Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.7 LAccepted-AOC | 1 | Accepted-AOC Lowest tenderer | |
| 2 | 2₹11.3 L+₹97,265.30 (9.38%)Rejected-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | 2 | Rejected-AOC 2nd | |
| 3 | 3₹11.7 L+₹1.3 L (12.9%)Rejected-AOC | 3 | Rejected-AOC 3rd | |
| 4 | 4₹12.3 L+₹2.0 L (19.1%)Rejected-AOC | 4 | Rejected-AOC 4th |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
12 Oct 2020, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
Repair/maint to internal wiring including MCBs and fitting/fixtures at Vayusenabad under GE (AF) Tughlakabad
2020_MES_373017_1
CA No-GE/TKD/TOKEN-35/2020-21
Open Tender
Civil Works - Others
Item Rate
330 days
GE AF TUGHLAKABAD
MES contractor enlisted as Class E or above category bi having deposited Standing Security of Rs. 50000 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹40,000
Yes
23 Nov 2020
28 Aug 2020
14 Oct 2020
25 Sept 2020
12 Oct 2020
25 Sept 2020
29 Aug 2020 - 25 Sept 2020
Amount
Taking out old unserviceable point wiring complete with fitting/fixtures and M&L for point wiring concealed conduit type complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and include PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 Sqmm as earth wire, connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular flush plate all as specified and as directed by Engr-in-charge. Note: The work includes cutting of chases and making good to match with surrounding necessary periodical applied one coat of putty and one coat of oil bound distemper to be included in quoted rate.
One Light point controlled by one way switch.
One Fan point controlled by one way switch and fan regulator on same switch board.
One 3 pin socket outlet point 5 Amp on same board.
One 3 pin socket outlet point 5 Amps on independent board.
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 Sqmm size.
One 3 pin socket out let 15 Amps power point on independent board, with cables 4 Sqmm size and earth wire 4 Sqmm.
One light point controlled by two way switche with cable of size 2.5 Sqmm nominal area and 2.5 Sqmm earth wire.
Taking out old unserviceable sub main wiring of any size and type and M&L for sub main wiring with multistranded FRLS copper conductor cable PVC sheathed in and including concealed in brick wall/RCC as per the site condition providing suitable PVC conduit with 2 runs of 6 Sqmm and 1 run of 6 Sqmm FRLS copper conductor as earth wire and connected to earth dolly complete all as specified and as directed by Engr-in-Charge. Note: (i) The work includes cutting of Chassis and making good to match with surrounding necessary periodical applied one coat of putty and one coat of oil bound distemper to be included in quoted rate. (ii) One unit run include 3 runs of 6 Sqmm wire, conduit shall be measured as one unit.
Taking out old unserviceable Three Phase submain wiring of any size and type and M&L for sub main wiring with multistranded FRLS copper conductor cable PVC sheathed in and including concealed in brick wall/RCC as per the site condition providing suitable PVC conduit with 4 runs of 10.0 Sqmm and 2 runs of 10.0 Sqmm FRLS copper conductor as earth wire and connected to earth dolly complete all as specified and as directed by Engr-in-Charge. Note: (i) The work includes cutting of Chassis and making good to match with surrounding necessary periodical applied one coat of putty and one coat of oil bound distemper to be included in quoted rate. (ii) One unit run shall include 6 runs of 10 Sqmm wire, conduit shall be measured as one unit.
M&L in replacement for modular socket outlet 6A, 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for modular socket outlet 6A/16A, 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for modular switch 1 way 6 Amps 1 module suitable for 230 Volts AC Supply complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for modular switch 2 way 6 Amps 1 module, suitable for 230 Volts AC Supply. Make: Anchor Roma/Havells
M&L in replacement for modular switch 1 way 16 Amps 1 module, suitable for 230 Volts AC Supply complete all as specified and as directed by Engr-in-Charge.
M&L for ceiling rose 3 phase/PVC/ polycarbonate isolated body complete all as specified and as directed by Engr-in-Charge.
S&F step type electronic fan regulator Modular type, single phase 220 V, one module type complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Ding Dong Bell, single phase, 230 volt AC,50 HZ complete all as specified and as directed by Engr-in-Charge.
M&L in replacement, Batten holder bakelite, AC supply 220 Volts complete all as specified and as directed by Engr-in-Charge.
M&L for Bell push, Modular type, one module, suitable for 230 Volts AC Supply complete all as specified and as directed by Engr-in-Charge.
M&L for Switch Piano flush type single pole one way 5 Amp complete all as specified and as directed by Engr-in-Charge.
M&L for Switch Piano flush type single pole one way 15 Amp complete all as specified and as directed by Engr-in-Charge.
M&L for socket outlet 3 Pin, 2 in 1 of 5 Amp capacity complete all as specified and as directed by Engr-in-Charge.
M&L for socket outlet 3 Pin, 2 in 1 of 15 Amp Capacity complete all as specified and as directed by Engr-in-Charge.
M&L for Switch Socket Combination 2 in 1, 3 Pin 5 Amps and 15 Amp flush type complete all as specified and as directed by Engr-in-Charge.
M&L for Switch Socket Combination 2 in 1, 3 Pin 5 Amps flush type complete all as specified and as directed by Engr-in-Charge.
Taking down old unserviceable Plug & Socket DB and M&L for distribution boards in sheet metal enclosure single pole and neutral with two pin and earth plug and socket with one single pole MCB 240 Volts of 20 Amps complete all as specified and as directed by Engr-in-Charge. Make: Cat No DBMPS120SD of L&T/Cat No DHCUSN020 of Havells
Taking down old unserviceable MCB DB and M&L for distribution boards in sheet metal enclosure for MCB's DB, 8 way (SPN) 200 Amps rated bus bar complete all as specified and as directed by Engr-in-Charge. Make: Cat No BBSPN00854SD of L&T/Havells Cat No DHDPSHOSRW08/Legrand Cat No 507613
Taking down old unserviceable MCB DB and M&L for distribution boards in sheet metal enclosure triple pole and neutral 415 Volts, 4 way (TPN) double door type fixed with concealed on walls or on surface and matching with existing surface complete all as specified and as directed by Engr-in-Charge. Make: Cat No DBPSG004DD of L&T/Havells Cat No DHDPTVODRW04
Taking down old unserviceable MCB DB and M&L for distribution boards in sheet metal enclosure triple pole and neutral vertical Load line 415 Volts, 8 way (TPN) Double door type fixed with concealed on walls or on surface and matching with existing surface complete all as specified and as directed by Engr-in-Charge. Make: Cat No DBPSG008DD of L&T/Havells Cat No DHDPTVODRW08
Taking down old unserviceable MCB DB and M&L for distribution boards in sheet metal enclosure triple pole and neutral vertical Load line 415 Volts, 8 way IP-43 of metal double door type with One 100 Amps, 4 Pole MCCB complete all as specified and as directed by Engr-in-Charge. Note: Rate of MCCB shall deemed to be in quoted rates Make: Cat No DBPGL008SD of L&T/Havells Cat No DHDLVDRWGOFOO4
M&L for MCB 240 volts, SP 6-32 amp, 10KA breaking capacity complete all as specified and as directed by Engr-in-Charge.
M&L for MCB 415 volts TPN 63 amp 10 KA breaking capacity complete all as specified and as directed by Engr-in-Charge. Make: Cat No DHMSGCTNF063 of L&T/Havells Cat No AU10ST0633C
S&F MCCB 250 Amps 4 pole 415 Volts of 25 KA breaking capacity complete all as specified and as directed by Engr-in-Charge. Make: Cat No CM90634OOPO of L&T/Havells Cat No IHLANDCF0250#
S&F MCCB 400 Amps 4 pole 415 Volts of 36 KA breaking capacity complete all as specified and as directed by Engr-in-Charge. Make: Cat No CM98403OOROOG of L&T/Havells Cat No IHLLSEBF0400#
S&F MCCB 630 Amps 4 pole 415 Volts of 50 KA breaking capacity complete all as specified and as directed by Engr-in-Charge. Make: Cat No CM94104OOT1OG of L&T/Havells Cat No IHLLNFBF0630#
Taking out old unserviceable fitting and S&F wall mounted LED batten 20 watt, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 230 Volt, including all accessories prewired including 1 No LED tube and making necessary electrical connection with 3 core copper conductor and testing complete all as specified and as directed by Engr-in-Charge. Make: Cat No LD00103031 of Polycab/Cat No ENDURA LINEARNEOBS20WLED865SPCWH of Havells
S&F in replacement wall mounted LED batten 10 watt, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver, 230 Volt, including all accessories prewired including 1 No LED tube and making necessary electrical connection with 3 core copper conductor and testing complete all as specified and as directed by Engr-in-Charge. Make: Cat No LD00103028 of Polycab/Cat No ENDURA LINEARNEOBS10WLED865SPCWH of Havells
S&F in replacement 2'x2' size LED panel lighting luminaire glare free illumination suitable for false ceiling (Armstrong/ Grid) fitting size 600x600x70 mm (LXWXH) of 42 watts capacity recess mounting with high brightness SMD LEDs including taking down old unserviceable complete all as specified and as directed by Engr-in-Charge. Make: Cat No SSK-PL-45W SQ5.7K/SK SRF of Syska/Cat No VENUSNEOHE2XPLR18-42WLED865 MOD of Havells/Cat No LTCRP45WLED2x2 of C&S
S&F in replacement surface mounting of size 1 feet x 1 feet LED panel lighting luminaire glare free illumination suitable for surface mounting square slim down light white of size 300x300x70 mm (LXWXH) of 18/20 watt recess mounting with high brightness SMD LED including taking down old unserviceable fittings complete all as specified and as directed by Engr-in-Charge. Make: Cat No SSK-3030-17 of Syska/ Cat No PLUTO 1X1PLR15WLED857S of Havells/ Cat No LTCRP18WLED1x1 of C&S
S&F Energy saving new generation 12 watt LED bulk head luminaries with Opal diffuser 230V, single phase with all accessories and all electrical connections complete all as specified and as directed by Engr-in-Charge. Make: Cat No LHEBAEP5IZ1W012 of Havells/Cat No SIRIUS/12W of C&S
M&L in replacement oil filled capacitor of 2.5 mfd capacity 240 Volt AC supply 50 Hz complete all as specified and as directed by Engr-in-Charge.
S&F in replacement LED lamp 7 watt suitable for B22 base complete all as specified and as directed by Engr-in-Charge.
S&F in replacement copper wire in wiring circuits as per site requirements PVC insulated single core 1.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
S&F in replacement copper wire in wiring circuits as per site requirements PVC insulated single core 2.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
S&F in replacement copper wire in wiring circuits as per site requirements PVC insulated single core 4 Sqmm 1100 volts grade multi stranded conductor complete all as specified and as directed by Engr-in-charge.
M&L in replacement street light for building IP 65 of 25 watt capacity LED type with high power LEDs fabricated and die cast aluminium housing suitable for general purpose lighting complete and for single phase, 230 V, AC, 50 Hz complete all as specified and directed by Engr-in-charge.
Disconnecting and taking down of existing unserviceable KWH meter of any description and in any position for testing, conducting test for the same with suitable load submitting the test result obtained during testing and depositing the meter to MES store yard of AGE E/M (AF) Tughlakabad complete all as specified and as directed by Engr-in-charge
S&F electronic type static watt hour electrical energy meter pamper proof made out of poly carbonate casing of class 1.0 accuracy confirming to IS-13779 and CBIP technical report 88 suitable for LT single phase two wire AC 230 Volt, 50 Hz 5 to 30 Amps with fully tamper proof low consumption LCD display bakelite, LT RTC optical communication port with facility storage of data and for downloading of data as and when required including sealing of meters and writing of MES No etc. complete all as specified and as directed by Engr-in-charge.
S&F electronic type static watt hour electrical energy meter pamper proof made out of poly carbonate casing of class 1.0 accuracty confirming to IS-13779 and CBIP technical report 88 suitable for LT three phase four wire AC 430 Volt, 50 Hz 10 to 40 Amps with fully tamper proof low consumption LCD display bakelite, LT RTC optical communication port with facility storage of data and for downloading of data as and when required including sealing of meters and writing of MES No etc. complete all as specified and as directed by Engr-in-charge.
S&F in repair Voltmeter of capacity 0 to 500 Volts digital type, square type 96mm x 96mm complete all as specified and as directed by Engr-in-charge.
S&F in repair CT 100/5 Amps complete all as specified and as directed by Engr-in-charge.
S&F in replacement 15 Amp 3 pin plug top complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular white cover plate with frame of 3 module complete all as specified and directed by Engr-in-charge.
M&L in replacement of modular white cover plate with frame of 8 module complete all as specified and directed by Engr-in-charge.
M&L in replacement of modular metal flush box for 3 module complete all as specified and directed by Engr-in-charge.
M&L in replacement of modular metal flush box for 8 module complete all as specified and directed by Engr-in-charge.
Notes: The amount of Rs 66,227.00 against schedule of credit given on Tender page No 36(R) shall be deducted from the total amount quoted by the contractor against BOQ while deriving the contract sum for acceptance.
V r traders
Skyline Encon
akenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .