Loading…
Loading…
Tender Value
₹8.0 Cr
EMD Value
₹5.5 L
Closing Date
24 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS
13 conditions · 2 needing a document upload
The Tender Cost is more than 50 Lakhs, Hence eligibility criteria is applicable. The Firm has to submit the Annexure VIB as per the format mentioned in GCC 2022 duly signed by CA along with balance sheet & profit and loss statement duly signed by CA. Terms and conditions will be as per GCC 2022 with latest amendments.
The Tender Cost is more than 50 Lakhs, Hence eligibility criteria is applicable. The Similar Type of work is:- Supply, installation, commissioning & testing of Fire Detection & Alarm System OR Fire Detection & Alarm and Suppression System OR Any Indoor or combined Indoor & Outdoor Signal or Telecom or S&T work which include supply, installation, testing & commissioning of Fire Detection & Alarm System OR Fire Detection & Alarm and Suppression System
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No PVC clause is applicable. Consignee of the tender is SSE(SIG)Warora Maintenance period is 12 months from the actual date of completion of work.
Provision of Automatic Fire detection and Alarm system (AFDAS) at remaining stations & Huts over Nagpur Division
14-2026-SNT-AFDAS
14-2026-SNT-AFDAS
Open
Works - General
11 Months
Nagpur, Maharashtra
₹0
₹5.5 L
24 Feb 2026
27 Jan 2026
40 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 7,45,60,773.28 | ||
| — | 94.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable, Fire Alarm control Panel with LCD display complying to RDSO/SPN/217/2025 Ver 3.1 or latest moduar, 1 loop (minimum 125 detector/devices per loopexpandable to 2 loops) with 320 Character with soft keys for displaying alarm, events and operating functions, Day/Night operation function, Remote maintenance service feature etc. The panel should be multi-protocol i.e. able to support at least 2 different makes of addressable detectors. The panel should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The panel shall capable to operate on 230 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condition. Panel should be Vds Certified. (Insp AGency-RDSO) | — | — | — | 61,52,399.64 | |
| — | 1794.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of Analogue Addressable Multisensor Detector complying to RDSO/SPN/217/2025 Ver 3.1 or latest As per latest VDS approved/Listed. (Insp AGency-RDSO) | — | — | — | 58,17,296.16 | |
| — | 94.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of Manual call points, complying to RDSO/SPN/217/2025 Ver 3.1 or latest As per latest VDS approved/Listed.(Insp AGency-RDSO) | — | — | — | 4,78,397.96 | |
| — | 6550.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of Resettable, Analogue Type Liner Heat Sensing (LHS) Cable complying to RDSO/SPN/217/2025 Ver 3.1 or latest As per latest UL or FM of LPCB approved/Listed.(Insp AGency-RDSO) | — | — | — | 90,19,743 | |
| — | 94.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of LHS Interface Module with all accessories for single stretch, complying toRDSO/SPN/217/2025 Ver 3.1 or latest As per latest UL or FM of VDS of LPCB approved/Listed.(Insp AGency-RDSO) | — | — | — | 1,22,81,617 | |
| — | 94.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of Aspiration (Air Sampling Type) Detection unit complying to RDSO/SPN/217/2025 Ver 3.1 or latest As per latest UL or FM of VDS of LPCB approved/Listed.(Insp AGency-RDSO) | — | — | — | 2,47,03,658.72 | |
| — | 6550.00 | — | — | ||
| — | 188.00 | — | — | ||
| — | 188.00 | — | — | ||
| — | 94.00 | — | — | ||
| — | 12100.00 | — | — | ||
| — | 188.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
annexureSchC.pdf
RDSOTANFIRE.pdf
LocationofAFDAS.pdf
14-2026-SNT-AFDASTD.pdf
annexureSchC.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .