| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹18.0 LAdmitted-Finance | -2.51% | ₹18.0 L | L1 | Admitted-Finance |
| 2 | L2₹19.0 LAdmitted-Finance | +3.00% | ₹19.0 L | L2 | Admitted-Finance |
| 3 | L3₹19.8 LAdmitted-Finance A 86 MANISH MARG NEMI NAGAR VAISHALI NAGAR JAIPUR JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | +7.00% | ₹19.8 L | L3 | Admitted-Finance |
Tender Value
₹21.8 L
EMD Value
₹43,640
Closing Date
11 May 2026, 11:00 amClosed
SE CIVIL JAIPUR
CHAMBAL POWER HOUSE HAWA SADAK SODALA JAIPUR
Providing and fixing of Air conditioners at 220 KV GIS IG Nagar Jaipur
2026_RRVPN_555949_2
RVPN/SE/CIVIL/JPR/NIT-02/26-27
Open Tender
Civil Works
60 days
220KV GIS IG Nagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
ACCOUNTS OFFICER T AND C RRVPNL JAIPUR CITY
₹43,640
Yes
25 May 2026
4 May 2026
12 May 2026
4 May 2026
11 May 2026
4 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | 22.25.7 Supply , Installation, Testing and Commissioning of Inverter type Air cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity up to 42 Degree Celsius ambient temperature. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 degree C (out door ambient temperature) Cooling capacity 6800-7000 Watt, ISEER not less then 3.8 | 15 | Each | - | - | BI01010001010000000000000515BI0100001113 |
| 2 | 22.26.3 Supply , Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 415 V +/- 10% ,3 phase 50 Hz AC Supply with low & high voltage cutoff and capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Cooling capacity 14000 Watt, ISEER not less then 3.0 | 6 | Each | 0.2 | ₹1.2 | BI01010001010000000000000515BI0100001118 |
| 3 | 6.12.3 P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required.20 amp, (2P + E), 3 Module | 21 | each | - | - | BI01010001010000000000000515BI0100001119 |
| 4 | 22.44.1 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes.20 mm | 100 | mtr | 131 | ₹13,100 | BI01010001010000000000000515BI0100001120 |
| 5 | 22.45.3 Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. 5 kva | 21 | Each | - | - | BI01010001010000000000000515BI0100001121 |
| 6 | 22.46.1 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 50 mm dia per running inch length | 200 | per inch | 67 | ₹13,400 | BI01010001010000000000000515BI0100001122 |
| 7 | 22.48 Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 15 | Each | - | - | BI01010001010000000000000515BI0100001123 |
| 8 | 22.52 SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. as required. | 20 | kg | - | - | BI01010001010000000000000515BI0100001124 |
| 9 | E-4.7.2 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.2.5 Sq.mm 3 core flat / Round. | 100 | mtr | - | - | BI01010001010000000000000515BI0100001125 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.22 MB
Tendernotice_2.pdf
PDF • 0.36 MB
BOQ_990142.xls
BOQ • 0.29 MB
New_Alldocuments.pdf
Tender Documents • 6.53 MB
Download all tender documents and submit your bid