Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAdmitted-Finance | ₹12.6 L | L1 | Admitted-Finance |
| 2 | L2₹13.8 L+₹1.2 L (9.60%)Admitted-Finance | ₹13.8 L+₹1.2 L (9.60%) | L2 | Admitted-Finance |
| 3 | L3₹17.0 L+₹4.4 L (35.1%)Admitted-Finance | ₹17.0 L+₹4.4 L (35.1%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NANDHAGOPAL ELECTRICAL CONTRACTOR L1 | V M ENTERPRISES L2 | S BAVA ENGINEERING L3 |
|---|---|---|---|---|---|---|
| 1.00 | Removal of complete light fitting from the ceiling for rewiring, testing, painting and refixing to the original position etc.(2x40w and 2x65W) at Radioactive areas and above 5 mtr areas | 20 | nos | 900 ₹18,000 Lowest | 970 ₹19,400 | 1,000 ₹20,000 |
| 1.01 | Removal of complete light fitting from the ceiling/wall below 5 Mtr for rewiring, testing, painting and refixing to the original position etc.(2x40w and 2x65W) at normal area | 15 | nos | 800 ₹12,000 | 750 ₹11,250 Lowest | 750 ₹11,250 Lowest |
| 1.02 | Removal of old (2x40W / 2x65W) light fitting from the ceiling/wall below 5 Mtr and fixing on new 2 X 28W FTL or 30W/45W/ LED luminaries to the original position etc.at normal areas | 15 | nos | 700 ₹10,500 | 620 ₹9,300 Lowest | 650 ₹9,750 |
| 2.00 | Replacement of following fluorescent/CFL/Incandescent light fitting accessories, including attending of loose connection etc. | 1 | NA | - | - | - |
| 2.01 | Fluorescent tube light | 400 | nos | 50 ₹20,000 Lowest | 60 ₹24,000 | 80 ₹32,000 |
| 2.02 | Fluorescent tube light starter | 300 | nos | 50 ₹15,000 | 28 ₹8,400 Lowest | 70 ₹21,000 |
| 2.03 | Choke 40/65W | 175 | nos | 60 ₹10,500 Lowest | 70 ₹12,250 | 80 ₹14,000 |
| 2.04 | Tube light holder/bracket single or double, starter | 100 | nos | 70 ₹7,000 Lowest | 80 ₹8,000 | 80 ₹8,000 |
| 2.05 | Incandescent lamp/CFL | 30 | nos | 50 ₹1,500 | 38 ₹1,140 Lowest | 60 ₹1,800 |
| 3.00 | Replacement of following accessories in 250/400 watts MV lamp/ballast/ capacitors/lamp holder etc in the light fittings at highbay area of Labs. | 3 | nos | 1,200 ₹3,600 | 850 ₹2,550 Lowest | 2,000 ₹6,000 |
Tender Value
₹14.0 L
EMD Value
₹28,078
Closing Date
3 Sept 2025, 3:00 pmClosed
Superintending Engineer, MMG Director, MMG
Director, IGCAR, HB Building, IGCAR, Kalpakkam - 603102.
Annual maintenance of Electrical systems and equipments in PIED and associated buildings in IGCAR for the year 2025-26.
2025_IGCAR_872452_1
IGC/TS/AMC/2025/15761
Open Tender
Electrical Works
Works
365 days
RML Building
--
2 documents required · 2 mandatory
₹0
₹28,078
1 Oct 2025
11 Aug 2025
4 Sept 2025
12 Aug 2025
3 Sept 2025
12 Aug 2025
12 Aug 2025 - 19 Aug 2025
Amount
Removal of complete light fitting from the ceiling for rewiring, testing, painting and refixing to the original position etc.(2x40w and 2x65W) at Radioactive areas and above 5 mtr areas
Removal of complete light fitting from the ceiling/wall below 5 Mtr for rewiring, testing, painting and refixing to the original position etc.(2x40w and 2x65W) at normal area
Removal of old (2x40W / 2x65W) light fitting from the ceiling/wall below 5 Mtr and fixing on new 2 X 28W FTL or 30W/45W/ LED luminaries to the original position etc.at normal areas
Replacement of following fluorescent/CFL/Incandescent light fitting accessories, including attending of loose connection etc.
Fluorescent tube light
Fluorescent tube light starter
Choke 40/65W
Tube light holder/bracket single or double, starter
Incandescent lamp/CFL
Replacement of following accessories in 250/400 watts MV lamp/ballast/ capacitors/lamp holder etc in the light fittings at highbay area of Labs.
Replacement /New flush/concealed type switches & sockets, MCBs upto 4Nos.of 5/15 amps in the MS boxes in various locations of the lab.
Rectification of faults such as earth fault, loose connections, changing of defective wires, components etc in Post top lantern, light fittings in & around RML
Preventive maintenance of Air conditioning power supply switch boxes in various locations including MCBs/ Industrial switches & sockets/ELCBs etc.and functional test of the same as directed by the Engineer-in-charge.
Replacement/repair of faulty Public addressing system speakers and telephone line points in concealed/conduit type and in MS boxes in various locations of the lab.
General Cleaning of Main panels, PCCs, MCCs, & HT panel surfaces and rubber mats as per the scope of work.
General Cleaning of Transformers/DG sets/Telephone Exchange MDF panel,UPS,Power supply,PA Amplifiers etc.
Intra movement of various electrical items, components and equipments in different electrical stores in RML complex and buildings and sort out of electrical items in stores on day to day basis for various works
Maintenance of Power and Lighting Distribution Boards located in various buildings/Laboratories as per the scope of work and as directed by the Engineer-in-charge.
4/6 Way 16/32/63 Amps. Distribution Boards
8 Way 16/32/63 Amps. Distribution Boards
12 Way 16/32/63 Amps. Distribution Boards
Cleaning of battery surfaces, filling of distilled water and recording the values monthly as directed by the Engineer-in-charge.
Installation of 19mm/25mm PVC Trunking (Casing & capping) as per the scope of work and directed by the Engineer-in charge.
Collection/disposal of electrica l/other consumable and spares from/to central stores as directed bythe Engineer- in charge.
Monitoring and recording the LT/HT panel reading and Transformer temperature as directed by the Engineer in- charge.
Breakdown maintenance of MCC and plant equipments etc.
Retermination of power cable at motor and starter side 6-35 sq.mm
Retermination of power cable at motor and starter side 35-95 sq.mm
Preventive maintenance of Electrical panel as per scope of works
Main panel consists of 2 incomer ACBs, outgoing of 17 Nos. TPN, ACBs Switches, etc.
Mains distribution panels consists of 1/2 incomer,13 to 20 outgoings
Mains distribution panels consists of 1/2 incomer, 6 to 12 outgoing
Mains distribution panels consists of 1 incomer, 1 to 5 outgoing
Hot cell control desk, lighting/power circuits, MSM power circuits.
Individual starter compartment upto 10 HP motor
Individual starter compartment above 11 HP to 40 HP motor
Individual starter compartment above 41 HP to 100 HP motor
Incell crane panel, Power Manipulator panel , VTS panel
Battery operated vehicles
Main panel consists of 1 incomer breaker and 2 Nos.of outgoing breakers in RHS substation
Ph-I plant room RCP1 & 2 and cell door drive control panel for hot cell
Functional test of wall mount Emergency lamps at various locations monthly once as directed by the Engineer-in-charge
Laying of 3 or 4 core 2.5/4/6/10 Sq.mm armoured/ unarmoured cables in inbuilt trench / wall area/trays& PVC/ XLPE armoured cables in hume pipe/built-in -trenches/on the walls/trays as per the scope of work and as directed by the Engineer-in-charge.
End termination of 3 or 4 core 2.5/4/6/10 Sq.mm copper/ aluminum control/power armoured cables
Fixing of various size of new exhaust fans at different locations in RML complex by replaceing the existing one with proper clamp/coach screw as directed by Engnieer-in-charge.
Painting of Electrical panels/eqpts/machineries/ accessories/ chequer plates including supply of all as per the scope of work.
Overhauling and Preventive maintenance of various capacity motors as per scope of work
Ceiling fans/Pedestal fans/Exhaust fans of rating upto 100 W
Ceiling fans/Pedestal fans/Exhaust fans of rating upto 400 W
Air monitor vacuum pump motor 1 Ph rating upto 2.HP
Motors of capacity upto 3.0 HP to 5.0 HP
Motors of capacity upto 6.0 HP to 10.0 HP
Rewinding and maintenance of various capacity motors as per scope of work
Ceiling fans/Pedestal fans/Exhaust fans of rating upto 100 W
Ceiling fans/Pedestal fans/Exhaust fans of rating upto 400 W
Air monitor vacuum pump motor 1 Ph rating upto 2.HP
Motors of capacity 7.5 HP
Motors of capacity 10 HP
Wiring with new copper conductor wire of 2X1.5/2.5/4 Sq.mm PVC insulated wires and bare copper for earth as per the scope of work
Laying of new MS/GI conduit /flexible conduit pipe and wiring in the office areas and plant areas as per the scope of work and as directed by the Engineer-in-charge.
Installation,testing and commissioning of reputed make LED fittings at RML complex and other areas as directed by Engineer-in-Charge
Supply,Installaion,tetsing & Commissioning of reputed/ branded 30 W indoor type LED square surface down lights with mid power LEDs as light source & exclusively designed Extruded Aluminium frame with powder coating along with electronic driver at RML indoor premises and annex building area etc. as directed by the Engineer-in-Charge.
Supply,Installaion,tetsing & Commissioning of reputed/ branded 38/45 W indoor type LED square surface/recessed down lights with mid power LEDs as light source & exclusively designed Extruded Aluminium frame with powder coating along with electronic driver at RML indoor premises and annex building area etc. as directed by the Engineer-in-Charge.
Supply,Installaion,tetsing & Commissioning of reputed/ branded 45 W indoor type LED rectangle surface/recessed down lights with mid power LEDs as light source & exclusively designed Extruded Aluminium frame with powder coating along with electronic driver at RML indoor premises and annex building area etc. as directed by the Engineer-in-Charge.
V M ENTERPRISES (BID ID -3272267)
S BAVA ENGINEERING (BID ID -3272389)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .