| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAdmitted-Finance | ₹4.8 L | L1 | Admitted-Finance |
| 2 | L2₹5.1 L+₹31,580 (6.59%)Admitted-Finance | ₹5.1 L+₹31,580 (6.59%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Checked and found incorrect |
| Sl No | Description | Qty | Unit | M/S M. T. ENTERPRISES L2 | M/S MD INAYAT HUSSAIN L1 |
|---|---|---|---|---|---|
| 1.00SCHEDULE `A' PART-I (Repair & maint 01 x 100KWP & 02 x 50KWP) | |||||
| 1.10 | Supply, installing, testing and commissioning of solar PV Module- 240W (Photo-Voltaic Cell) as per existing size/capacity complete all as directed and specified. | 22 | Nos | 12,850 ₹2,82,700 | 12,500 ₹2,75,000 Lowest |
| 1.20 | Supplying and fixing of Metal Oxide Varistor (MOV) suitable for input and output protection, complete with connections, mounting, testing and commisioning as required including circuit board connection directed by Engr-in-Charge. | 2 | Set | 17,050 ₹34,100 | 17,000 ₹34,000 Lowest |
| 1.30 | Supply, laying, connection, testing and commissioning of Solar DC cable of 6.00 Sqmm complete all as directed and specified | 800 | RM | 180 ₹1,44,000 | 150 ₹1,20,000 Lowest |
| 1.40 | Supply, Installing, testing and commissioning of battery bank of suitable capacity 2V 600 AH VRLA and connecting in existing system by taking down old unserviceable battery bank from system complete & make the plant functional in all respects including connection upto inverter complete all as specified & directed. | 4 | Nos | 4,800 ₹19,200 | 4,500 ₹18,000 Lowest |
| 1.50 | Repair and maint of old existing inverter of suitable capacity wrt system voltage by inspecting, repair of replacement of internal part complete along with DC wiring connectrions and make the inverter functional by connecting to existing battery bank al as specified and directed as per Engr-in-charge. | 1 | Each | 26,000 ₹26,000 | 25,000 ₹25,000 Lowest |
| 1.60 | Supplying and installation of lighting Arrestor w.r.t suitable capacity of existing 01 x 100 KWP solar power plant incl connection of air termination system, testing and commisioning. | 2 | Set | 4,650 ₹9,300 | 4,500 ₹9,000 Lowest |
| 2.00SCHEDULE `A' PART-II (Schedule of Credit) | |||||
| 2.10 | Credit of Amount (ie minus): Old unserviceable PV Module (Photo-Voltaic Cell) of 100 KWP solar plant in respect to Item No. 01 | 22 | Nos | 100 ₹-2,200 | 40 ₹-880 Lowest |
| 2.20 | Credit of Amount (ie minus): Old unserviceable battery bank in respect to Item No. 04 | 4 | Nos | 650 ₹-2,600 | 300 ₹-1,200 Lowest |
Tender Value
₹4.8 L
EMD Value
₹9,600
Closing Date
16 Jun 2026, 9:00 amClosed
DIG AR
SO-1 (Wks) HQ 9 Sect AR (Engr Branch) Keithelmanbi (Manipur)
Term contract for operation and maint of existing solar power plant of 02 x 50 KWP and 01 x 100 KWP at HQ 9 Sector AR, Keithelmanbi
2026_ARMHA_911393_1
VIII.11011/9 Sect/Engr-AMC/NIT/2026-27/02
Open Tender
Civil Works - Others
Works
180 days
HQ 9 Sect AR, Keithelmanbi (Manipur)
Term contract for operation and maint of existing solar power plant of 02 x 50 KWP and 01 x 100 KWP at HQ 9 Sector AR, Keithelmanbi
2 documents required · 2 mandatory
₹1,000
DIG AR, HQ 9 Sect AR
₹9,600
22 Jun 2026
3 Jun 2026
17 Jun 2026
3 Jun 2026
16 Jun 2026
3 Jun 2026
3 Jun 2026 - 16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SCHEDULE `A' PART-I (Repair & maint 01 x 100KWP & 02 x 50KWP) | |||||
| 1.1 | Supply, installing, testing and commissioning of solar PV Module- 240W (Photo-Voltaic Cell) as per existing size/capacity complete all as directed and specified. | 22 | Nos | - | - |
| 1.2 | Supplying and fixing of Metal Oxide Varistor (MOV) suitable for input and output protection, complete with connections, mounting, testing and commisioning as required including circuit board connection directed by Engr-in-Charge. | 2 | Set | - | - |
| 1.3 | Supply, laying, connection, testing and commissioning of Solar DC cable of 6.00 Sqmm complete all as directed and specified | 800 | RM | - | - |
| 1.4 | Supply, Installing, testing and commissioning of battery bank of suitable capacity 2V 600 AH VRLA and connecting in existing system by taking down old unserviceable battery bank from system complete & make the plant functional in all respects including connection upto inverter complete all as specified & directed. | 4 | Nos | - | - |
| 1.5 | Repair and maint of old existing inverter of suitable capacity wrt system voltage by inspecting, repair of replacement of internal part complete along with DC wiring connectrions and make the inverter functional by connecting to existing battery bank al as specified and directed as per Engr-in-charge. | 1 | Each | - | - |
| 1.6 | Supplying and installation of lighting Arrestor w.r.t suitable capacity of existing 01 x 100 KWP solar power plant incl connection of air termination system, testing and commisioning. | 2 | Set | - | - |
| 2SCHEDULE `A' PART-II (Schedule of Credit) | |||||
| 2.1 | Credit of Amount (ie minus): Old unserviceable PV Module (Photo-Voltaic Cell) of 100 KWP solar plant in respect to Item No. 01 | 22 | Nos | - | - |
| 2.2 | Credit of Amount (ie minus): Old unserviceable battery bank in respect to Item No. 04 | 4 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
NIT02.pdf
Tender Documents • 1.26 MB
BOQ_957848.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .