Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.3 CrAccepted-AOC | ₹4.3 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹4.4 Cr+₹6.6 L (1.52%)Rejected-Finance | ₹4.4 Cr+₹6.6 L (1.52%) | 2 | Rejected-Finance Being not L1 |
| 3 | 3₹4.8 Cr+₹50.3 L (11.6%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹4.8 Cr+₹50.3 L (11.6%) | 3 | Rejected-Finance Being not L1 |
| 4 | 4₹4.9 Cr+₹58.0 L (13.4%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹4.9 Cr+₹58.0 L (13.4%) | 4 | Rejected-Finance Being not L1 |
| 5 | 5₹6.6 Cr+₹2.3 Cr (52.3%)Rejected-Finance | ₹6.6 Cr+₹2.3 Cr (52.3%) | 5 | Rejected-Finance Being not L1 |
Tender Value
₹4.4 Cr
EMD Value
₹5.2 L
Closing Date
13 Apr 2022, 6:00 pmClosed
Chief Engineer RnD Secunderabad
Chief Engineer RnD Picket Opp Jubli Bus Station Secunderabad 500003
ADDITION ALTERATION OF EXISTING HANGER Nos 5 6 7 14 15 AT ELSEC CAMPUS OF DLRL HYDERABAD
2022_MES_513181_1
84976
Open Tender
Civil Works
Item Rate
270 days
RCI Hyderabad
Class A
Category a i
9 documents required · 9 mandatory
₹2,000
Yes
GE I RnD RCI Hyderabad
₹5.2 L
Yes
12 May 2022
11 Mar 2022
20 Apr 2022
11 Mar 2022
13 Apr 2022
30 Mar 2022
Amount
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Plain cement concrete (1:2:4) type B2, (using 40mm graded aggregate), 50mm thick as in sub base for floors complete all as specified and directed.
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove with filling bitumen in joints complete as per specifications and direction.
Epoxy flooring, 2mm thick including cleaning of surfaces and applying Primer-shaliprime 2E, screed-shalifloor SL UL 3ES and topping-Shalifloor SL TC 4E etc all as specified and as per manufacture instructions. Make: STP or techno commercially equivalent in FOSROC.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, for laying of pipes / cables / poles etc., in any type of soil and getting out hard / dense soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out hard / dense soil complete all as specified and directed.
Plain cement concrete (1:4:8) type D2, (using 40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
RCC (1:2:4) Nominal mix, type B1 (using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing excavated soil to a distance exc 250 m but n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Non skid ceramic tiles 7 to 8mm thick (square / rectangular) polished, area of each tile exc 0.18 sqm and not exc 0.38 sqm as in floor, laid over and including 15mm thick screed bed in cement mortar (1:4), set and jointed and neat cement slurry and pointed in white or coloured cement to match the surface of floor all as specified and directed.
Non skid ceramic tiles 7 to 8mm thick (square / rectangular) polished, area of each tile exc 0.18 sqm and not exc 0.38 sqm as in skirting laid over and including 10mm thick backing coat in cement mortar (1:4), set and jointed and neat cement slurry and pointed in white or coloured cement to match the surface of floor all as specified and directed.
Plain cement concrete, (1:2:4) type B1 (using 20mm graded aggregate), 25mm thick as in sub base for floors complete all as specified and directed.
Specialised static conductive / dissipative self levelling floor topping with following specifications including taking down / removal of existing damaged conductive flooring including screed acid etching soap water cleaning to remove oil grease and other contaminations and grinding the floor surface to remove the surface and undulations as under:- (a) Cleaning of the surface by grinding / scarifying as per manufacturer's instructions. (b) Providing and applying one coat of epoxy primer with nitoprime 25 of M/s FOSROC or Techno commercial eqivalent product in M/s BASE / CIPY (c) Application of 3mm thick epoxy screed with nitofloor eu5 of M/S FOSROC or Techno commerical equivalent product in M/s BASE / CIPY (d) Providing and fixing copper strip of 100 micron thick and 25mm wide on both sides of floor average length 1.5 m in each grid (1.5 x 1.5 = 2.5 Sqm each). Note: The self adhesive copper tape shall struck at the peripheries of the floor and joitned to the ground. All concrete slabs are electrically connected across the expansion and control joints by fixing copper tape. (e) Providing and applying static conductive / dissipative self levelling base coat treatment. Sl conductive under coat shall be of M/s FOSROC or Techno commercial eqivalent of product in M/s BASE / CIPY (f) Providing and applying static conductive / dissipative self levelling top coat 2mm thick. Sl conductive top coat shall be of M/s FOSROC or Techno commercial eqivalent product in M/s BASE / CIPY.
RCC (1:2:4) Nominal mix, type B1 (using20mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers and similar work, rough finished surfaces of finished concrete, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc, rough finished surfaces of finished concrete complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping etc binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plate conforming to Fe-410-W(Gde E-250) quality B complete all as specified and directed.
Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attach, conforming to Fe-410-W (Gde E-250) quality B complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brick work with fly ash bricks, straight or curved on plan exc 6m mean radious built in CM (1:6) complete all as specified and directed.
Plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in copings, door / window cills etc., including necessary form work, complete all as specified and directed.
Rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surface finished the surface fair and even complete all as specified and directed.
Aluminium powder coated door frame of size 101.60 x 44.45 x 3.18mm of approved manufacture fixed to floor, wall with rawal plug and screws and fixing door shutter with frame of anodized aluminium powder coated (including mortice lock, door handle, tower bolt, hinges and tinted transperent coloured glass pane not less than 5.5 mm thick fixed with rubber gasket and aluminium beading / glazing clips size 19.00 x 17.30 x 0.70mm (Weight 0.097 Kg/RM of both side) shutters with Top lock rail and vertical member of size 83.50x44.45.x 2.30mm and bottom member of size 114.30 x 44.45 x 2.30mm of approved make complete all as specified and directed.
Factory made UPVC window / ventilators of profile width 56mm to 62mm limit thermal conductivity 1.3 kcal/Sqm per hr centigrade, sound insulation up to 40 Dbs, density 1.46 gm/ml, tensile strength 43.90 N/mm2, % of elongation at break 215, tensile modulas 2840 N/mm2 flextural 515 N/sqmm heat aging 15oC no surface defects, thickness 2mm, flextural modular elasticity 2200/sqmm, double gasket and wool pile on window, multipoint gear locking at difference side of frame, antilift device on slide windows with tamper proof screws as per manufacture instructions, complete all as specified and directed.
Aluminium powder coated window frame of size 114.00 x 44.50 x 3.18 mm or neceaary section of approved manufacture BIS fixed to floor / wall with rawal plug and screws and fixing openable / sliding double / tri window shutter with anodized aluminium powder coated window frame (including handle, tower bolt, hinges and tinted transperent coloured glass pane not less than 5.5 mm thick fixed with rubber gasket also fibre or MS galvanised wire mesh and aluminium beading / glazing clip size 19.00 x 17.30 x 0.70mm (wt 0.097 Kg/RM of both side) shutters with Top rail bottom rail and vertical member of size 75.00x44.45x1.50mm of approved make along with Decogrill design size DG-202 complete all as specified and directed by Engineer-in-Charge.
Mild steel Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete all as specified and directed.
Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Preparation of new decorated plastered surfaces of any description and applying two coat of distempering with distemper oil emulsion white or tinted on walls and priming with chalk whiting, and applied over two coat BIRLA / JK water proof wall care putty on plastered surfaces, preparatory to distempering, complete all as directed by Engineer-in-Charge.
Preparation of new steel and iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed.
Preparation on new surfaces of steel surfaces of any description not exceeding 10cm width or girth and and applying two coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed.
Vertical type venetion blinds of approved colour using 100mm wide fabric blinds including operation chords, threads, counter nut, connection chain, necessary fittings complete all as specified and directed. Make: VISTA LEVOLOR / AEROLUX / MAC
Anodised aluminium snap grid frame work for false ceiling providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions including Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
Dismantling and removing of old tarfelt from roof surfaces etc complete all as specified and directed.
Demolition cement concrete (un reinforced) as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type B1 as required complete all as specified and directed.
APP based polymeric membrane minimum weighing 3.5 KG/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt not less than 160 gms/Sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @0.3 Ltr/Sqm by forced all as specified and as directed. Four course roof treatment consist of as under :- (i) M&L for 10mm thick cement plaster in CM (1:4) mixed with water proofing compound as per manufacturer instructions(after applying cement slurry @ 1.2 Kg/Sqm over the existing roof slab) and surface finished even and smooth. (ii) Applying one coat of bituminious primer conforming to IS - 3384 @ 0.3 Ltr per sqm (iii) Laying of APP based membrane as specified thickness and weight (iv) M&L cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3) or cement concrete (1:2:4) type B1 as required. (v) Applying one coat of bitumen grade 85/25 @1.2 kg/Sqm (vi) M&L for cement concrete tiles 25cm x 25xm x 22mm thick, machine pressed; set, jointed and poin ted in net cement shurry in floors, and cut and polished with grey cement and no pigment and including 15mm screed bed in CM (1:4).
APP based polymeric membrane minimum weighing 3.5 KG/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt not less than 160 gms/Sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @0.3 Ltr/Sqm by forced all as specified and as directed. Four course roof treatment consist of as under:- (i) M&L for 10mm thick cement plaster in CM (1:4) mixed with water proofing compound as per manufacturer instructions(after applying cement slurry @ 1.2 Kg/Sqm over the existing roof slab) and surface finished even and smooth. (ii) Applying one coat of bituminious primer conforming to IS - 3384 @ 0.3 Ltr per sqm. (iii) Laying of APP based membrane as specified thickness and weight. (iv) Applying one coat of bitumen grade 85/25 @1.2 kg/Sqm.
Providing cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges or as in roof padding and the concrete surfaces is to be finished even and smooth without using extra cement mixed with water proofing compound (@ 3 % by weight of cement or as per manufacture's instructions). Note: Water proofing compound to be measured and paid separately as "Supply only".
Supply only liquid water proofing compound. Make: Pidilite / Sika / Fosroc / STP.
Taking down old steel rolling shutters of opening size 4.00mm x 5.00m, with out ball bearing, incluidng top cover, anchoring rod, hasp and staple complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Rendering 15 mm thick, in CM (1:6) on fair faces of brick work or concrete surfaces of walls, finished the surface fair and even complete all as specified and directed.
Rendering 15mm thick in CM (1:4) on fair faces of brick work surfaces of walls, finished even and smooth without using extra or cement, complete all as specified and directed.
Rendering 5mm thick in CM (1:4) on ceilings complete all as specified and directed by Engineer-in-Charge.
Preparation of new decorated plastered surfaces of walls of any description and applying two coats of distemper oil emulision white or tinted and priming with chalk whiting, and applied over two coats BIRLA / JK water proof wall care putty on plastered surfaces, preparatory to distempering, complete all as directed.
Preparation of new decorated plastered surfaces of ceilings and applying two coats of distemper oil emulision white or tinted and priming with chalk whiting, and applied over two coats BIRLA / JK water proof wall care putty on plastered surfaces, preparatory to distempering, complete all as directed.
Preparing new surfaces of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489 : 2004, Alkali & fungal resistanc, dirt resistance exterior paint of required shade (Compay Depot Tinted) with silicaon additives @ 1.43 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 Sqm over new surfaces, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as specified and directed.
Non skid ceramic 7 to 8 mm thick coloured tiles (square / rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with pigment as in floor including laying of 20 mm thick screed bed in cement mortar complete all as specified and directed.
Glazed coloured ceramic rectified tiles of size 450 x 300 x 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with pigment as in vertical surface including 15 mm thick backing in cement mortar (1:4) complete all as specified and directed. Make: Johnson or equivalent.
Dismantling of wall and ceiling board (fibre, pulp insulation etc) for insulation board / slab / blankets any thickness incl cover fillet complete all as specified and directed.
Taking down chowkats or frames without taking off shutters from the frames area exc 1.5 sq.m but n exc 4 sq. m each complete all as specified and directed.
Taking down chowkats or frames without taking off shutters from the frames area not exc 1.5 sq. m each complete all as specified and directed.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete as specified, size of frame 105x60mm complete all as specified and directed.
35mm thick, IInd class hard wood plain, framed, panelled factory made shutters (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Mild steel, plain, black sheet, 1.40mm thick as in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood orsteel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
Steel rolling shutters, 1.25mm thickness of laths, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one coat of primer; erected in position as indicated, complete but gear operated type with chain wheel and hand chain including motorised automatic system all as specified and directed by manufacturers instruction including power point, MCCB, wiring etc., complete assessories etc, opening size (size 4.00 x 5.00 m) complete all as specified and directed.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
Factory made solid PVC moulded door shutter 28 to 30 mm thick (style) with 2, 4 or 6 raised panel with 2 mm thick moulded prelam PVC sheet on the front face and 2 mm plain colour PVC sheet on back face supplying and fixing in the frame at site as per specification.
Aluminium anodised sliding door bolt with hasp and stapple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolt and sliding bolt of 300 mm long complete all as specified and directed.
Aluminium anodised sliding door bolt with hasp and stapple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolt and sliding bolt of 250 mm long complete all as specified and directed.
Aluminium anodised, barrel tower bolts, 200mm long of extruded section and fixed, complete all as specified and directed.
Aluminium anodised, barrel tower bolts, 150mm long of extruded section and fixed, complete all as specified and directed.
Butt hinges, medium weight, cold rolled, mild steel of 100 mm size complete all as specified and directed.
Extruded aluminium alloy handles, fabricated type, anodised 150 size complete all as specified and directed.
Taking down rain water pipe of any dia fixed to wall including all fittings, heads, shoes, bends swan near etc and including cleaning for refixing complete all as specified and directed.
Cast iron rain water socketed pipes of 150mm dia, with cement joints, with ears, complete all as specified and directed.
Cast Iron bends, 150mm dia (any radius) complete all as specified and directed.
Cast Iron shoe, 150mm dia (any radius) complete all as specified and directed.
Dismantling water tanks exc 500 & n.exc 1000 Ltrs capacity, complete all as specified and directed.
Rotational moulded polythylene water storage tanks 1000 Litres capacity (cylindrical vertical with closed top), hosted and fixed in position all as specified in SSR Part-I complete all as specified and directed.
Ball brass valves 20mm bore, high pressure, with polythene float and flynut complete, scewed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Cutting chases in brick walls for concealed water tubing and making good in CM (1:3) cutting n. exc 10 cm girth complete all as specified and directed.
Taking up or down 15 mm dia steel tubing and connections including cleaning for refixing or removal complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connections including cleaning for refixing or removal complete all as specified and directed.
Taking up or down 25 mm dia steel tubing and connections including cleaning for refixing or removal complete all as specified and directed.
Steel water tubing, galvanised 15 mm bore, medium grade with all fittings, fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Steel water tubing, galvanised 20 mm bore, medium grade with all fittings, fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Steel water tubing, galvanised 25 mm bore, medium grade with all fittings, fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Gun metal, globe or gate valve 20mm size, cast copper alloy, with iron wheel head, scewed both ends, scewed for iron pipe or for brass ferrule complete all as specified and directed.
Stop valves 20mm size, cast copper alloy, with crutch or butterfly handle, scewed down, scewed for iron pipe or for brass ferrule complete all as specified and directed.
Vitreous china europian type water closet cascade range coloured including 'P' or 'S' trap all fittings and fixing bulbs and vitrous china clay 10 litres capacity low level flushing cistern including flush pipe bracket with seat cover etc, fixed in repairs complete all as specified and directed.
Chromium plated brass jet spray with one metre PVC tube and fixed in repairs, complete all as specified and directed.
Toilet paper holder, chromium plated, fixed in repairs, complete all as specified and directed.
Vitreous china (coloured), counter top Wash Hand Basin of size as per Cat / Model No. including providing 32mm dia CP waste coupling, CP bottle trap, bracket and making all necessary connections, fixed in repairs, complete all as specified and directed.
Chromium plated brass pillar tap and fixed in repairs, complete all as specified and directed.
Vitreous China coloured Urinal, Half stall type, complete including providing and fixing plugs, bedding urinal against wall in Cement Mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe including making good disturbed surfaces in CM (1:3) including 32mm CP bottle trap, CP connecting pipe and CP urinal spreader etc., fixed in repairs, complete all as specified and directed.
Chromium plated, brass, fancy type, soap dish with chromium plated wall flange and fixed in repairs, complete all as secified and directed.
Glass shelf of size 460mm x 130mm x 6mm thick with brass chromium plated railing in front including necessary chromium plated fixing arrangements and fixed in repairs, all as specified and as directed.
PVC connector pipe, 15 mm bore of length 450 mm with PTMT nuts at both ends and fixed in repairs, complete all as spcified and directed.
PVC waste pipe, 32 mm bore, suitable for WHB / urinal and fixed in repairs, complete all as specified and directed.
Chromium plated brass bib cock with wall flange, fixed to 15mm bore iron pipe and fixed in repairs, complete all as specified and directed.
Chromium plated angular stop cock with wall flange fixed to 15mm bore iron pipe and fixed in repairs, complete all as specified and directed.
Chromium plated, towel rail 600mm long 20mm dia, 'D' type, fixed in repairs, complete all as specified and directed.
Chromium plated health faucet tube with hook (foma Ivory), fixed in repairs, complete all as specified and directed.
Cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4), type B1, diameter of out let pipe 100 mm fixed in repairs, complete all as specified and directed.
Stainless steel round grating 150mm dia complete all as specified and directed, fixed in repairs, complete all as specified and directed.
Aluminium partition (area not exceeding 1.5 Sqm each panel) with frame of size 63mm x 38mm x 2mm thick, fixed with hold fasts including snap beading rubber gasket etc., complete as directed by the Engineer-in-Charge.
Sun control film, 25 micron reflective type, best quality, on glass, fixed in repair, complete all as specified and directed.
Pre-laminated particle board 9mm thick, interior grade, prelaminated both side with decorative choice lamination, fixed with screws timber / aluminium frame work / partition as in repair complete all as specified and directed.
Block boards 18/19mm thick, Grade-2 quality, interior grade, commercial type, screws to timber frame work, fixed in repairs, complete all as specified and directed.
Ply wood 12mm thick, grade BWR, type BB fixed with nails as in cabinet and cup board fixed in repairs, complete all as specified and directed.
Decorative laminate 0.9 mm thick, type-1 (Sunmica) of surfaces finish colour and pattern fixed in repairs with approved adhesive as per makers instructions, complete all as specified and directed.
Second class hard wood Plain fillets square, rectangular or triangular in section clean sawn, secured with nails or brads sectional area exc 13 sqcm & n.exc 25 Sqcm fixed in repairs incl applying two coats of synthetic enamel paint, complete all as specified and directed.
Second class hard wood, best quality, moulding bead bull nosed, splayed, chamfered or rounded on one edge or face fixed with nails sectional area n.exc 3 Sqcm fixed in repairs including two or more coat of french polishn complete all as specified and directed.
Contineous piano hinges brass width of flap 30mm when opened fixed in repairs, complete all as specified and directed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other part made of mild steel heavy duly and fixed repair incl taking down aluminium shutter and refixing in replacement of pivat etc., complete, fixed in repairs all as specified and directed.
Door closer hydraulically regulated designation No. 3 universal type suitable for door shutter of 851 to 1000 mm in width and of weights between 80 Kg and aluminium (Die cast) body, fixed in repairs, complete all as specified and directed.
Complete removal of existing treatment of old decorated surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and applied over two coats of BIRLA / JK water proof wall care putty complete all as specified and directed.
Applying two coats of oil bound distemper to old decorated (distempered) surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
Preparing old plastered surfaces of walls / ceiling and applying two coats of exterior emulsion paint over a coat of primer including removal of existing treatment on wall / ceiling surfaces including cornices, pilasters etc., by scrapping down with wire brushes and removing existing loose finishes, particles etc., complete all as specified and directed.
Preparation of old wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint and complete all as specified and directed.
Preparation of new old wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer and complete all as specified and directed.
Preparation of new or previously untreated steel and iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paints over a coat of red lead complete all as specified and directed.
Applying one coat of synthetic enamel paint to old painted steel surfaces of any description over 10 cm width or girth including preperation of surfaces red oxide zinc chrome primer complete all as specified and directed.
Mild Steel Fabricated Portable Office Cabin of 12’ x 10’ x 9’ with complete Insulation, Plywood Cladding and Electrical Fittings complete all as per manufacturer's instructions. Fabricating Specifications are as under :- (a) Bottom Frame - 140x50mm formed MS G Channel of 3mm thick. (b) Stiffener Bottom - 80x40mm, 25x50mm square pipes. (c) Top frame - Frame made of 50x50mm, square pipes. (d) Stiffener top - 50x50mm, 25x50mm & 25x25mm square pipes. (e) Side wall stiffeners - Corner post shall be of 50x50mm, 25x50mm Square pipes & Wall, thickness of 50mm. (f) Paneling outside - Speciallly corrugated 1.60mm thick sheet welded on MS Frame. (g) Internal wall paneling - The paneling of side walls and roof shall be of 9mm thick Pre laminated particle board (MDF) & all vertically and horizontal corners shall be neatly & smoothly finished with Aluminum sections. (h) Roof outside - 1.6mm thick MS Sheet properly sloped & water tight. (j) Bottom Flooring - On the bottom frame 18mm thick Bison Panel i.e. Cemented bonded fiber sheet shall be fixed on the panel. (100% water, termite & dimensional proof with vinyl Carpet) (k) Aluminum Sliding Windows of size (4'x3' - 02 Nos = Double shutter sliding aluminum powder coated windows with 4mm thick glass for all windows, safety grills from outside & canopy on the top of windows. (l) Main Door size 7'x3' - 01 No = The door shall be of external opening type made out of the same material as wall panels & canopy above the door. Frame work by tubular pipe of 30x30 & the door interior shall be finised with same material matching with that of the cabin interior. Door with std hardware lock & handles.
(m) Insulation - Glass wool density of 32kg/Cum with insulatin for top & 13mm foam on side walls (n) Wiring - All wiring shall be concealed and shall be PVC insulated copper wires of ISI quality, suitable for 240 volt, 50 Hz single phase AC power supply. 2.5mm thick cable for lighting, 5Amp switches with 3 Pin Sockets, bulk head light above the door, 4mm thick cable for main electrical supply & with MCB protection. (o) Electrical Fitting - All electrical fitting in the portable cabin shall be 220-240 V. Tube light - 02 Nos, Bulk head door light - 01 No, Cabin Fan - 01 No, 3 Pin Socket with Switchboard- 02 Nos, A/C Provision - 01 No. (p) Outside Painting - All components are painted with a coat of primer & 2 Coats of corrosion free paint i.e. synthetic epoxy paint. (q) Hooks - Specially formed for easy lift & shift. (r) Detailed specification shall be followed as per OEM specification as approved by GE.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
20mm thick, granite (of any type work) work (table rubbed and polished) in steps, jambs, pillars, window-cills, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Providing, plain cement concrete (1:2:4) type B1 (using 20mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Taking down carefully any type of point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc, and removing (except those to be reused shall be kept in safe custody at the site and making good disturbed surfaces of walls, floors etc, to match with the existing complete all as specified and directed.
Point wiring complete with 1.5 Sqmm PVC insulated unsheathed multi stranded FRLS copper conductor 1100 Volts grade draw through in and including 20mm dia PVC conduit and conduit accessories, concealed in walls including making necessary chases in walls and making good to match with existing surface and terminated to and including provision of modular metal flush boxes (metal switch board of any type and size) with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 Sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 5 Amps, one way modular switch for one light point. Note: The cost of metal flush boxes, modular white cover plate deemed to include under respective items of this Schedule.
All as per item No. 127 here-in-before, but for one fan point controlled by one 5 Amps one way modular switch.
All as per item No. 127 here-in-before, but for one exhaust fan point controlled by one 5 Amps one way modular switch.
All as per item No. 127 here-in-before, but for one 3 pin socket outlet 6 Amps modular socket controlled by one way switch on same board.
All as per item No. 127 here-in-before, but for one 3 pin socket outlet 6 Amps modular socket controlled by one way switch on independent board.
All as per item No. 127 here-in-before, but for 15 Amps socket outlet with 2.5 Sqmm copper including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly.
All as per item No. 127 here-in-before, but with cable 4 Sqmm for phase and neutral & 4 Sqmm for earth continuity. (For AC point wiring and 20 Amps socket)
Modular switch one way 6 Amp, one module 240v, single pole complete all as specified and directed.
Modular switch one way, 16 Amp, one module 240v, single pole complete all as specified and directed.
Modular socket, 6 Amp - 2/3 pin combined 2 module, 240v complete all as specified and directed.
Modular socket, 6/16 Amp -2/3 pin (5 pin) combined 2 module, 240v complete all as specified and directed.
Ceiling rose two to three terminal surface backlite type AC 50Hz 230 volts complete all as specified and directed.
LED surface mounting ultra modern designed aesthetically LED luminaire of 15 Watts, 230 Volts, 50 Hz, 1 x 1, which provides soft-light and glare free symmetrical illumination suitable for surface mounting complete all as specified and directed.
LED recess mounting 34 Watt, 2 x 2 luminaire suitable to operate on 230 volts, 50 Hz single phase AC supply complete all as specified and directed.
LED tube light fitting, 20 W, 230 V, regal batten type, single side connection included with 20 Watt LED tube rod single side connection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
LED high bay 150 W light fitting at any height in hangers / workshop with aluminum alloy pressure dia casted housing and control gear box with toughened glass and individual high power LEDs with secondary optics IP-65 protection and impact resistance of IK-07, integral electronic driver prewired upto terminal block with driver complete with all accessories complete all as specified and directed. Note: Rate includes scaffolding / ladder / tools etc, to fix high bay light at any height.
LED flood light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP-66 protection made of impact resistance with 10KV built surge protection device of capacity 120 W complete in replacement of conventional fitting of any type complete all as specified and directed.
Modular fan step regulator, 120 watts, 2 module, 230 volts complete all as specified and directed.
CRCA sheet metal enclosure with metal clad plug and socket single phase with five pin and earth plug & socket suitable for surface / flush mounting 240 V, 20/32 Amps capacity controlled by and including one 20/32 Amps MCB SP, 10 KA capacity complete all as specified and directed.
Single pole and neutral sheet metal enclosure 8 way double door for MCB's, phosphatised powder painted with bus bar 200 Amp rated 240 volt AC complete all as specified and directed.
Sheet metal enclosure for prewired distributed board double door, powder coated VTPN, 4 way without MCCB, three phase 415 volt with 100 Amps rated tinned electrolytic copper bus bar with neutral link complete all as specified and directed.
MCCB TP 100 Amps capacity 16 KA, 415 volts, 50 Hz complete all as specified and directed.
MCB single pole and neutral 40 Amps capacity 10 KA, 240 volts, 50 Hz complete all as specified and directed.
MCB single pole (SP) 10 kA of 6 Amps to 32 Amps capacity 240 volts, 50 Hz, 'C' curve complete all as specified and directed.
CRCA sheet metal enclosure with metal clad plug and socket three phase with five pin and earth plug & socket suitable for surface / flush mounting 415 V, 63 Amps capacity controlled by and including one 63 Amps MCB TPN, 10 KA capacity complete all as specified and directed.
Sub main wiring complete with 2 runs of 6 sqmm PVC insulated and unsheathed 1100 V grade FRLS multistranded copper conductor and drawn through in and including PVC conduit of medium grade and conduit accessories of suitable size concealed in walls with, necessary civil works for making good disturbed surface, and / or laid on surfaces over ceilings / columns etc and connecting terminal ends to DBs and DB's including of 1 run of 6 Sqmm insulated multistranded FRLS copper cable as earth continuity conductor and connecting to common earth dolly including taking down old one complete all as specified and directed. Note: Two runs of 6 Sqmm copper conductor, one run of 6 Sqmm copper earth continuity conductor and one run of suitable size of PVC rigid conduit and required conduit accessories shall be measured as one unit length.
Sub main wiring complete with 2 runs of 2.5 sqmm PVC insulated and unsheathed 1100 V grade FRLS multistranded copper conductor and drawn through in and including PVC conduit of medium grade and conduit accessories of suitable size concealed in walls with, necessary civil works for making good disturbed surface, and / or laid on surfaces over ceilings / columns etc and connecting terminal ends to DBs and DB's including of 1 run of 2.5 Sqmm insulated multistranded FRLS copper cable as earth continuity conductor and connecting to common earth dolly including taking down old one complete all as specified and directed. Note: Two runs of 2.5 Sqmm copper conductor, one run of 2.5 Sqmm copper earth continuity conductor and one run of suitable size of PVC rigid conduit and required conduit accessories shall be measured as one unit length.
Sub main wiring complete with 4 runs of 6 sqmm PVC insulated and unsheathed 1100 V grade FRLS multistranded copper conductor and drawn through in and including PVC conduit of medium grade and conduit accessories of suitable size concealed in walls with, necessary civil works for making good disturbed surface, and / or laid on surfaces over ceilings / columns etc and connecting terminal ends to DBs and DB's including of 2 runs of 6 Sqmm insulated multistranded FRLS copper cable as earth continuity conductor and connecting to common earth dolly including taking down old one complete all as specified and directed. Note: Four runs of 6 Sqmm copper conductor, two runs of 6 Sqmm copper earth continuity conductor and one run of suitable size of PVC rigid conduit and required conduit accessories shall be measured as one unit length.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level connected to galvanized earth lead wire 4mm dia, by means of galvanized iron or steel bolts, nuts, check nuts and washers and connected to equipment as directed, including funnel with GI medium grade watering pipe 20 mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode with concrete pit in PCC (1:3:6) type C1, 50mm thick precast RCC (1:2:4) type B1 cover slab reinforced with 8mm dia deformed bar 15cm c/c and suitable handle of 10mm dia round bar, 20mm bore, light grade GI pipe for earth lead protection including necessary excavation earth work in soft / loose soil and disposal of soil distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No. 3 (of SSR Part-I) including taking up of old GI earth plate complete all as specified and directed. Note: (i) Cost of GI earth lead upto 7.50 RM is deemed to be included in the quoted rate. (ii) Rate deemed to be included cost of excavation in any type of strata, RFR and removal upto 50m, PCC chamber, funnel and RCC cover plate.
Earthing complete with galvanised copper earth plate electrode 600 x 600 x 3mm, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level connected to copper earth lead 20x3mm strip, by means of brass bolts, nuts, check nuts and washers and connected to equipment as directed, including funnel with GI medium grade watering pipe 20mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode with concrete pit in PCC (1:3:6) type C1, 50mm thick precast RCC (1:2:4) type B1 cover slab reinforced with 8mm dia deformed bar 15cm c/c and suitable handle of 10mm dia round bar, 40mm light grade GI pipe for earth lead protection including necessary excavation earth work in soft / loose soil and disposal of soil distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No. 3 (of SSR Part-I) including taking up of old GI earth plate complete all as specified and directed. Note: (i) Cost of copper earth lead upto 7.50 RM is deemed to be included in the quoted rate. (ii) Rate deemed to be included cost of excavation in any type of strata, RFR and removal upto 50m, PCC chamber, funnel and RCC cover plate.
Earth continuity conductor with 20 x 3mm copper strip fixed to wall on batten or recess or chases with necessary porocelen insulators or buried in ground or drawn in conduit / pipe / wall or fixed to poles or any other indicated situation for loop earthing etc including taking down old conductor of any size complete all as specified and directed.
Modular telephone RJ 11 socket, 1 module, including connected items for fixing in flush box complete all as specified and directed.
Modular LAN RJ 45 socket, 1 module, including connected items for fixing in flush box complete all as specified and directed.
PVC conduit 32mm dia and conduit accessories, concealed in walls and terminated to and including provision of modular metal flush boxes with modular metal frame plate and white cover for sockets complete all as specified and directed.
Supply, install, test and commissioning split type air conditioning unit (inverter type) 5 star complete with driver motor air cooled condenser with all accessories varied speed and dual rotary compressor including fixing the outdoor units as per manufacture recommendation and fixing of room (high wall) unit on wall providing and making interconnection including refrigerant piping with nitryle rubber insulation and control cable from indoor to outdoor upto a distance of 3.00 m power cabling (Max 3.00 m from isolator / encloser) to unit, first recharging of refrigerant gas including cordless remote, drain pipe of 25mm dia for connecting drain line from indoor unit to maximum of 3.00 m to nearest drain point complete as required capacity of 2 TR complete all as specified and directed by Engineer-in-Charge.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
Ceiling fan complete with electronic type regulator and accessories 230 V, 1200 mm sweep BEE 5 star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Air Circulator fans 230 volts single phase oscillating 600 mm sweep non capacitor type suitable for wall mounting complete all as specified and directed.
Taking down split / window AC 1.5 Ton / 2 Ton capacity of and keep in safe custody, replacement copper tubing suction and liquid line from indoor to outdoor unit and refixing the same in service condition and top up / gas charging with refrigerant gas (R-22) after vaccuming & leak testing including brazing suction / discharge line and testing including necessary electrical connection complete all as specified and directed.
Supply, installation, commissioning of water cooler partially stainless steel, electric driven single phase having approx storage of 80 ltr and nominal cooling capacity 40 litre per hour complete all as specified and directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed.
Taking down and dismantling old unserviceable rusted strips including connected items from buildings, walls and roofs complete all as specified and directed.
Aluminum strip 25 x 3mm complete with saddles and fixing screws for roof / down conductor on porcelain / epoxy spacer insulator or fixed in GI Pipe complete all as specified and directed. Note: Rates quoted by the contractor are deemed to be included for cutting, jointing pieces of strip with nut bolt.
Refixing aluminum strip 25 x 3mm complete with saddles and fixing screws for roof / down conductor on procelain / epoxy spacer insulator fixed on wall / roof at any height complete all as specified and directed. Note: Rates quoted by the contractor are deemed to be included for cutting, jointing pieces of strip with nut & bolts.
Porcelain / epoxy white / brown / green spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding / fixing roof conductor / down conductor of lightning conductor complete all as specified and directed.
GI light grade pipe of 20mm dia for fixing air termination rod and earth strip on roof including dismantling of old worn out GI pipe, complete all as specified and directed.
Single pointed air termination aluminium rod 12mm dia 300mm long with fixing arrangement including dismantling of old unserviceable / deshaped conductor and removed from site of work, fixed in repairs, complete all as specified and directed.
Test Point Terminal Block made of gum metal or phophorus bronze size (75 x 75 x 25) mm drilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw, fixed in repairs, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5m below ground level connected to GI strip 25 x 4mm as earth lead by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion, complete all as specified and directed. Note: (i) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, 50mm thick RCC (1:2:4) type B1 (using 20mm graded stone aggregate) cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. (ii) GI earth strip beyond 7.5m will be measured and paid separately.
Taking up the unserviceable XLPE, LT UG cable 3.5 / 4 core 1 Sqmm to 185 Sqmm from trenches or from walls complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning 1100 volts grade, 185 Sqmm, 3.5 core, LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanised steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches / passing through pipe / duct / road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc, complete all as specified and directed. Note: Earthwork excavation, sand cushioning GI pipe and cable protection will be measured and paid separately.
All as per item No. 177 here-in-before, but 3.5 core, 120 Sqmm.
All as per item No. 177 here-in-before, but 3.5 core, 25 Sqmm.
Supply and spreading natural river sand of approved quality for cushioning of cable laid in trenches including compacting and leveling complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class LV type 1, size 250mm x 150mm x 40mm, laid flat adjacent to each other, perpendicular to cable in trenches for protection of cable complete all as specified and directed.
Cutting of existing bituminous / PCC road or flooring / plinth protection, for laying of GI pipe in road intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC (1:2:4) type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as specified and directed.
GI pipe, 100mm dia, light grade fixed to walls or laid in trenches etc., for protection of UG cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls complete all as specified and directed.
Supply, fixing, testing & commissioning of CPRI approved LT panel board made out of CRCA sheet 2.0mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switch gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switch gear, and the nuts / bolts etc used are to be made of rust proof material including as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V including suitable capacity of bus bar complete with powder coating, necessary internal electric connection as required and provision of the following: - (a) 1000A capacity of aluminium bus bar, TPN full for phase and neutral with colour code PVC sleeves - 01 Job. Incoming: (b) MCCB 630 Amps, 4 Pole, 415 volts, 50 Hz, 50 kA - 01. Outgoing: (c) 63 MCCB Amps, electric, 4 Pole, 415 volts, 50 Hz, 16 kA - 12 Nos. (d) LED RYB indicating lamps - 01 set. (e) LED ammeter and voltmeter with necessary CTs and display of requried rating. (f) Panel wiring with PVC insulated unsheathed single core, 1100 volts grade cable with copper conductor, multistranded of suitable size - 01 Job. (g) Inter connection of bus bar with MCCB, connector with suitable size aluminium strip - 01 Job. (h) Provisioning of cable glands and cable lugs for all incoming and outgoing cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion - 01 Job.
Supply, fixing, testing & commissioning of CPRI approved LT panel board made out of CRCA sheet 2.0mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switch gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switch gear, and the nuts / bolts etc used are to be made of rust proof material including as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V including suitable capacity of bus bar complete with powder coating, necessary internal electric connection as required and provision of the following: - (a) 630A capacity of aluminium bus bar, TPN full for phase and neutral with colour code PVC sleeves - 01 Job. Incoming: (b) MCCB 400 Amps, 4 Pole, 415 volts, 50 Hz, 50 kA - 01. Outgoing: (c) 63 MCCB Amps, electric, 4 Pole, 415 volts, 50 Hz, 16 kA - 08 Nos. (d) LED RYB indicating lamps - 01 set. (e) LED ammeter and voltmeter with necessary CTs and display of requried rating. (f) Panel wiring with PVC insulated unsheathed single core, 1100 volts grade cable with copper conductor, multistranded of suitable size - 01 Job. (g) Inter connection of bus bar with MCCB, connector with suitable size aluminium strip - 01 Job. (h) Provisioning of cable glands and cable lugs for all incoming and outgoing cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion - 01 Job.
Electrically operated analogue time switches 24 programmable every 15 minute, with backup of 100 hours, current capacity 16A, with 1 change over (CO), for street light suitable to operate on 230 Volts, fixed in repairs, complete all as specified and directed. Make: Indoasian CAT No. TL016AB0 and TDA43110 or equivalent in Legrand / Siemens / Schneider.
Taking up or down 25mm bore steel tubing along with connections and all fittings from trenches / walls / floors complete all as specified and directed.
All as per item No. 187 here-in-before, but 50mm bore of pipe.
Steel water tubing 50mm bore, medium grade, ISI marked, galvanized, including all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., laid in trenches or fixed to walls and ceilings or concealed in walls, ducts / ceilings or laid in floors complete all as specified and directed.
All as per item No. 189 here-in-before, but 25 mm bore of pipe.
Cutting GI pipe of any size and reducing to required length before laying and insertion of 'T' of 50 x 50 x 50mm and branches for 50 mm complete all as specified and directed.
Cutting of existing flooring / road / plinth protection for laying of LT UG cables pipe and making good disturbed surface with PCC (1:2:4) type B1 complete all as specified and directed.
Masonry valve chamber of size 750 x 750 x 750mm for 80 mm dia gate valve including excavation and earth work in any type of soil and 100 mm thick PCC (1:4:8) type D2 foundation, brick work in CM (1:6), plastering internal surface 15 mm tick in CM (1:4), PCC (1:3:6) type C1 coping, 50 x 50 x 6 mm angle iron 6 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
Gun metal gate valves, 25mm cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and directed.
INDGUARD ENGINEERS
M/s. P S REDDY
STANDARD AGENCIES
DANDU CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .