RequiredOEM Authorization Certificate Bid to RA enabled No Atomic Absorption Spectrophotometer Aas ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TYPE Type of Atomic Absorption Spectrometer (AAS) Double beam Double beam Monochromator type LITRO LITRO Detector Type CMOS CMOS SPECTRAL Source Wavelength - Minimum 185 185.0 Source Wavelength - Maximum 900 900.0 1/6 Accuracy (+/-) 0.1 0.1 Repeatability 0.05 0.05 Diffraction grating (lines/mm) 1800 1800 Wavelength setting and scanning Automatic Automatic Slit width Adjustment Automatic Automatic Slit width range(nm) 0.1 - 2.0 * Resolution (nm/mm) 0.1 0.1 Bandwidth (nm) 0.1 - 2.0 0.1 - 2.0 Focal length (mm) 250 to 299 250 to 299 LIGHT SOURCE Light Source Hollow Cathode Lamp (HCL) * Type of HCL Both Single and Mulitiple Element Both Single and Mulitiple Element Number of Single element HCLs supplied (inclusive in the scope of supply) 10 10 Number of multiple element (alloy) HCLs supplied (inclusive in the scope of supply) 1 1 Measuring modes (K factor and standards) Absorbance
RequiredConcentrat ion (Wavelength
Requiredtime)
RequiredEmission Absorbance
RequiredConcentration (Wavelength
Requiredtime)
RequiredEmission Detectable Elements using single element HCL Cu
RequiredFe
RequiredZn
RequiredMn
RequiredMg
RequiredB
RequiredK
RequiredMo
RequiredCa
RequiredAs Cu
RequiredFe
RequiredZn
RequiredMn
RequiredMg
RequiredB
RequiredK
RequiredMo
RequiredCa
RequiredAs Detectable Elements using multi element HCL Na-K
RequiredCa-Mg
RequiredSi-Al
RequiredFe-Ni
RequiredSr-Ba
RequiredAl-Ca-Mg
RequiredCa-Mg- Zn
RequiredCu-Mo-Co-Zn
RequiredCd-Cu- Pb-Zn
RequiredCu-Fe-Zn-Mn
RequiredCo- Cr-Cu-Fe-Mn-Ni
RequiredCd - Hg - Pb Na-K
RequiredCa-Mg
RequiredSi-Al
RequiredFe- Ni
RequiredSr-Ba
RequiredAl-Ca-Mg
RequiredCa- Mg-Zn
RequiredCu-Mo-Co-Zn
RequiredCd-Cu-Pb-Zn
RequiredCu-Fe-Zn- Mn
RequiredCo-Cr-Cu-Fe-Mn-Ni
RequiredCd - Hg - Pb Measurement level ppm level
Requiredppb level * Lifespan of Single element lamp (mA- Hr) 5000 5000 Lifespan of multi- element/Alloys lamp (mA-Hr) 5000 5000 Number of sockets on Turret 8 8 2/6 ATOMIZER Type of atomizer Integrated Flame Burner & GF Integrated Flame Burner & GF Nebulizer Pt/Ir nebulizer Pt/Ir nebulizer Background Correction D2 Lamp method D2 Lamp method Flame and furnace change over switch Automatic * Burner diameter (mm) 100 100 Coolant Liquid type * Sample volume 5 * Corrosion resistant Chamber Yes * Adjustable aerosol based nebulizer flow Yes * Furnace heating range (Degree celcius) 0 - 3000 * Time for analysis (sample) 10 10.0 GENERIC Display through PC through PC Display type NA NA Test result printing Through external printer Through external printer If inbuilt printer
RequiredType of printer N/A N/A Connectivity USB
RequiredETHERNET
RequiredRS 232 * Safety sensors Pressure sensor
RequiredFlame Sensor
RequiredFlame Ignition Sensor
RequiredBurner interlock
RequiredPower failure protection
RequiredNebulizer Sensor
RequiredAuto ignition Pressure sensor
RequiredFlame Sensor
RequiredFlame Ignition Sensor
RequiredBurner interlock
RequiredPower failure protection
RequiredNebulizer Sensor
RequiredAuto ignition Burner movement (lateral
Requiredhorizontal & height) Automatic Automatic POWER SOURCE Power Supply 230 V A.C ± 10%
Required50 Hz * OPERATING CONDITIONS Minimum Operating Temperature 10 10.0 Maximum Operating Temperature 35 35.0 Operating Humidity (RH) (%) at 40 degree c 80 80.0 ACCESSORIES Type of gas cylinders Nitrous oxide Nitrous oxide Type of Regulators With Heater With Heater 3/6 supplied Number of Regulators Supplied (inclusive in the scope of supply) 3 3 Number of Acetylene Cylinders supplied (inclusive in the scope of supply) 2 2 Capacity of each Acetylene cylinder (Litres) 47 47 Number of Nitrous oxide Cylinders supplied (inclusive in the scope of supply) 2 2 Capacity of each Nitrous oxide cylinder (Litres) 10 10 Gas cylinders confirming to N/A * Gas cylinders having PESO certificate Yes Yes Other accessories (inclusive in the scope of supply) Gas flow control box
RequiredOil Moisture Filters
RequiredSS Exhaust fume hood with blower
RequiredSchematic diagram and instruction manual
RequiredHydride generator
RequiredAuto sampler Gas flow control box
RequiredOil Moisture Filters
RequiredSS Exhaust fume hood with blower
RequiredSchematic diagram and instruction manual
RequiredHydride generator
RequiredAuto sampler Suitable software for connecting PC & Printer (inclusive in the scope of supply) Yes Yes Any other features/accesories covered in scope of supply - * WARRANTY AVAILABILITY OF SPARES warranty (Year) 5 5.0 Spares and Consumables inclusive in the scope of supply Yes Yes List of Items and Quantity of each item included in the offer - * CERTIFICATION Availability of UL/CE Certification as per EN 61010-1:2010 Yes Yes 4/6 Safety requirements for electrical equipment for measurement
Requiredcontrol
Requiredand laboratory use General requirements Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement
Requiredcontrol and laboratory use Yes Yes Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to the specification Yes Yes If yes test report to furnished
Requiredto the buyer on demand Yes * Test Report number and date - * Name and address of the Lab - * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.