 132 5940
30 PWD Building 2015 18.7.1 Providing and fixing 10 litre capacity P.V.C. low level flushing cistern conforming to IS : 7231, with all fittings and fixtures complete.White 8 Each 729 5832
31 PWD Building 2015 18.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Long pattern W.C. pan of size 580 mm 4 Each 2459 9836
32 PWD Building 2015 18.15 squatting plate urinal with an integral rim longitudinal flushing pipe, standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required : 5 Each 2014 10070
33 PWD Building 2015 18.20.1 Providing and fixing stainless steel AISI-304(18/8) wash basin with C.I.brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :Size 450x380 mm 3 Each 3876 11628
34 PWD Building 2015 18.17.1 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x450 mm 5 Each 1430 7150
35 PWD Building 2015 18.76.1 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.75 mm dia pipe. 60 Mtr. 182 10920
36 PWD Building 2015 18.76.2 110 mm dia pipe. 30 Mtr. 267 8010
37 PWD Building 2015 19.4.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15 mm nominal outer dia .Pipes. 30 Mtr. 110 3300
38 PWD Building 2015 19.4.2 20 mm nominal outer dia .Pipes. 20 Mtr. 151 3020
39 PWD Building 2015 19.4.3 25mm nominal outer dia .Pipes. 10 Mtr. 199 1990
40 PWD Building 2015 19.8.1 Providing and fixing concealed in wall G.I. pipes medium class complete with G.I. fittings and clamps, including painting with anti corrosive bitumastic paint, cutting chases, making good the walls etc. and testing of joints complete:15 mm dia nominal bore 20 Mtr. 188 3760
41 PWD Building 2015 19.8.2 20 mm dia nominal bore 20 Mtr. 221 4420
42 PWD Building 2015 19.8.3 25 mm dia nominal bore 25 Mtr. 297 7425
43 PWD Building 2015 19.13.1 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (250 grams) 10 Each 185 1850
44 PWD Building 2015 19.13.3 Stop cock (350 grams) 10 Each 237 2370
45 PWD Building 2015 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 1000 Ltr. 7.3 7300
46 PWD Building 2015 7.5.4+7.6 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 25.199999999999996 Cum 3384 85277
47 PWD Building 2015 8.12.3 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I),decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf) 7.56 Sqm 1832 13850
48 PWD Building 2015 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. 80 Kg 67.5 5400
49 PWD Building 2015 14.9.1 Distempering with acrylic washable distemper to give an even shade On new work (Two or more coats) 122.5 Sqm 38 4655
50 PWD Building 2015 14.10.1 Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade.On new work (two or more coats) 90 Sqm 44.5 4005
51 PWD Building 2015 14.12 Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete. 168 Sqm 23 3864
52 PWD Building 2015 14.13 Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even. 168 Sqm 94.5 15876
53 PWD Building 2015 14.14.1 Finishing walls with water proofing cement paint of required shade to give an even shade.On new work (Two or more coats applied @ 3.84 kg/10 sqm) 360 Sqm 41 14760
54 PWD Building 2015 14.16.1 Painting exterior surface with PREMIUM ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 150 Sqm 74.5 11175
55 PWD Building 2015 14.22.1 Painting on new work (two or more coats) to give an even shade with:Satin synthetic enamel paint 75.60000000000001 Sqm 55 4158
56 PWD Building 2015 9.6 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
57 PWD Building 2015 10.1 Providing corrugated G.I. sheet roofing including vertical/ curved surfaces fixed with galvanized iron, J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead including painting with primer and paint on overlapping of sheets complete excluding the cost of purlins rafters and trusses. (Zinc coating not less than 272 gms/sqm)
58 PWD Building 2015 10.1.2 0.80 mm thick sheet (weight 7.03 kg/m2)
59 PWD Building 2015 Sqm 810 75330
60 PWD Building 2015 18.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required :
18.1.1 White Long pattern W.C. pan of size 580 mm 3 Each 2459 7377
Sub-Engineer Sub Divisional Officer Executive Engineer PWD (B&R) Division Bemetara
PWS (B&R) Sub Divi. Bemetara
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.14 MB
8402132677374491497_192644_Affidavit.docx
NIT • 0.01 MB
1938303982762885312_192644_BID-CAPACITY-2.docx
NIT • 0.03 MB
70814891604804925_192644_English Notice Less than 1 Crore.docx
NIT • 0.03 MB
2510537258274134505_192644_Latest A_ 2.doc
NIT • 0.16 MB
3968552035022037544_192644_Latest NIT APPENDIX 2.doc
NIT • 0.32 MB
2032338134409863970_192644_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
9156321281447324403_192644_NIT Water proffing 20.xls
BOQ • 0.05 MB
Download all tender documents and submit your bid