| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹38.4 L+₹1.4 L (3.79%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹39.1 L+₹2.1 L (5.63%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹39.4 L+₹2.4 L (6.52%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹40.0 L+₹3.0 L (8.16%)Rejected-Finance H NO 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500015 | HYDERABAD | TELANGANA | 500015 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹47.4 L
EMD Value
₹94,800
Closing Date
12 Aug 2023, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME SECUNDERABAD MCEME CAMPUS, TRIMULGHERRY (POST) SECUNDERABAD - 500 015
SPECIAL REPAIRS TO BLDG NO P-155 (COOK HOUSE) OF JCOs CLUB OF MCEME UNDER GE MCEME SECUNDERABAD
2023_MES_610464_1
GE/MCEME/TOK/21 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE MCEME SECUNDERABAD
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹94,800
Yes
12 Sept 2023
24 Jul 2023
18 Aug 2023
24 Jul 2023
12 Aug 2023
7 Aug 2023
Amount
Demolition of Lime concrete / Mud phuska / PCC of any description and in any position not otherwise specifically provided for renewal including removal of demolished material beyond the Md land to a distance exceeding 500mtr not exceeding 1.5KM completed all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in roof padding, complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 10mm thick in cm (1:3) on concrete surfaces of roof padding with integral water proofing compound (water proofing compound to be paid separately ) finished even & smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound, complete all as specified and directed by Engineer-in-Charge.
M&L APP based polymeric membrane minimum weighting 3 kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gm/Sqm) laid on primed surface by forced application over a coat of a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces, complete all as specified and directed by Engineer-in-Charge.
Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, 25mm thick, type B0 (12.5mm graded stone agg) for laying under floor finishes complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified Ceramic coloured tiles, light shade, 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry over and including10mm thick screed bed of CM 1:4 and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured tiles 450x300x7mm thick, in vertical surfaces such as dados,over and including 10mm thick rendering in CM 1:3 to receive tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specificed and as per directed by Engineer-in-Charge.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by Engineer-in-Charge.
Taking down,Chowkhats or frames exc. 1.5 sq. m and n.exc. 4 Sqm each, but with shutters (without taking off shutters from the frames), complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames not exc 1.5 sqm each(without taking off shutters from the frames), etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F prepainted steel windows/ventilators ( ECO–4000 Series Windows (Double Rebate Windows) or equivalent) fabricated from roll framed sections made of galvanized steel colour coated/powder coated (Base steel as per IS-513 “D” quality galvanized as per IS-277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm. Sections for Frame should be of 72x55mm, Section for Mullion should be of 72x50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12x12mm, and Section for Fly Mesh should be of 40x20mm Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter including SS Pivot Hinges–1 set, Seccolor Handle & Seccolor Stay and 4mm Plain Float Glass and Stainless Steel 32 gauge Fly mesh of 25 holes per SqCM and powder coated Grill made of 10mm sq. MS Bars welded at 150mm c/c, 6x12mm MS flat and fixed to window frame with screws , complete all as specified and directed by Engineer-in-Charge. (Make : NCL/TATA/Equivalent)
S&F pressed steel door frame 125 x 60mm with one or more rebats including fixing lugs, hinges, lock strike plate etc complete all as specified and directed
S&F pressed steel door frame 105 x 60mm with one or more rebats including fixing lugs, hinges, lock strike plate, complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping, filling in door frame etc. complete all as specifed and directed.
S & F 2nd class hardwood,Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, complete all as specified and directed by Engineer-in-Charge.
S & F 35 mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on face is covered with decorative face veneer both sides , complete all as specified and directed by Engineer-in-Charge.
S&F of 35mm thick Second class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc. divided in to square with plain chamfered or rounded mitred and rebated sash bars, any numbers, edges of framing plain chamfered or , complete all as specified and directed by Engineer-in-Charge.
S&F 2nd class hard wood 35mm thick, plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, the sizes of members of shutters shall be, etc complete all as specificed and as per directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated surface of wood or wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enemal paint over a coat of pink primer, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F 100 mm long butt hinges extruded aluminium alloy with brass/bronze hinge pin in lieu of mild steel min , complete all as specified and directed by Engineer-in-Charge.
S&F 150mm size aluminium anodised handles, fabricated type , complete all as specified and directed by Engineer-in-Charge.
S&F 150mm long aluminium anodised barrel tower bolt of extruded section , complete all as specified and directed by Engineer-in-Charge.
S & F for Floor door stopper of brass body and tongue, anodised,with hard drawn steel spring, fixed in floor, Overall length of cover plate 140 mm,etc complete all as specified and directed by Engineer-in-Charge.
S&F 300mm long MS ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed by Engineer-in-Charge.
Dismantling boarding, any description fixed in any position with nails, complete all as specified and directed by Engineer-in-Charge.
M & L for 18 mm thick, Plywood, grade BWR, type BB, fixed with screws to timber frame work in repairs, complete all as specified and directed by Engineer-in-Charge.
M & L for 0.9 mm thick, Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
S & F for Butt hinges 75mm in size, medium weight, cold rolled mild steel, and fixed, size of hinges in 25 mm, complete all as specified and directed by Engineer-in-Charge.
S & F for Stainless Steel fency type handles, cast type, polished bright, Size of handle in 100 mm,complete all as specified and directed by Engineer-in-Charge.
S&F 50 mm long Magnet ball catcher made out of PVC fixed to shutter and chowkhats with SS screw all as specified and directed by Engr-in-Charge.
S&F 100 mm size Hasp and staple, Aluminium anodised, wire type, including bolt to hinge plate and fixed with screws complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium snap grid of 605x605mm frame work for ceiling including Hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by Engineer-in-Charge.
M&L for 6 to 7 mm thick Gypsum board panels 600x600mm with PVC laminated on one side and aluminium foil on another side suitably placed in false ceiling grid made of aluminium GI/MS complete all as specified and directed by Engineer-in-Charge. Note: Grid will be measured and paid separately
S&F 1000 Ltr capacity of rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling all as specified in SSR Part-I), etc complete all as specified and as per directed by Engineer-in-Charge.
Taking up or down steel tubing & connections, 15 mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
Taking up or down steel tubing & connections, 20 mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
Taking up or down steel tubing & connections, 25 mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F steel water tubing medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe 15 mm, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F steel water tubing medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe 20mm, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F steel water tubing medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe 25mm, etc complete all as specificed and as per directed by Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required of brick walls and pointed in cement mortar 1:3 for concealed water tubing etc cutting not exc 10 cm girth, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F in repairs chromium plated fancy type stop cock copper alloy 15mm bore screwed down high presure with crutch or butterfly handle screwed both ends for iron pipes, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F in rep CP bib taps cast copper alloy with crutch or butterfly handle, screwed for iron pipe of dia 15mm, fancy type, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F in repairs Gun metal globe or gate valve 20mm bore dia of pipes, with iron wheel head screwed both ends for iron pipe and fixed, etc complete all as specified and as per directed by Engineer-in-Charge.
S&F in repairs 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete, screwed for iron pipe or for brass ferrule of 20mm dia, etc complete all as specified and as per directed by Engineer-in-Charge.
S&F PVC (SWR) 100/110mm bore single socketed pipes in any length with rubber ring joints fixed to wall with pvc clamps including taking down old pipes, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F PVC (SWR) bend/shoe for 100/110mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F in repairs PVC (SWR) gully grap 125/110mm setting and jointing with solvent cement and preparation of trap hole, etc complete all as specificed and as per directed by Engineer-in-Charge.
Low density poly ethylene pipes (LDPE) of pressure rating 6 kg/ cm2 laid in trenches, Bore of pipes in 40mm, complete all as specified and directed by Engineer-in-Charge.
M & L for Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed Bore dia of pipe in 40 mm, complete all as specified and directed by Engineer-in-Charge.
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engineer-in-Charge.
S&F in repair, PVC valveless, 10 litrs, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, etc complete all as specified and as per directed by Engineer-in-Charge.
S & F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms), etc complete all as specified and as per directed by Engineer-in-Charge.
S&F Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), etc complete all as specifed and directed.
S&F in repair Stainless Steel soap dish, any type, fixed to plugs with chromium plated brass screws, complete all as specified and as per directed by Engineer-in-Charge.
S&F CP brass tubular towel rail 600mm long 20mm dia 'D' type in repairs complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel peg set of five hooks as approved by Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous China wash hand basin of size 550 x 400mm white flat back including chromium plated pillat tap, waste coupling, including brackets, PVC waste pipe, including cutting for and pinning in ends of brackets or errecting stand, complete all as specified and as directed by Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed by Engineer-in-Charge.
M&L brick work with sub class 'B' bricks old size straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Taking down of cement plaster on brick or stone walls,/ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick cement plaster in two layers (5mm thick in CM 1:4 with using water proofing compound over 10mm thick in CM 1:6) on external surfaces of brick work or concrete surfaces even and smooth without using extra cement, complete all as specified and as per directed by Engineer-in-Charge.
Supply only Integral water proofing compound, etc complete all as specificed and as per directed by Engineer-in-Charge.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surface on wall, finished even and smooth (without using extra cement), complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for Two coats of Distempering with oil emulsion distemper on newly plastered surfaces of walls over and including two coats of wall care putty over and including a coat of alkali resistance primer including preparation of wall surfaces, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation newly plastered surfaces of wall and cornices and applying two coats of acrylic weather proof painting over and one coat of primer on wall over two coat of wall care putty to make surfaces smooth and good, complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment including prepration of old decorated wall surface and applying two coats of Oil Bound Distemper over and including a coat of primer over and including two coats of wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatement including preparation of old decorated surfaces of wall and cornices and applying two coats of acrylic weather proof painting on wall to make surfaces smooth and good, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of ceiling & applying two coats of oil bound distemper over and including a coat of primer over and including two coats of wall care putty, complete all as specified and directed by Engineer-in-Charge.
M&L RCC type B1 (1:2:4) using 20mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; exc. 200m thick (Horizontal or sloping) Rough finished surfaces of concrete flat, complete all as specified and as directed by Engineer-in-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide, rough finished surface, complete all as specified and as directed by Engineer-in-Charge.
M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, TMT bars,etc, complete all as specified and directed by Engineer-in-Charge.
M & L Granite (of any type) work (table rubbed and polished)20 mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc , etc complete all as specified and as per directed by Engineer-in-Charge.
Rounding off edges of granite platform/urinal partition, etc complete all as specified and as per directed by Engineer-in-Charge.
Dismantling of asbestos cement (corrugated,semi corrugated etc.) sheets in roof coverings complete all as specified and directed by Engineer-in-Charge.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick(TCT) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates, Fe410-W (Gde-E-250) quality-A, complete all as specified and directed by Engineer-in-Charge.
S& F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, etc complete all as specified and directed by Engineer-in-Charge.
M & L Preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base etc., complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes, complete all as specified and as directed by Engr-in-Charge.
M & L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments, complete all as specified and as directed by Engr-in-Charge.
M & L 75mm thick PCC 1:3:6 type C-2 using 40mm graded aggregate as in plinth protection, complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
Dismantling stone slabs and tiles laid dry and pointed of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer-in-Charge.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engineer-in-Charge.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Excavation in trenches n.exc 1.50m wide and n.exc. 1.50m depth and getting out in hard/dense soil , complete all as specified & directed by Engr-in-Charge.
Excavating over areas, n exc 1.5 m deep and getting out in hard rock, complete all as specificed and directed by Engineer-in-Charge.
Returning, filling in incl spreading, leveling, watering and well ramming in layers n. exc 25cm all as specified.as in soft /loose soil, complete all as specified & directed by Engr-in-Charge.
Removing excavated materials n'exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point in soils, complete all as specified & directed by Engr-in-Charge.
M&L Reinforced concrete pipes 200mm dia bore, class NP3, laid and jointed complete with collars laid in trenches and jointed as specified incl demolition and breaking up, complete all as specified & directed by Engr-in-Charge.
M&L for Cement Concrete 1:3:6 type C-2 as concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 200mm dia SWG pipe, complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:4:8, type D2 (using 40mm graded stone aggregated) as in foundations, filling and mass concrete, complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregated) set in CM 1:4 as in benching to manholes/drain surface, complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregated) as in coping incl necessary form work, complete all as specified & directed by Engr-in-Charge.
Demolition of cement concrete of any description in any position (Reinforced), complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:2:4, type B1 (using 20mm graded stone aggregate as in pre-cast cover slabs for manholes incl necessary form work set in CM 1:4, complete all as specified & directed by Engr-in-Charge.. (Reinforcement will be measured & paid separately)
M&L 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces of walls finished the surface even & smooth without using extra cement, complete all as specified & directed by Engr-in-Charge.
M&L for 3.00m dia, 4.5m depth soak pit (PCC block construction) including earth work like excavation in any type of soil, returning filling and removal of soil upto a distance of 100m from starting point. Foundation in PCC, walls, cover slab, rungs, man holes etc all as per CECZ TD Drawing No. TD/ST/748, sheet No 01/01 dt 22 Jan 2011 complete all as specified and as directed by Engineer-in-Charge.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit concealed wiring in walls/PVC conduit on wall including Tee, Junction boxes and provision of 2.0mm thick MS terminal boxes duly painted with red oxide metal primer and covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly including cutting & chasing and making good the disturbed area to match with the existing complete all as specified and directed by Engineer-in-Charge. for One light point controlled by one, one way switch 5 amps, SP
All as per item No. 110 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 110 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 110 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 110 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
Supply and fixing of Switch piano , single pole one way, flush type 5 Amps capacity 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of socket outlet 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing switch socket combination 2 in 1 multipurpose 3 pin 5/15 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of electronic ceiling fan regulator stepped 2M type heavy duty suitable to work on 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed Submain wiring with 4 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including two run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length (For Metal clad socket).
Material and labour for concealed Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (For SPN DBs and AC sockets)
Supply and fixing LED wall mounted batten fitting with polycarbonate housing and integrated electronic driver 1x 20W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply and fixing LED 2x2 light fitting with high performance LEDs 1x 42W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose suitable for mounting with Armstrong/Grid ceiling complete all as specified and directed .
Supply and fixing LED round down light fitting with high performance LEDs 1x 18 W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose suitable for recess mounting complete all as specified and directed .
Fixing only LED light fitting removed from wall/ceiling with flexible copper conductor cable of suitable size all as specified and directed by Engr-In-Charge.
Supply and fixing lamp holder insulated body with back plate for angle batten fitting fixed with round block complete all as specified and directed
Supply and fix LED energy efficient building security light fitting of capacity of 40 W for fixing incl GI pipe bracket 40 mm dia light grade on wall with all fixing arrangement complete all as specified and directed by Engineer-in-Charge.
S& F Exhaust fan metal body, 300 mm sweep, single phase, 50 Hz, heavy duty , with louver and connecting up with and including provision of PVC insulated copper flexible cord of size 23/0.019, 3 core from ceiling rose to connection of exhaust fan and including material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface complete all as specified. Note: Cost for material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface will be measured and paid in seperate item.
S& F Exhaust fan metal body, 450 mm sweep, single phase, 50 Hz, heavy duty , with louver and connecting up with and including provision of PVC insulated copper flexible cord of size 23/0.019, 3 core from ceiling rose to connection of exhaust fan and including material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge. Note: Cost for material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface will be measured and paid in seperate item.
M&L for making hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface including cement work and painting to the wall matching to the existing complete all as specified and directed.
Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 25 Sqmm , 3.5 core complete all as specified and directed by Engineer-in-Charge. (From Main panel to VTPN DB)
Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid complete all as specified and directed by Engineer-in-Charge.
Supply and lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing from LT pole to MCCB DBs, the medium grade GI tubing of 40 mm dia for XLPE cable protection complete all as specified and as directed
S & in replace of Vertical type MCCB TPN DB 4 way double door suitable for MCCB 100 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed.
Supply and replace MCCB 4P, 415V,16KA, 100 amps suitable for Vertical MCCB DB complete all as specified and directed by Engineer-in-Charge.
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair MCB SPN 40 Amps 240 volts for fixing on MCB DB complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair MCB SP 6 to 40 Amps 240 volts for fixing on MCB DB complete all as specified and directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosure Single pole and earth encolsure with a two pin and earth plug with socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosure Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 40/63 Amps complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement complete all as specified and directed by Engineer-in-Charge. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.)
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-Charge.
M & L Tubes, 'light grade', galvanised, with all fitting; laid in trenches or wall for protection of GI wire complete all as specified and directed by Engineer-in-Charge.
SAI RUPA CONSTRUCTIONS
K LAKSHMAN SINGH AND CO
P VIJAY KUMAR
M/S C MALLIAH & SONS
M/s Bhavani Constructions
harshraj and co
M/S M.N.Reddy
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .