Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC 64 SHAHEED UDHAM SINGH MARKET NEAR OLD BUS STAND BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.1 L+₹36,602 (1.69%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹22.8 L+₹1.1 L (5.19%)Rejected-Finance 1000 PUDA MODEL TOWN PHASE 5 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹23.7 L+₹2.0 L (9.05%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹26.0 L+₹4.3 L (19.6%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
8 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Sachin H Chavan IDSE
Garrison Engineer (North) Bathinda Mil Stn
COMPREHENSIVE MAINT TO CERTAIN BUILDINGS IN AIR FIELD UNDER AGE B/R III OF GE NORTH BATHINDA AT BATHINDA MIL STN
2021_MES_420662_1
8935/NIT-58/20-21
Open Tender
Civil Works
Item Rate
152 days
GE North Bathinda Mil Stn
Class D
9 documents required · 9 mandatory
₹500
GE (North) Bathinda
₹59,000
Yes
16 Mar 2021
10 Feb 2021
10 Mar 2021
10 Feb 2021
8 Mar 2021
24 Feb 2021
10 Feb 2021 - 16 Feb 2021
60 days
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply & fixing aluminium anodised frame, made out of aluminium section, for doors, windows, ventilators with one or more rebate and for sliding window shutter including jointing cleat for fixing etc. including making good disturbed wall surfaces (brick, plastering, tiles and painting work as per existing) complete all as specified and as directed by Engineer-in-Charge. Note :- Weight of each section shall be physically ascertained through a board of officers convened by Accepting officer and payment shall be made only after the actual weight at site.
Supply & fixing anodised aluminium door shutter, made out of aluminium section weighing 0.55 Kg/mtr, including necessary joining cleats, glazing clips, rubber neoprene packing, suitable size of aluminium handles 2 Nos and aluminium hinges 03 Nos in each door (size of handle and hinge as directed), anodised aluminium snap beading, screws etc including fixing glass or particle board complete all as specified and directed by Engineer-in-Charge. Note :- Aluminium chowkhat frame, glass and particle board shall be measured and paid separately under appropriate item of BOQ.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply & fixing anodised aluminium window shutter sliding type without sash bars, made out of aluminium section weighing 0.55 Kg/mtr, including necessary joining cleats, glazing clips, rubber neoprene packing, suitable size of aluminium handles 1 No and provision of interlocking system (size of handle as directed), anodised aluminium snap beading, screws etc complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium channel frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass (supply only) shall be measured and paid separately under appropriate item of BOQ.
Supply only 5.5 mm thick sheet glass ordinary quality in squares / retangular exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge. Note :- Labour for fixing and fixing material shall be included in the main item of shutters.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and Supply & fixing new 4mm thick sheet glass ordinary quality in squares / retangular (including cutting of glass as per site requirement) exceeding 0.5sqm in each pane and fixed in any type of doors/windows with fixing material as required complete all as specified & directed by Engineer-in- charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and Supply & fixing new 3mm thick sheet glass ordinary quality in squares / retangular (including cutting of glass as per site requirement) not exceeding 0.5sqm in each pane and fixed in any type of doors/windows/ventilators with wooden bead/pin tacked/with oil putty etc. as required or as directed including cutting of glass as per site requirement complete all as specified & directed by Engineer-in- charge.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out 5mm thick plain clour PVC sheet reinforced with MS square tube including painting of edges to match with sheet, all as specified & shown in relevant drawing of item No. 8095 in MES Schedule SSR-2010 (Part-II), fixed in opening using MS screw 75mm long with PVC fastener including making good disturbed wall surfaces (brick, plastering, tiles and painting work as per existing) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made solid core PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tubes of 19mm gauge thickness and size of 19mmx19mm for stiles and for top and bottom rails 15mmx15mm. MS frame shall have a coat of red oxide primer of approved make and shall be covered with heat moulded plain colour PVC sheet, 'C' channel of size 30x50mm forming stiles and 5mm thick wide PVC sheet strip of 20mm width stuck inside with solvent cement for stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and 10mm (5x2mm) thick, 20mm thick PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive and an additional 5mm thick PVC strips of 20mm width is to be stuck on interior side of C channel using PVC solvent adhesive as per manufacturer's instructions, door to be fixed to frame with and including 3 Nos MS powder coated butt hinges heavy duty of size 75mm long x 25mm wide and 2mm thick and 32mm long steel screws drilled suitable to pass through both the walls of the MS tube complete all as specified in SSR-2009 (Part-I, specifications) & shown in relevant drawing of item No. 8080 in SSR-2010 (Part-II, rates). The width of stiles & rails will be in proportion to the width of the door shutter as specified in SSR-2010 (Part-II). complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing Aluminium handles, cast type, anodised 125mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing in replacement aluminium (Die cast) body door closer hydraulically regulated, designation No 3, universal type suitable for door shutter of 851 to 1000mm in width and weight between 61 to 80 Kg, ISI marked complete all as specified & directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
Material and labour for steel wire fabric mesh not exceeding 4 Kg/ sqm in weight, Welded to steel or fixing to wood members including welding and fixing material complete all as specified and directed by Engineer-in-Charge.
Material and labour for Hexagonal wire netting (Chicken wire mesh) 10 mm apparture and 0.63 mm dia of wire, fixing to steel or wood members complete all as specified and directed by Engineer-in-Charge.
Taking down carefully existing mild steel sliding gate/door (Hanger gate) of size exceeding 30sqm but not exceeding 40sqm each panel, height of gate 8.5m (appx), repair to sliding channel (rail), wheel and all other small steel article by welding and replacement at site in any position including oiling / greasing, alignment / adjustments as easing to slide etc and after complete repair upto entire satisfaction of Engineer-in-charge gate shall be refix in original position complete all as specified and as directed by Engineer-in-charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof covering complete all as specified & directed by Engineer-in- charge.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, with grade of zinc coating 275gms in roofs, walls etc. fixed with L type or J type or cranked hooks bolts complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 3mm thick fibre glass reinforce transulcent corrugated sheeting with two corrugation on side lap fixed with coach screw and wahser in roof wall etc complete all as specified and as directed by Engineer-in-Charge.
Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size bricks (old serviceable bricks obtained from demolition/dismantled item shall be reused ) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces (internal surface), finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- WPC shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement including demolition of cement concrete (unreinforced, existing plinth floor, hard standing etc, only damage area of plinth) of any description and in any position, same material using as a hard core, filling in down surface/depressions area which occurs during the process and the surface prepared in leveled well ramming including watering as required and consolidation with Durmat/hand roller, rolling to required gradient and camber and upto entire satisfaction of Engineer-in-charge, balance unused material/dabries removing rubbish from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge. Note :- Extra hard core where required for leveling the surface same shall be measured and paid separately under appropriate item of this schedule.
Dismantling of bricks, PCC tiles, interlocking tiles laid flat (except sub base ) of any description or thickness in floors, aprons etc. laid dry including removing sand and tiles from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base or for leveling course of floor (base making good by applying PCC over existing sub base as per required thickness where surface down from existing required level/damage sub base, to maintain level for interlocking tiles floors) complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and pigment (any coloured as directed), prepolished & preglazed, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge. Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
Supply only Fazilka/Zera (or any other approved sources) fine sand without silt for filling under interlocking tiles and the interstices etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in foundation filling, bed block, for embedded fencing posts, coping/packing around chequered tiles/interlocking tiles/PCC jalli & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in kerb stone, quoin blocks, apex stones, boundary pillars, bed plates, bonders ( for stone walling), etc with plain fair faces, chamfers, weatherings, slightly rounded or chamfered angles and throating etc including form work and earth work and laying and setting in cement mortar (1:4) including dismantling of old damaged kerb stone and removing the debris from site complete all as specified & directed by Engineer-in- charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. including removing from site/keeping aside for reuse (serviceable as good condition as directed) complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. including removing from site/keeping aside for reuse (serviceable as good condition as directed) complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as required) and making good disturbed surfaces of walls including cutting and threading of existing pipe any dia for insertaion of tee branch including hole in wall to pass the pipe out side for connection as per site requirment complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as required) and making good disturbed surfaces of walls including cutting and threading of existing pipe any dia for insertaion of tee branch including hole in wall to pass the pipe out side for connection as per site requirment complete all as specified and as directed by Engineer-in- charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from the site to a distance not exceeding 100 metre and deposited as directed complete all as directed by Engr-in-Charge
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (rendering) in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile including and exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (light shade) 08mm to 10 mm thick square or rectangular area of each tile not exceeding 0.36 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm with integral foot rests, fixing in existing trap (excluding flushing cistern, flush pipe above floor), including demolation of tile, PCC, taking out mass concrete filling and re filling lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing upto entire satisfaction of Engineer-in-charge before filling concrete and making good with 30mm thick cement concrete (1:2:4) type B0 finished rough as a sub base to recieved tile work complete all as specified and as directed by Engineer-in- charge. (NOTE : Tile work with screed shall be measured and paid separately under appropriate item of this schedule.
Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern (white colour) with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe, PVC Connection 450 mm long with PTMT nuts suitable for 15mm bore pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement PVC (SWR) floor trap suitable for 100/110mm bore pipe laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting including fixing only pillar tap/mixer valve (new or serviceable old pillar tap/mixer valve as per site condition ) complete all as specified and as directed by Engineer-in-Charge. (Note :- Mixer Valve / Pillar tap if required new same shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply only pillar tap cast copper alloy with capstan head, chromium plated, fancy type, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply & fixing in replacement vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, complete all as specified & directed by Engineer-in-charge.
Supply & fixing in replacement 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement bib tap cast copper alloy, chromium plated fancy type, long body with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in replacement stop valve/angle valve cast copper alloy, chromium plated fancy type screwed down high pressure with crutch or butterfly handle, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock/angle valve shall be as given in SSR or in relevant IS.
Supply & fixing in replacement brass chromium plated/stainless steel tubular towel rail 20mm dia 'D' type, 600mm long between flanges fixed to plug , bracket with chromium plated brass screws all as specified and directed by Engineer-in-Charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply only ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply only gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply & fixing in replacement 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors including dismantling/taking down/out old pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends without access door (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Taking out sealing compound from partially field joints of size 10mm wide upto complete depth of filled material (approx 30mm deep) from of rigid concrete pavements/slab (thickness of slab150mm), cleaning of joints with brushes and fanning with compressor air to remove all loose dirt/dust etc. and priming and refilling the joints with new sealing compound grade 'A' complete all as specified and directed by Engineer-in-Charge. Make :- M/S Fosroc Chemicals Ltd./M/S STP Ltd/ M/S Pidilite Indiustries Ltd/ M/S Roff Chemicals Ltd
Material and labour for complete removal of existing thermoplastic paint (any layers of existing treatment ) from runway, helirunway termic area by scraping with steel patti, wire brush and high pressure compressor jet complete all as specified and as directed by Engineer-in-Charge. NOTE : - After Complete removal to old existing treatment, the surface shall be passed in writing by the Enigineer-in-charge.
Material & labour for marking on runway/helirunway/road /pavements, like lines, dashes, arrows, letters or figures etc. using Hot applied retro-reflective thermoplastic road marking paint (in any colour as direccted like white, golden, yellow, orange black etc.) confirming to MORT & H (clause 803.4) with 8% glass beads, using special applicator machine with heating arrangement upto 160 °C including cleaning and drying the existing road surface to ensure dust, oil grease and moisture free surface before applying the paint complete all as specified and as directed by Engineer-in-charge. Make of paint : Shivalic / Kothari / Jayanti / Swastic
Material and labour for Preparation of old decorated surfaces (plastered/unplastered) of ceiling by removing / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make the surface even and smooth upto upto entire satisfaction of Engineer-in-charge and after preparing the surface applying one coat of lime white wash with paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old decorated surfaces (plastered/unplastered) of walls/pillars /cornices by removing / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean, washing down with water including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth upto entire satisfaction of Engineer-in-charge, and after preparing the surface applying one coat of cement base paint with paint brush or roller brush, as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old decorated surfaces (plastered/unplastered) of walls/pillars /cornices by removing / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean, including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make the surface even and smooth upto entire satisfaction of Engineer-in-charge, and after preparing the surface applying one coat of oil bound distemper (washable) by using paint brush or roller brush, as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old surfaces (plastered / unplastered) of walls/pillars /cornices by removing / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean, including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make the surface even and smooth upto entire satisfaction of Engineer-in-charge, and after preparing the surface applying one coat of weather proof exterior emulsion paint (wheather coat Apex, 100% exterier grade), as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or steel wire brushing and after preparing the surfaces applying two coats of oil bound distemper over a coat of priming paint (primer) preparatory to distempering, to match the existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars/cornices with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as approved tint/colour with using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish complete as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power point) complete including fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator, sunken boxes etc but except concealed conduit complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing concealed PVC rigid conduit, but new Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick), 3mm thick bakelite plastic laminated sheet for mounting of switches and socket, fan regulator, for light /fan/bell point, controlled by one switch, switches/socket fixing with brass screws & cup washers and covering with and including frame, including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 76 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 76 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn in existing PVC rigid conduit, but new Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick), 3mm thick bakelite plastic laminated hylem sheet for mounting of switches and socket, for one socket out let 15/16 Amps point controlled by one switch (on indipendent board), switches/socket fixing with brass screws & cup washers and covering with and including frame, including provn of 2.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Taking down carefully copper/aluminum point wiring (light, fan, socket or power point) complete including fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator including rusted/broken concealed conduit and sunken boxes etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick), 3mm thick bakelite plastic laminated hylem sheet for mounting of switches and socket, wiring for light /fan/ bell point controlled by one switch (on indipendent board), switches/socket fixing with brass screws & cup washers and covering with and including frame, including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 81 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 81 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick), 3mm thick bakelite plastic laminated hylem sheet for mounting of switches and socket, wiring for one socket out let 15/16 Amps point controlled by one switch (on indipendent board), switches/socket fixing with brass screws & cup washers and covering with and including frame, including provn of 2.5 Sqmm FRLSH PVC insulated solid copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 5/6Amps, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing switch piano flush type (ISI marked), Bell Push, 5/6Amps, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose type (ISI marked), 2 in 1, 3/5 pin 5/6 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose type (ISI marked), 2 in 1, 3/5 pin 15/16 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 15/16Amps, single pole, one way complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing batten holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 5/6Amps, 250 volts including LED lamp lumeno of 9 watt suitable for B-22 based holder complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stepped type (1-4/5), electronic Fan regulator (two module), 100 watt, 250 volts, fixed on laminated sheet suitable for ceiling fan complete all as specified by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing in replacement electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection and testing, complete all as specified and as directed by Engr-in-charge.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through existing PVC conduit, independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including taking out old sub main wiring of any conductor any size from conduit and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire shall be measured as one RM length for payment.
Material and labour for sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for sub main wiring with 2.5 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 2.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-(i) Three run of 2.5 sqmm copper wire and one run conduit shall be measured as one RM length for payment. (ii) Wiring fixing in replacement at any height of roof/hanger roof/tower/hanger wall and cost for arrangement shall be included in the unit rate nothing shall be paid extra on this account.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) TPN, 4 Way 240V (8+12 modules), double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement (Concealed with wall) single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply including taking down old unserviceable enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 415 volts AC supply, 63 Amps, FP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement wall mounted LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories fitting arrangements including electric connection including taking down old unserviceable light fittings any type at any site as directed complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No BLRB 18W CWc and BLRB-DB 118 of Bajaj / LT8-20-865-2 and DMLN1LT8-16 of Crompton / PHOTONULTRA 1213 T8SSTL 18W LED 865SPC and REGALBATTENT 8UPTO 1X22W SSBSWH of Havells
Supply and fixing in replacement LED light fiting 9/10 watt (100 lumens per watt), appx 2 feet long with in built driver, complete fitting ready to use in all respect with tube rod and all other accessories fitting arrangements including electric connection including taking down old unserviceable light fittings any type at any site as directed in any position complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No BCLSB 10WH of Bajaj / LCTL-9-CDL of Crompton / LUMILINEBS9 WLED 865 SPCWH of Havells
Supply and fixing Sleek Pressure die cast aluminium housing/body, heat resistant clear glass, LED lens for wide beam, energy saving, IP65/66 protection, not less than 5700K, better optics for uniform distribution street/Roadway luminaire with high power LED 25 watt complete fitting with driver, LED strip and all other accessories etc, suitable for 40/32mm OD entry for direct mounting on pipe bracket, fixing on poles/along wall with and including brackets made out of GI tubing light grade 40mm dia, 2 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing with MS clamp (02 Nos) and nut bolts, including before fixing applying two coats of aluminium paint on bracket and clamp over a coat of red oxide primer, including making electric connection with using twin core copper cable of suitable size and including taking down old unserviceable light fitting complete all as specified and as directed by Engineer-in-charge. Make - Cat part No LSTS-25-CDL of Crompton/ BRLEP 25W LED WH of Bajaj / ENDURA PEARL SL25W LED757SASYTOPC of Havells
Supply and fixing energy saving IP65 flood light luminaire, high pressure die cast LED light fitting 150 watt LED, 100 lumens per watt, complete fitting with LED strips and all other accessories and fitting arrangements including connecting electric connection, including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge. Make : Cat part No. LFLN-150-CDL/60 of Crompton / BJFL 150W LED I of Bajaj / PCGLFT1 01 150 of Polycab / HPL LED FL 15060S of HPL Note : Light Fitting fixing in replacement at any height of roof/ceiling/along wall of building/hanger and cost for arrangement for height shall be included in the unit rate nothing shall be paid extra on this account.
Supply and fixing in replacement energy saving IP65 flood light luminaire, high pressure die cast LED light fitting (100 lumens per watt) not less than 5700K, complete fitting with LED strips and all other accessories and fitting arrangements including connecting electric connection, including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge. Make : Cat part No. LFLE-50-CDL of Crompton / BJFL 60W LED I of Bajaj / PCGLF T102 6057 of Polycab /JETA COMPECT OFL50WLED 757LTG of Havells Note : Light Fitting fixing in replacement at any height of roof/ceiling/along wall of building/hanger and cost for arrangement shall be included in the unit rate nothing shall be paid extra on this account.
Supply and fixing LED aviation light luminaire comprising of aluminium housing with polycarbonate enclosure complete fitting with LED and all other accessories including electric connection connecting with using flexible copper wire twin core 23/0.0076mm drawn thr steel conduit including fixing clamps and including taking down old unserviceable light fitting any type complete all as specified and as directed by Engineer-in-Charge. Make :- BGAV 302 LED of Bajaj or equivalent in Havelles /Crompton Greaves/Surya Note : Light Fitting fixing in replacement at any height of roof/tower of building/hanger and cost for arrangement shall be included in the unit rate nothing shall be paid extra on this account.
Material and labour for repair to landing T-lights any make, fixed in landing T of Halipad in existing panel by replacement of 5 watt LED (lamp), base E-27 and glass with gasket including minor repair/loose connection including short length of wire complete all as specified and as directed by Engineer-in-Charge. Make of lamp :- Bajaj / CG/Havelles
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, taking out old pipe and laying new pipe line, for taking out of LT under ground cable and laying of cables or pipes (where provided) for protection of cable or fixing poles and stays etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Taking out old unserviceable under ground LT XLPE/PVC cable of any size from trenches/wall/roof/road/pipe /pole including taking out of brick layer and sand from trenches etc including serviceable brick stack for reuse and balance removing from site complete all as specified and as directed by Engineer-in-Charge. (Earth work shall be measured and paid for separately under appropriate item).
Supply and laying XLPE LT Cable of size 10 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement GI tubing, light grade, 40 mm bore for cable protection, earth strip/earth wire protection in trenches, under floor etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC (1:2:4) as in pit cover and frame (including steel ), PCC chamber pit with PCC (1:3:6) type C-1 using 20mm graded stone aggregate, including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m complete all as specified and shown in electrical plate No. 3 of SSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply and fixing in replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long at roof of building/ESHs at any height including taking down old unserviceable air termination rod any type complete all as specified and as directed by Engineer-in-charge.
Material & labour in repair/replacement for earth continuity conductor or main earthing lead fixed to wall with saddles or chases or buried in ground or drawn in conduit/pipe for loop earthing, down condductor etc. or any other situation as required/directed by using 20 x 3.15 mm copper strip, including taking out old unserviceable/broken earth continuity conductor complete all as specified and as directed by Engineer-in-charge. Note :- Conduit/pipe as required shall be measured and paid separately under appropriate item of BOQ
Supply and fixing in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw complete all as specified and as directed by Engineer-in-charge.
Material and labour for Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity copper strip 20x3 mm (upto test point from earth plate, i.e. 7.5m minimum) by means of GI bolts/nuts/washers and including protected by 40mm dia GI light grade protection pipe from earth plate to test point, Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover and frame, using PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in earthing pit including necessary form work, excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR (Part – I) including taking out/dismantling old unserviceable earthing system complete all as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
M/s Kamal Builders
R B BUILDERS
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .