| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC NEAR GYAN DEEP SCHOOL 1 DHARAM KANTA GOVERDHAN ROAD DISTT MATHURA U P 281001 | MATHURA | MATHURA | U P | 281001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.8 L+₹1.2 L (3.78%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹34.4 L+₹2.8 L (8.91%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹34.7 L+₹3.1 L (9.95%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹35.5 L+₹4.0 L (12.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | krishna Associate L5 | DEMROT ELECTRICAL WORKS L6 | M/s Ranaji Construction Co L3 | M/s Prayag Construction L7 | Vijay Electricals L8 | PD GUPTA AND COMPANY L2 | PRABHAT ENGINEERING SOLUTION AND SERVICES L4 | M/S BAJRANG CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & Fix & connecting totally enclosed CMRI Certified in replacement of LED flameproof wellglass suitable for hazardous area laden with gases or vapours of Group IIA & IIB and Zone 1&2. Die Cast Aluminum housing with heat resistant toughened glass cemented into a retaining ring fixed with screws to the main housing external reflector 50W including matching control gears and lamp complete all as specified. | 80 | Each | 5,000 ₹4,00,000 | 8,000 ₹6,40,000 | 7,550 ₹6,04,000 | 6,200 ₹4,96,000 | 8,000 ₹6,40,000 | 6,500 ₹5,20,000 | 4,250 ₹3,40,000 Lowest | 7,500 ₹6,00,000 |
| 2.00 | Taking down of old unserviceable copper / aluminium point wiring (light) with conduit complete including fitting & fixture such as switches, ceiling roses, light fitting etc and making good disturbed surfaces of walls, floors etc complete all as specified. | 75 | Per Point | 20 ₹1,500 | 20 ₹1,500 | 20 ₹1,500 | 50 ₹3,750 | 35 ₹2,625 | 15 ₹1,125 | 9 ₹675 | 5 ₹375 Lowest |
| 3.00 | All as item No 02 Above but without conduit. | 190 | Per Point | 20 ₹3,800 | 20 ₹3,800 | 18 ₹3,420 | 30 ₹5,700 | 35 ₹6,650 | 10 ₹1,900 | 9 ₹1,710 | 5 ₹950 Lowest |
| 4.00 | Taking down old unserviceable sub main wiring of any size complete all as specified. | 300 | RM | 10 ₹3,000 | 10 ₹3,000 | 10 ₹3,000 | 30 ₹9,000 | 25 ₹7,500 | 10 ₹3,000 | 9 ₹2,700 | 5 ₹1,500 Lowest |
| 5.00M&L concealed point wiring complete with two runs of 2.5 sqmm, single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable, 1100volts grade drawn through and including rigid steel ERW conduit min 20mm dia ( stove enameled) heavy duty including all necessary flame proof , weather proof conduit accessories and fitting fixed to concealed in wall/ceiling with teflon tape sealed in all threaded joints in conduit and fittings for light points and including 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade earth continuity wire (connecting to earth dolly) & wiring shall be done as directed for the following :- | |||||||||||
| 5.01 | (a) Two light points controlled by one Rotary switch/MCB | 45 | Per Point | 1,500 ₹67,500 | 2,500 ₹1,12,500 | 1,500 ₹67,500 | 2,100 ₹94,500 | 1,800 ₹81,000 | 1,000 ₹45,000 Lowest | 1,400 ₹63,000 | 1,000 ₹45,000 Lowest |
| 5.02 | (b) Three light points controlled by one Rotary switch/MCB | 30 | Per Point | 1,500 ₹45,000 | 4,000 ₹1,20,000 | 2,000 ₹60,000 | 2,900 ₹87,000 | 1,900 ₹57,000 | 1,200 ₹36,000 Lowest | 1,400 ₹42,000 | 1,200 ₹36,000 Lowest |
| 6.00 | All as per item No 05 Above but for Two light points controlled by one switch/MCB with copper cables 2.5 sqmm size. (in existing conduit) complete all as specified. | 95 | Per Point | 1,500 ₹1,42,500 | 2,700 ₹2,56,500 | 700 ₹66,500 | 1,400 ₹1,33,000 | 1,500 ₹1,42,500 | 600 ₹57,000 Lowest | 1,700 ₹1,61,500 | 900 ₹85,500 |
| 7.00 | All as per item No 05 Above but for one light points controlled by one switch/MCB with copper cables 2.5 sqmm size. (in existing conduit) complete all as specified. | 95 | Per Point | 1,500 ₹1,42,500 | 2,400 ₹2,28,000 | 650 ₹61,750 | 900 ₹85,500 | 1,930 ₹1,83,350 | 550 ₹52,250 Lowest | 1,700 ₹1,61,500 | 2,000 ₹1,90,000 |
| 8.00 | Supply and fixing in replacement of factory made mild steel flame proof distribution boards, class LM-6 , protection class (IP-55) CMRI certified suitable for gas group IIA & IIB suitable for mounting MCB/RCCBs, DBs TP&N 4 way, 415 volts conforming to IS-2143 with minimum 200A rating copper bus bar Comprising of following :-
(i) Lighting distribution panel
(ii) Incoming: - MCB , 4P 63AMP - 01 Nos
(iii) Outgoing :- MCB, 1P, 6 to 32 AMP -12Nos | 13 | Each | 48,000 ₹6,24,000 | 25,000 ₹3,25,000 Lowest | 37,000 ₹4,81,000 | 40,000 ₹5,20,000 | 48,000 ₹6,24,000 | 40,000 ₹5,20,000 | 35,000 ₹4,55,000 | 42,000 ₹5,46,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Mar 2026, 6:00 pmClosed
GE Bharatpur
GE Bharatpur
REPAIR REPLACEMENT OF FLAME PROOF WIRING FLAME PROOF LIGHT FITTING AND FLAME PROOF DB AT ESH SHED INSIDE DEPOT AREA AND OTHER CONNECTED WORK AT MIL STN BHARATPUR
2026_MES_750400_2
8582/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Bharatpur
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE Bharatpur
₹90,000
Yes
30 Mar 2026
28 Feb 2026
16 Mar 2026
28 Feb 2026
14 Mar 2026
7 Mar 2026
1 Mar 2026 - 6 Mar 2026
Supply & Fix & connecting totally enclosed CMRI Certified in replacement of LED flameproof wellglass suitable for hazardous area laden with gases or vapours of Group IIA & IIB and Zone 1&2. Die Cast Aluminum housing with heat resistant toughened glass cemented into a retaining ring fixed with screws to the main housing external reflector 50W including matching control gears and lamp complete all as specified.
Taking down of old unserviceable copper / aluminium point wiring (light) with conduit complete including fitting & fixture such as switches, ceiling roses, light fitting etc and making good disturbed surfaces of walls, floors etc complete all as specified.
All as item No 02 Above but without conduit.
Taking down old unserviceable sub main wiring of any size complete all as specified.
M&L concealed point wiring complete with two runs of 2.5 sqmm, single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable, 1100volts grade drawn through and including rigid steel ERW conduit min 20mm dia ( stove enameled) heavy duty including all necessary flame proof , weather proof conduit accessories and fitting fixed to concealed in wall/ceiling with teflon tape sealed in all threaded joints in conduit and fittings for light points and including 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade earth continuity wire (connecting to earth dolly) & wiring shall be done as directed for the following :-
(a) Two light points controlled by one Rotary switch/MCB
(b) Three light points controlled by one Rotary switch/MCB
All as per item No 05 Above but for Two light points controlled by one switch/MCB with copper cables 2.5 sqmm size. (in existing conduit) complete all as specified.
All as per item No 05 Above but for one light points controlled by one switch/MCB with copper cables 2.5 sqmm size. (in existing conduit) complete all as specified.
Supply and fixing in replacement of factory made mild steel flame proof distribution boards, class LM-6 , protection class (IP-55) CMRI certified suitable for gas group IIA & IIB suitable for mounting MCB/RCCBs, DBs TP&N 4 way, 415 volts conforming to IS-2143 with minimum 200A rating copper bus bar Comprising of following :- (i) Lighting distribution panel (ii) Incoming: - MCB , 4P 63AMP - 01 Nos (iii) Outgoing :- MCB, 1P, 6 to 32 AMP -12Nos
Supply and fixing in replacement of switch flame proof rotary type with termination box in LM6, 16 Amps single pole, 250 volts epoxy painted complete all as specified.
Supply and fixing in replacement of switch flame proof rotary type with termination box in LM6, 25 Amps double pole, 250 volts epoxy painted complete all as specified.
Supply and fixing in replacement of LED flameproof tube light fitting CMRI certified 1x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified.
Supply and fixing in replacement of LED flameproof tube light fitting CMRI certified 2x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified.
Supply and fixing in replacement of MCB SPN 6 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified.
Supply and fixing in replacement of MCB SPN 16 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified.
Supply and fixing in replacement of MCB TPN 32 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified.
Supply in repair MCCB 63 Amp, 4 Pole, fixed type breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified.
Supply in repair MCCB 100 Amp, 4 Pole, fixed type breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes :-
(a) 25 Sqmm 4 core
(b) 16 Sqmm 4 core
(c) 16 Sqmm 2 core
(d) 10 Sqmm 2 core
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified.
Demolition of Concrete in ground floors and pavings not exc 15cm thick( below or above ground floors) complete all as specified.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid and tested complete all as specified.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable complete all as specified. Note : Punned thickness shall be measured.
Supply and laying of sub class 'B' bricks in trenches over cables for protection cover across the length of cable complete all as specified.
M&L for driling hole in hard standing / road for laying of pipe for protection of cable etc by adopting method of horizontal manual drilling (trenchless technology) without disturbing the top surface or cutting and making good the disturbed surface to the existing surface complete all as specified.
Supply and laying in replacement of GI tube light grade 40 mm bore complete all as specified.
M&L sub main wiring with two runs of single core PVC insulated but unsheathed FRLS cable of 4 sqmm with multi stranded copper conductors, 1100 volts grade, IS-694 marked , drawn-through rigid steel ERW conduit (stove enameled) 20 mm dia heavy duty and including suitable size and fittings/accessories, concealed in wall and also including the one run of 4 sqmm earth continuity conductor of similar type cable complete all as specified and directed. Note :- Two runs of single core of 4 sqmm, one run of 4 sqmm earth continuity conductors and one run of 20mm dia ERW conduit with accessories shall be measured as one unit run length complete all as specified.
M & L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 20mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on complete all as specified. Note :- The cost of funnel pipe of 20 mm GI light grade pipe and protection pipe of 20mm bore GI light grade is deemed to be included in quoted unit rate including taking out old unserviceable earthing.
Material and labour for chemical earthing complete with copper earth plate electrode of size 600mm x 600mm x 3 mm thick buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m deep below normal ground connected to and including copper earth strip 25 x 3 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixing with charcoal 250 KG , Crystal salt 200KG , magnesium sulphate of 100 KG and vegetable soil all around the plate up to 350mm above from top edge of plate and balance portion filing with excavated soil in layers not exceeding 25mm thick, 25mm bore galvanised iron medium grade watering pipe up to top of plate, 50mm bore galvanisd iron light grade pipe for earth strip protection, including all excavation earth work in any type of soil, PCC 1:3:6 type C1 for chamber of internal size 300mm x300 x 300mm with 120mm thick wall and 700 mm x 700mm x 150mm thick, bed concrete, RCC 1:2:4, type B1 for precast chamber cover 50mm thick, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/sqm), funnel, with wire mesh, complete all as specified. Note:- (i) Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Taking out of old unsv GI strip and supply & fix copper strip of size 25 x 3 mm complete with insulator/saddle and fixing with screw/ accessories complete all as specified.
Taking out of old unsv GI wire and supply & fix GI wire of size 4mm dia complete with insulator/saddle and fixing with screw/accessories complete all as specified.
M&L in cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles/ coping including necessary formwork, fair finishing to exposed surfaces using extra cement including demolition of PCC complete all as specified.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_845397.xls
BOQ • 0.42 MB
tender8582.pdf
Tender Documents • 1.70 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .