Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | ₹29.4 L Quoted ₹30.4 L | L1 | Accepted-AOC Eligible |
| 2 | L2₹31.6 LRejected-AOC 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹31.6 L | L2 | Rejected-AOC Not eligible |
| 3 | L3₹35.6 LRejected-AOC WZ 109 PLOT NO 327 CHAND NAGAR NEW DELHI | ₹35.6 L | L3 | Rejected-AOC Not eligible |
| Sl No | Description | Qty | Unit | RAJENDER ENTERPRISES L1 | Suman Uni Controllers L3 | PANWAR ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for servicing of flame proof EOT Crane capacity 3 ton of Make : TIB UDHYOG for (WSA-III) by the following method as follows : (a) Replacement of gear oil in gear boxes . (b) Grease the whole crane (c) Before filling the gear boxes clean the gear box inside and outside by using diesel (d) Checking the wheel condition (e) If thruster breaks are used check the leve of oil in it and if required to be refilled , refill the same (f) Check the working of the break if required to change then change the same (g) Checking the connection of motors (h) Checking the condition of motor if required if required to rewind ,n rewind the same (i) Checking the condition of couplings if required to be change then change the same (k) Check the nuts & bolts fitted on the crane , if required to be change then change the same (l) Check the condition of the power cables fitted on the crane , if required to be change then change the same . (m) Check the break shoe fitted on the break of the crane , if required then change the same | 25 | Each Job | 16,200 ₹4.0 L | 17,600 ₹4.4 L | 5,000 ₹1.3 L |
| 1.01(n) Check the limit switch fitted on the crane , if required then replace the same . (o) Check the step down transformer , single phase preventer , terminal block , MCB , HRC and DBR , if required to be change then change the same . (p) If VFD installed , check the same and if required then replace the same (q) Check the pendant , if element and push button required to be change then replace the same . Note : (i) All unserviceable spare parts to be replaced shall be measured and paid separately under relevant item of Sch A. (ii) Cost of Grease & Oil shall be deemed included in unit quoted rate. (iii) Servicing of crane shall be carried out through OEM only . Contractor shall have to submit the MoU with the concerned OEM for maintenance of crane before the issue of work order . (iv) After servicing, OEM has to submit the serviceability certificate and warranty for the replaced items for one year from the date of servicing . | ||||||
| 2.00 | All as per ser item no 1.0 above here in before but for Make : Endurance 3.0 ton capacity flame proof EOT crane . | 12 | Each Job | 16,200 ₹1.9 L | 17,600 ₹2.1 L | 5,000 ₹60,000 |
| 3.00 | All as per description of item No. 1.0 above here in before but HOT/EOT Crane, 3 TON Capacity ,for WSA-II ,Make : TIB UDHYOG | 20 | Each Job | 16,200 ₹3.2 L | 17,000 ₹3.4 L | 3,000 ₹60,000 |
| 4.00 | Load testing of flame proof EOT Crane 3 TON for WSA-III Capacity of any make and model, comprising two number tests for each crane i.e. Capacity test and Brake Test as per IS : 3177 of 197 by putting the requisite load, writing date of test and next due date for testing on the crane with white synthetic enamel paint over a black strip of synthetic enamel paint complete all as directed .
Note:- (i)M & L for Load for testing shall be arranged by the contractor at his own and the rate of this item include the cost thereof.
(ii) Testing of particular crane shall be scheduled by Engineer-in-Charge
(iii) Load testing and caliberation of EOT crane carried out in the presence of competent person under factories act 1963 and rep of OEM and after completion of load testing contractor will produced the Form 11 duly signed by competent person under factories Act 1963. | 25 | Each Job | 6,300 ₹1.6 L | 8,100 ₹2.0 L | 5,000 ₹1.3 L |
| 5.00 | All as per ser item no 4.0 above but for Make : Endurance 3.0 ton capacity flame proof EOT crane . | 12 | Each Job | 6,300 ₹75,600 | 8,000 ₹96,000 | 5,000 ₹60,000 |
| 6.00 | All as per description of item No. 4.0 above here in before but HOT/EOT Crane, 3 TON Capacity for WSA-II ,Make : TIB UDHYOG | 20 | Each Job | 5,400 ₹1.1 L | 7,000 ₹1.4 L | 5,000 ₹1 L |
| 7.00Supply only following Spares / Components for existing flame proof EOT crane 3 TON capacity complete all as specified and directed:- | ||||||
| 7.01 | Gear oil ( ISI Marked ) of 80W-90 grade for filling in the gear boxes upto specified level under the relevent item of the schedule all as directed . | 350 | Ltrs | 333 ₹1.2 L | 320 ₹1.1 L | 200 ₹70,000 |
| 7.02 | Hydraulic oil (ISI Marked ) of approved grade for filling in the electrohydraulic thruster upto specified level . | 200 | Ltrs | 252 ₹50,400 | 245 ₹49,000 | 200 ₹40,000 |
Updated dates
Tender Value
₹36.2 L
EMD Value
₹72,440
Closing Date
2 Jan 2026, 6:00 pmClosed
CWE AF BIKANER
HQ CWE AF BIKANER
COMPREHENSIVE MAINTEANANCE OF LIFT AND REPAIR/ MAINTENANCE OF EOT CRANE,MOTORIZED GATE AND OTHER CONNECTED WORK AT AF STN NAL
2025_MES_743276_1
C-81642/E8
Open Tender
Civil Works
180 days
GE AF NAL
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF NAL
₹72,440
Yes
2 Mar 2026
5 Dec 2025
5 Jan 2026
5 Dec 2025
2 Jan 2026
19 Dec 2025
Amount
M&L for servicing of flame proof EOT Crane capacity 3 ton of Make : TIB UDHYOG for (WSA-III) by the following method as follows : (a) Replacement of gear oil in gear boxes . (b) Grease the whole crane (c) Before filling the gear boxes clean the gear box inside and outside by using diesel (d) Checking the wheel condition (e) If thruster breaks are used check the leve of oil in it and if required to be refilled , refill the same (f) Check the working of the break if required to change then change the same (g) Checking the connection of motors (h) Checking the condition of motor if required if required to rewind ,n rewind the same (i) Checking the condition of couplings if required to be change then change the same (k) Check the nuts & bolts fitted on the crane , if required to be change then change the same (l) Check the condition of the power cables fitted on the crane , if required to be change then change the same . (m) Check the break shoe fitted on the break of the crane , if required then change the same
All as per ser item no 1.0 above here in before but for Make : Endurance 3.0 ton capacity flame proof EOT crane .
All as per description of item No. 1.0 above here in before but HOT/EOT Crane, 3 TON Capacity ,for WSA-II ,Make : TIB UDHYOG
Load testing of flame proof EOT Crane 3 TON for WSA-III Capacity of any make and model, comprising two number tests for each crane i.e. Capacity test and Brake Test as per IS : 3177 of 197 by putting the requisite load, writing date of test and next due date for testing on the crane with white synthetic enamel paint over a black strip of synthetic enamel paint complete all as directed . Note:- (i)M & L for Load for testing shall be arranged by the contractor at his own and the rate of this item include the cost thereof. (ii) Testing of particular crane shall be scheduled by Engineer-in-Charge (iii) Load testing and caliberation of EOT crane carried out in the presence of competent person under factories act 1963 and rep of OEM and after completion of load testing contractor will produced the Form 11 duly signed by competent person under factories Act 1963.
All as per ser item no 4.0 above but for Make : Endurance 3.0 ton capacity flame proof EOT crane .
All as per description of item No. 4.0 above here in before but HOT/EOT Crane, 3 TON Capacity for WSA-II ,Make : TIB UDHYOG
Supply only following Spares / Components for existing flame proof EOT crane 3 TON capacity complete all as specified and directed:-
Gear oil ( ISI Marked ) of 80W-90 grade for filling in the gear boxes upto specified level under the relevent item of the schedule all as directed .
Hydraulic oil (ISI Marked ) of approved grade for filling in the electrohydraulic thruster upto specified level .
Oil Seal.
Over Load Relay 10 to 32 Amps
Clutch Plate.
Brake lining as per existing
Pedant Push Button with auxillary contacts
Magnetic coil for brake
Gear wheel
HRC Fuse 10 Amps,
HRC Fuse 16 Amps,
Indicator Lamp (RYB) as per existing
Long travel bridge drive wheel bronze coating suitable for flame proof EOT crane of capacity 3 Ton complete all as specified and directed.
Cross travel bridge drive wheel bronze coating suitable for flame proof EOT crane of capacity 3 Ton complete all as specified and directed.
Ball bearing along with shaft seal / 'O' seal / 'V" seal of shaft on main hoist wire rope drum on both side for 3 Ton capacity gear box for main hoist .
Ball bearing along with shaft seal / 'O' seal / 'V" seal of shaft on both side for Cross Travel for 3 Ton EOT capacity gear box for main hoist .
Ball bearing along with shaft seal / 'O' seal / 'V" seal of shaft on both side for Long Travel for 3 Ton EOT capacity gear box for main hoist .
Flame proof thruster brake shoes suitable for 3 ton EOT / HOT crane of size 100mm x 125 mm x 12 mm thick as per existing at site with necessary copper rivets etc complete
Neoprine gasket
Flame proof Enclosure of existing make and size (as per sample)
Flame proof copper cable of size 6 Sqmm 3 core in steel condiut of size 20mm . Three runs of copper wire and one run of steel condiut shall be considered as one unit for measurement purpose.
Thruster break of required size (as per sample)
Break plunnger
M&L for grease suitable for flameproof EOT crane up to 5 Ton cap as per manufacture recommendation or directed by Engr In Charge.
Material and labour for repair the Flame proof electro hydraulic thruster & brake of capacity 3 ton with gear holding brakes of Hoist/creep/ cross travel and long travel , rewinding the burnt out winding of electrohydraulic thruster motor with super enamel copper wire of existing gauge and varnishing , heating and testing etc complete repairing of oil pump by replacing worn out parts , oil seal , 'O' ring and bush and bearing -02 No , check nuts , lock pin all as required including draining out old unserviceable oil complete all as specified and as directed . Note : (i) Repair of thruster shall be carried out through authorised service agency of original Equipment Manufacturer (OEM) . The contractor shall submit documentary proof/evidence in this regard before taking thruster under repair (ii) Make and model of part to be replaced shall be used /recommended by OEM.
Main hoist thruster of 3 ton EOT Crane.
Cross Travel thruster of 3 ton EOT Crane.
Long Travel thruster of 3 ton EOT Crane.
Supply and fix in repair flame proof three phase lever type limit switch as per site , suitable for 3 ton capacity EOT crane for main hoist / long travel / Cross travelof of make as used / recommended by OEM , complete all as specified and as directed .
Supply and fixing galvanised steel wire rope conforming to IS-2266-2002 of nominal diameter of 9mm having 6 x 19M (12/6-1) multi stranded construction steel core CRW grade 1570, having mass 30.8 Kg/100 RM with minimum breaking force of 42 KN suitable for lifting load of 3 ton including greasing complete all as specified and as directed including taking down old unserviceable steel rope . Make : Usha/Bombay foot/National or as used/recommended by OEM . Note : (i) The steel rope shall be best performed plough straight non rotating type conforming to IS-2266. (ii) The breaking strength of the rope shall not be less than 6 times the safe working load thereon . (iii) The test certificate of manufacturer shall be submitted by the contractor.
Comprehensive maintenance and servicing of passenger elevator of capacity 08 passenger, KONE Make speed limit 1.50 metre / sec equipped with microprocessor based AC variable voltage & variable frequency controller (VVFD), AC motor governor, ropes driving sheave, travelling cable, microprocessor card, rectifier card controller AC drive, door drive, indication card, single phase preventer, SMPS luminous card and hall button, car and landing door shoe car guide shoe landing, CWT guid shoe landing, transformer, motor bush, hooter, FP card door hanger roller and door censor for its smooth and efficient functioning complete and all as specified and directed. Note: (i) The comprehensive maintenance shall be done through rep of OEM i.e M/S KONE as and when directed by Engineer in Charge. (ii) The above maintenance include complete maintenance of existing lift by quarterly and systematically examining, adjusting fabricating as and when required for smooth and efficient functioning of the Lift.
(iii) The comprehensive maintenance include checking and ensuring the serviceability of Machine, motors, ropes, inverter / ARD system, control parts, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock break shoes, liners, contractors, relays, push buttons, door operated VVFD, main VVFD, car door, safety device limits switch, governor, indicator etc. (iv) Unit rate of this item shall also include the calibration of lift.Check list duly signed shall be submitted by Rep of OEM. (v) The unit rate shall be deemed to include for replacement of minor spares requires for smooth functioning of elevator. (vi)Servicing of Lift shall be carried out through any OEM approved by Western Command.Contractor shall have to submit the MOU with the concerned OEM for maintenance of crane before the issue of work order .
Comprehensive maintenance and servicing of passenger elevator of capacity 10 passenger, Jhonsons Make speed limit 1.50 metre / sec equipped with microprocessor based AC variable voltage & variable frequency controller (VVFD), AC motor governor, ropes driving sheave, travelling cable, microprocessor card, rectifier card controller AC drive, door drive, indication card, single phase preventer, SMPS luminous card and hall button, car and landing door shoe car guide shoe landing, CWT guid shoe landing, transformer, motor bush, hooter, FP card door hanger roller and door censor for its smooth and efficient functioning complete and all as specified and directed. Note: (i) The comprehensive maintenance shall be done through rep of OEM i.e M/S Jhonson Lift Pvt Ltd. as and when directed by Engineer in Charge. (ii) The above maintenance include complete maintenance of existing lift by quarterly and systematically examining, adjusting fabricating as and when required for smooth and efficient functioning of the Lift.
(iii) The comprehensive maintenance include checking and ensuring the serviceability of Machine, motors, ropes, inverter / ARD system, control parts, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock break shoes, liners, contractors, relays, push buttons, door operated VVFD, main VVFD, car door, safety device limits switch, governor, indicator etc. (iv) Unit rate of this item shall also include the calibration of lift.Check list duly signed shall be submitted by Rep of OEM. (v) The unit rate shall be deemed to include for replacement of minor spares requires for smooth functioning of elevator. (vi)Servicing of Lift shall be carry out through OEM only . Contractor shall have to submit the MOU with the concerned OEM for maintenance of crane before the issue of work order .
S&f in repair 7Ah,12V batteries suitable for lifts
Repair/replacement of logic/power card suitable 8 passenger suitable for lifts as existing lift make & capacity all specifified and directed
Repair/replacement of car shoe liner(bottom type/10mm) suitable existing passenger suitable for lifts as existing lift make & capacity all specifified and directed
Repair/replacement of Metal Roller V assembly suitable existing passenger suitable for lifts as existing lift make & capacity all specifified and directed
Repair/replacement of Door Slipper assembly suitable existing passenger suitable for lifts as existing lift make & capacity all specifified and directed
Repair/replacement of phase monitor 208-480VAC suitable existing passenger suitable for lifts as existing lift make & capacity all specifified and directed
Repair/replacement of OSG assembly 1.6M/S LHD206 suitable existing passenger suitable for lifts as existing lift make & capacity all specifified and directed
Supply and laying as in repairs PVC insulated cable with Copper Conductor of size 2.5 Sqm, 4 Core 1100 volts grade heavy duty complete all as specified and directed.
Supply and laying as in repairs PVC insulated cable with Copper Conductor of size 6 Sqm, 4 Core 1100 volts grade heavy duty complete all as specified and directed.
S&F as in repairs power Contactor TP, 110 Volts coil voltage MNX-18 complete all as specified and directed.
S&F as in repairs power Contactor TP, 110 Volts coil voltage MNX-12 complete all as specified and directed.
S&F as in repairs Step down transformer having rating 440 volt to 110 volt as per existing size / rating and complete all as specified and directed.
Supply & fixing as in repairs AC Drive / variable frequency drive (VFD) / frequency convertor device system for suitable capcity of 4 KW three phase supply system with required input 3 x AC 380-480 Volt, 50 / 60 Hz and out put 3 x AC 0-480 Volt, frequency 0-400 Hz with having setting controling devices system and/or all as per existing sample / rating / model for operating/ controling of slow / high speed for all motion and other controling system etc for smooth functional of over head electric travelling crane of capacity 3 Ton and including necessary adjustment and making controlling cable connection of system and testing on load complete as as specified and directed.
All as per description of item No. 26.00 here in before but 3 HP motor of motorised door
M&L disconnecting electric connections of 3 phase motor 5 HP capcity, 415 Volts AC supply of EOT crane, taking out from the crane , dismantling / opening of motor, cutting and taking out burnt winding wire, cleaning of slots by removing dust etc and rewinding with super enamelled copper winding wire of existing gauge and class of insulations as per original manufacturers design including varnishing replacing insulation papers insulated sleeves etc, complete reassembling and reinstalling and testing on full load complete all as directed.
All as per description of item No.29 here-in-before but 7.5 HP capacity motor
All as per description of item No. 29 here-in-before but upto 3 HP capacity motor
Comprehensive maintenance of boom barrier/spike/road barrier located at main gate and Technical gate separately icluding greasing oiling,cleaning and repair/replacement of defective worn out spares complete all as specified and directed. Note: The rate shall be inclusive of all spare parts,hydraulic oil and other misc items for smooth functioning of boom barrier/spike/road barrier .
Supply, fixing and laying in any position PVC insulated PVC round Sheathed multi core industrial flexible cable conforming to IS 694:1990 copper conductor for voltage grade up to 1100 Volts grade and taking down of unserviceable cable from existing position complete of size 1.5 sqmm 16 core, complete all as specified and directed.
Supply & fix in repair Electro magnetic clutch DC working, complete set (coil body & armature plate) suitable for EOT cranes/hoist for micro speed of hoist, complete all as specified and directed.
Supply & fix in repairs flame proof pendent control box enclosure of suitable size for 3 ton EOT crane and hoist pendent control housing of 8 push button, complete all as specified and directed.
Supply & fix in repairs flame proof pendent control box enclosure of suitable size for 3 ton EOT crane and hoist pendent control housing of 10 push button, complete all as specified and directed.
Supply , programming, testing & commissioning of (VVVF) AC DRIVE 3 HP 3 Phase , 50 cycle 380/500 Volt, making electrical connections including taking down the existing unserviceable variable frequency drive from existing panel board ,after disconnecting all electric connection carefully, complete all as specified and directed.
Supply , programming, testing & commissioning of (VVVF) AC DRIVE 5 to 7.5 HP 3 Phase , 50 cycle 380/500 Volt, making electrical connections including taking down the existing unserviceable variable frequency drive from existing panel board ,after disconnecting all electric connection carefully, complete all as specified and directed.
Supply and fixing control panel wiring of existing panel with PVC copper conductor cable in PVC and testing for 3 ton EOT cranes and taking out unserviceable panel wiring, complete all as specified and directed.
Supply and fixing in repair, break liner of LT/CT hoist brake drum of 100 mm/150mm dia and 8-10 mm thickness, suitable for up to 5 ton crane complete and taking out existing unserviceable from existing position, complete all as specified and directed..
Supply and fixing in repair, MCB TPN ,40 Amp rating 'C' Series ,suitable for 415 volt 50 Hz ,AC supply, complete all as specified and directed.
All as per item No.42 above but MCB TPN, 63 Amp.
All as per item No.42 above but MCB SP, 16 Amp.
All as per item No.42 above but MCB SPN, 20 Amp.
PANWAR ELECTRICALS (BID ID -3514189)
Suman Uni Controllers (BID ID -3513981)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.55 MB
Tenderdocuments.pdf
Tender Documents • 7.96 MB
BOQ_832289.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid