Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Oct 2024, 6:00 pmClosed
GE (EAST) LUCKNOW
GE EAST LUCKNOW PIN 226002
REPAIR MAINT REPLACEMENT OF OLD ENERGY METER METER BOX SUBMAIN WIRING EARTHING AND CONNECTED WORK OF OTM MD ACCN IN AREA OF AGE EM UNDER GE EAST LUCKNOW
2024_MES_668658_1
GE/E/LKO/T-32 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (EAST) LUCKNOW
₹50,000
Yes
2 Dec 2024
31 Aug 2024
10 Oct 2024
31 Aug 2024
3 Oct 2024
14 Sept 2024
Amount
Taking down carefully by disconnecting Electrical connection and unscrewing from boards/outlet boxes, U/S electric meters of any locations and deposited to MES store yard as per bldg inventry by sub div and complete all as specified and directed.
Supply, installation, testing & commissioning of of 1 Phase, 2 Wire, Energy Meters complete all as specified and directed
Supply, installation, testing & commissioning of of 3 Phase, 4 Wire, Energy Meters complete all as specified and directed
Supply, installation, testing & commissioning of 3 Phase CT/VT Operated Energy Meters with a range of 20-100 Amp, with provision for CT/VT of the required ratio, along with required connections complete all as specified and directed
Supply, installation, testing & commissioning of 3 Phase CT/VT Operated Energy Meters with a range of 100-160 Amp, with provision for CT/VT of the required ratio, along with required connections complete all as specified and directed
Testing of Jumping/Fast & Slow Running complaint meter by a) Fixing a master meter in series with the faulty meter. b) Monitor and record readings from both the faulty meter and the master meter over a period of five consecutive days. c) Submit the readings from the five-day monitoring period to the Subdivsion. d) Upon completion of the monitoring period, remove the master meter from the series connection. Restore the original configuration of the metering system. Note : Master meter will be provided by the contractor including all Electrical Connection complete all as specified and directed
Supply & fixing concealed sheet metal enclosure for Electric meter space one meter with transparent fiber glass door with seal & water and fire proof as per sample. Note:- Quoted rate included for cutting wall, plaster, matching color wall, and good finishing complete all as specified and directed
Refixing only Electrical meter including all accessuries fittings complete Note:- servicelable meter issued MES store complete all as specified and directed
S&F in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volt, 04 way with 200 Amp rated copper bus bar with double door, IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
S&F in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volt, 08 way with 200 Amp rated copper bus bar with double door, IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fixing as in repair MCB DB TPN (double door) 4 Ways, vertical type, IP 43, 415 Volts including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed by the Engr-in-Charge.
Supply and fixing as in repair MCB DB TPN (double door) 8 Ways, vertical type, IP 43, 415 Volts including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed by the Engr-in-Charge.
S&F in replacement MCCB four pole 415 volts 200 Amps repturing capacity 25KA complete all as specified and directed
S&F in replacement MCCB four pole 415 volts 160 Amps repturing capacity 25KA complete all as specified and directed
S&F in replacement MCCB four pole 415 volts 125 Amps repturing capacity 25KA complete all as specified and directed
S&F in replacement MCCB four pole 415 volts 100 Amps repturing capacity 16 KA complete all as specified and directed
S&F in replacement MCCB four pole 415 volts 63 Amps repturing capacity 16 KA complete all as specified and directed
Supply and fixing in repair MCB TPN, 40 to 63 Amps, 240 Volts complete all as specified and directed
Supply and fixing in repair MCB SPN, 32 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as specified and directed
Supply and fixing in repair MCB SP, 10 to 32 Amps, 240 Volts , breaking capacity 10KA complete all as specified and directed
M&L for wiring with wire of size 1.5 sqmm single core with PVC insulated FRLS multistranded copper conductor for working Voltage 1100 V incl taking down old complete complete all as specified and directed
M&L for wiring with wire of size 2.5 sqmm single core with PVC insulated FRLS multistranded copper conductor for working Voltage 1100 V incl taking down old complete complete all as specified and directed
M&L for sub main wiring with 1.5 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to earth incl taking down old cable complete all as specified and directed .
M&L for sub main wiring with 2.5 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to earth incl taking down old cable complete all as specified and directed .
M&L for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to earth incl taking down old cable complete all as specified and directed .
M&L for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to earth incl taking down old cable complete all as specified and directed .
M&L for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to earth incl taking down old cable complete all as specified and directed .
Supply & fix sheet metal enclosure indoor type of size 0.9 x 0.9 x 0.2 mtr suitable to fix on wall/floor made out of 2mm thick CRCA sheet having independent compartments suitable for single phase energy meters and MCB provided with front hinged shutters with lockable arrangements and clear glass to visualize the meter reading without opening the compartment with sufficient working space in compartment prewired with single core PVC insulated and sheathed FRLS stranded copper conductor wire of suitable size from bus bar to meter compartment 08 Nos duly crimped with copper thimbles, duly powder coated complete incl taking down old meter panel complete all as specified and directed and consisting with the following :- (a) Copper Bus bar for 3 phase 4 wire system of 4 x 200 Amps rated insulated copper strip mounted on resin cast insulators in independent compartment having front openable shutter - One set. (b) Incoming MCCB, four pole, 415 volts, 125 Amps, 25 KA with adjustable Overload setting Ir = (0.8 to 1.0)xIn - One No. (c) Outgoing MCB SPN, 40 Amp,10 KA C-Curve - 07 Nos.
Materials and labour for repairing of the earthing complete with diging and filling the salt and charcole 5-10kg refiling sand including chamber plaster, providing the RCC cover of the required size including all neccessary work as per direction.of Eng-in-charge complete all as specified and directed
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wir 4 sqmm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
QUALITY CONSTRUCTIONS CO (BID ID -3127324)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .