Additional Chief Engineer PHED Project Region Udai
Additional Chief Engineer PHED Project Region Udaipur
RWSS of 38 Villages and 27 Other Habitations of Panchayat Samiti Bhainsrorgarh District Chittorgarh with operation and maintenance for 10 years after Defect liability period of one year on Single Point Responsibility Turnkey basis
2021_PHCJA_217320_1
ACE Proj udr 01/2020-21
Open Tender
Civil Works - Water Works
Turn-key
730 days
Bhainsrorgarh District Chittorgarh Udaipur
Please refer Tender documents.
9 documents required · 9 mandatory
₹20,000
EE PHED Project Dn Chittorgarh
Exempted
CE SP PHED Jaipur
14 Jun 2021
19 Mar 2021
23 Apr 2021
19 Mar 2021
22 Apr 2021
10 Apr 2021
6 Apr 2021
Amount
Part -A : Intake Structure
Construction of raw water intake structures as per scope of work to house 1 working and 1 standby Submerged Centrifugal LT Pump sets of duty condition of, Discharge 40.0 LPS, Head 30 m as per detailed scope of work and specification and satisfaction of EIC.
Providing installation testing commissioning of submerged centrifugal pump sets with motor (water immersed,dry air filled, class "F" insulated TEWC motor integrally mounted on vollute casing pump sets fot drinking water) 3 phase,+/- 3%,415 volt +/- 10 % along with suitable foundation installation devices and withy 10 mtr cable material of construction of impellar SS,casing(volute)CI,wearing ring SS etc complete in all respect as per specification scope of work and direction of EIC of following power rating approved by makes of Technical commitee AT INTAKE(duty condition-40 LPS /30 m head 18.50KW) one working and one stand bye
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
PART- B : WATER TREATMENT PLANT (RGF)
Design, construction, execution, testing and commissioning of Rapid Gravity filterTreatment Plant of 3.128 output MLD capacity including all relevant civil, electrical , mechanical ,instrumentation, Chlorination ( Chlorinator), scada, automization works,EFM ,Chemical House, Laboratory, office and Stores this also Includes construction of Boundary walls, steel gate,cow catchers, grating and grills at head works as per approved drawing, along with ancillary civil works as defined in scope of work.
Construction of J-2 type quarter full set as per standard drawing - 1 no.
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
PART- C : SUMP & Solar Pump Machinary for SUMP
Design, construction, execution, testing and commissioning of 3 nos. sumps ( 2 nos. of 10 KL capacity and 1 no. of 15 KL capacity ) at 03 nos. Locations as per Technical Specification and as per defined in scope of work as per direction of Engineer In charge.
10 KL Capacity
15 KL Capacity
Supply, installation, testing and commissioning of 3 nos. DC submerssible pump sets out of wich 1 no of 3 HP and 2 nos. of 1 HP with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including cable from controller to motor pumps. and MNRE approved off Grid Solar Panels of total 8 KW with inverter, meter, cable and foundation on groud Solar Power Projects with 25 years of Linear Generation warranty.The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge.
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
PART - D : PIPE LINE, Valves, Valve Chamber & VTC
DI Pipe Line
Providing, lowing laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS;8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS:5382-1985 including special (tees, bends, etc.) complete including all material , labour, hydraulic testing and commissioning including earthwork i.e., Excavation of trenches & backfilling for laying of Pipe line providing sand bedding under pipe, construction of anchors blocks, thrust blocks, cross walls, transverse blocks, pipe support structures; providing & installation of specials; clearing the site; disinfections and Dismantling of CC/BT Road cutting whereever required etc. as per technical specifications and direction of Engineer-in-charge.
100 mm dia
Providing, lowing laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS;8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS:5382-1985 including special (tees, bends, etc.) complete including all material , labour, hydraulic testing and commissioning including earthwork i.e., Excavation of trenches & backfilling for laying of Pipe line providing sand bedding under pipe, construction of anchors blocks, thrust blocks, cross walls, transverse blocks, pipe support structures; providing & installation of specials; clearing the site; disinfections and Dismantling of CC/BT Road cutting whereever required etc. as per technical specifications and direction of Engineer-in-charge.
250 mm dia
200 mm dia
150 mm dia
100 mm dia
80 mm dia
HDPE Pipe Line
Providing,lowering,laying and jointing in trenches,standard lengths HDPE ISI marked pipes of following grade and nominal diameter as per Is: 4984 :1995 (amended upto date0 with necessary joiting material like machenical connecters,i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and jointing pipes in proper position including all specials by butt fusion/ electro fusion welding method ,including all taxes (Central and local ), tranportation and frieght charges, inspection charges, loading/inloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.),satisfactory hydraulic testing, Excavation of trenches & backfilling for laying of pipes providing sand bedding under pipe, construction of anchors blocks, thrust blocks, cross walls, transverse blocks, pipe support structures; providing & installation of specials; clearing the site; disinfections and Dismantling of CC/BT Road cutting whereever required etc. complete in all respect as per the technical specification, scope of work and direction of Enginer in-charge. PE -80 PN-6
160 mm dia
140 mm dia
125 mm dia
110 mm dia
90 mm dia
75 mm dia
Manufacturing, supplying, lowering, laying and jointing in position to correct line over RCC pillar Nalla/River crossing spirally welded/ SAW /Fabricated MS pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision / amendment, including cutting wherever required, with inside linning and outside coating for following thickness and inside diamenter (bare pipe) including all taxes (Central and Local), transportation and freight charges, loading/unloading charges, including cost of labour and material, specials (Tees, bends etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge: (including construction of RCC pillar as per approved drawing)). Note : Providing and fixing of all required specials and construction of RCC pillars etc. as per drawing, design and layout are included in this item and shall not be paid separately.
250mm dia
200mm dia
150mm Dia
100mm dia
Providing and making inner cement mortar lining to MS pipes with mechanical devices in cement mortar 1:1 proportion, including cost of all materials, labour, specials, sand required , machinery,power generation, all equipments including carring of C value performance test of pipe line , including field joints at site complete as per technical specification and direction of EIC 9 mm thick for pie up to 700 mm dia
Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge:3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating
Supply laying and pushing of MS casing pipe of specified dia and thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.
300 mm Dia 8 mm thick casing pipe with protective coating.
400 mm Dia 8 mm thick casing pipe with protective coating.
500 mm Dia 8 mm thick casing pipe with protective coating.
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight (bubble tight), straight and pocket less body passage of approved make of following Class & dia complete (including jointing and jointing material) including all material, tail piece/dismantling joint, labour, earth work, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. Manually operated Resilient seated Sluice Valves of PN rating 1.0/1.6
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS, Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS: 6418, Fastners - CS, All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
50 mm dia
40 mm dia
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
EFM 50 mm
EFM 80 mm
EFM100 mm
Construction of Village transfer chamber as per approved design drawing and specification given for material of construction and completion of all works of installation of sluice valves,D joints,CI pipes,specials etc in all respect to achieve the work as given in scope of work Type for end Village
Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregateleveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse 20mm nominal size) assand : 3 graded stone aggregate 20mm nominal size) for base slab,side wall & cover slab all 125mm thick with C.I. surface box withhinged cover 100x100x75mm (deep), including cost of steel reinforcement not less than 80kg per cum CC, form work, propercuring of concrete work complete in all respect as per standardspecifications and drawings and as directed by Engineer.
60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve
90cm x 90cm x 100cm (depth) for 200/250/300 mm dia valve
Restoration/ Road repairings as per specifications for repairing of CC Roads/ Bitumen Road/ Kharanja Road/ Gravel road etc. or as per the specification given by concern department with road cutting permission. Road shall be repaired in such a way to get the repaired road surface similar to original road. work shall be done up to satisfaction of the concerned agency/department and EIC
Construction of air valve pillar for fixing of air valves as per approved drawing,complete in all respect to achieve the work as given in scope of work
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
PART E : RCC RESERVOIR
CLEAR WATER RESERVOIR
Design & Construction of clear water reservoirs of required units & capacity at following places, including its piping, fittings, Inlet piping, outlet piping ,overflow pipe washout pipe associated with valves, water Level Indicator (float type), as per approved drawing and specification complete in all respect as per the scope of work & specifications given in the tender document at the following places & sizes (Capacity shown here is the total capacity).
CWR at Bhainsrorgarh capacity 300 KL
CWR at Sripura capacity 250 KL
CWR at Dhanganmau kallan capacity 50 KL
CWR at Borav capacity 150 KL
OVER HEAD RESERVOIR
Design & Construction of Over Head Service reservoirs(Intze Tank type) as per specifications including fixing inlet; outlet; washout & overflow pipes, supply and installation of valves on inlet; outlet; washout, overflow pipes & valves in junction chamber, puddle collars, duck foot bends, pipe interconnecting the incoming & out going mains with all specials; float valve with auxiliary valve, water level indicator (float type), plinth protection works, of OHSR including Gate etc. as per approved drawing finishing, testing and commissioning complete as per the specifications and scope of work with approved drawing of following capacities:
200 KL 20 mtr staging
200 KL 18 mtr staging
150 KL 20 mtr staging
100 KL 18 mtr staging
75 KL 18 mtr staging
50 KL 18 mtr staging
Provinding, Installation,testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work,including cutting ,hoisting for following staging and capacity of Rotational Moulded Polyethlyne water storage tank in it as per indicative drawing given in the bid document.On the polythelyne tanks, there shall be provision of suitable 2.5 KW on the side of steel structure if required as per indicative drawing.Cost of solar panels in not included in this item. The structural steel shall be 120 micron hor dip galvanized iron and foundations of structure shall be in RCC with minnimum depth as 2.0 mtr (other than rocky starta). The work includeds P&F of polythelyne water storge tank (IS:12701,ISI marked,indicating the BIS license No.) of approve make with cover,Providing & fixing 50 mm dia ISI marked GI class B pipe for inlet,outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM rate valves at inlet and outlet pipe including making connection etc. complete as per drawing ,technical specification and direction of Engineer in charge .The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank ground and up to 2.0 mtr away from foundations and over flow pipe is to be interconnected in distributions pipe line .Wash out pipe shall be taken up to as suitable point minimmum 5.0 mtr away from tank .Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled
.5000 Ltr X2 Nos. PE water tank,staging 10 meter.
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
PART F : PUMP STATION : CIVIL WORK
Design and Construction of pump house building with structures required for suction manifold including providing pump floor area; switch-gear or panel area; control room; maintenance bay/ loading – unloading bay; Duty room, office area, lavatories, , foundations for pumps, support structures for delivery pipes/valves, cable trenches, thurst blocks, pedestals, valve chambers, cable trenches, parking area, water supply, sanitary, lighting systems, septic tanks, Providing and Installation of Drain Pump set of with GI pipe and all required accessories to drain out water from pump floor. Two numbers at each pumping station and all finishing work to complete the building,Campus development works for following headworks which includes External Lighting, Horticulture, Construction of Cement Concrete Road, Construction of Surface Drainge complete in all respect as per the given scope of work with approved drawing and specifications. This item include all related civil work like valve chamber, meter chamber etc.
At Bhainsrorgarh H/W 150 SQM
At Sripura H/W 150 SQM
At Dhangan mau kallan H/W 150 SQM
At Borav H/W 180 SQM
Construction of J-2 type quarter as per standard drawing toal 3 nos.at Sripura ,Dhanganmau kallan and Borav H/Ws
Construction of office building 1 nos as per approved drawings at COR complete including foundation
Construction of office building 1 nos as per approved drawings at UDR complete on existing office building (to be constructed on first floor)
Construction of new Boundary wall, steel gate ,cow catcher,grating and grills at head works as per approved drawing, scope of work & Specification complete in all respect
At Various H/Ws and Reservoirs
construction of cement concrete Approach Road 4.5 mtr wide and 150 mm thick with 50cm wide brick edge flooring on both side of road with culvert for water streams where ever required as per specification
At various H/Ws
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
PART G : PUMP STATION : MECHANICAL
Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete, flanged jointing wherever required including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer.
At Bhainsrorgah
At Sripura
At Dhanganmaukallan
At Borav
At Intake
Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (suitable for sluice valves etc.) , stain less steell expansion bellows as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
At Bhainsrorgah
At Sripura
At Dhanganmaukallan
At Borav
At Intake
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.
250mm Dia
200mm Dia
150 mm dia
100 mm dia
Providing, lowering, laying, aligning, fixing in position CI D/F short body pattern type butterfly valves of approved make of following Pressure rating & dia complete, conforming to IS13095/1991 (amended upto date) and of following specifications: Body, disc and end cover of Grey cast iron of IS:210/ FG200, Face to face dimensions as per IS: 13095 & Drilled as per IS:1538. Shaft of SS- AISI- 304/316 & shaft bearings- bronze/Teflon with EPDM/NBR "O "ring seal, generally synthetic rubber faced ring secured on disc by retaining ring with SS steel screw stub, Seating ring/ Seal retaining ring of SS- AISI- 304/316 Seat of EPDM/ Neoprene/ NBR, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. 2 coats of red oxide conforming to IS:5660 on drained, cleaned & prepared unmachined surface and rust preventive coat on machined and flanged surface and two coats of paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specifications and as per direction of Engineer in charge.
250mm Dia
200mm Dia
150 mm dia ( With lever operated)
100 mm dia ( With lever operated)
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
150 mm dia
100 mm dia
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O" ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.
250 mm dia
200 mm dia
150mm Dia
100mm Dia
Supply, delivery at site with necessary packing, receiving, unloading,shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casting pumps with motor, CI casing and casingring, SS 316 impeller, SS 410 Shaft and shaft sleeve, couplingguard, common base plate, foundation bolts etc. complete with all respect as per specifications
Bhaisrordgarh PS to CWR Sripura
Discharge 28 LPS and head 60 mtr
Sripura PS to Dhanmau kallan borav side
Discharge 22 LPS and head 65.00 mtr
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 operating at sync. speed 2900 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee.
Bhaisrorgarh PS
Sripura PS
Dhanganmau kallan PS
Borav PS
Electrically opeared overhead hoist (EOH) single bridge girder carrying two wheels with chain pulley block load chain, handchain encased gears, trolley trolley track, wheels, swivel type lifting hook for 5 MT capacity, 6 m lift and 7 m SPAN
Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (including CI/DI fittings) and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification and as per direction of Engineer.
EMF250 mm
EMF200 mm
EMF150 mm
EMF100 mm
EMF80 mm
Supply, Installation, Commissioning & testing of Continous type Electrochlorinator including all required pipe fitting, accessories, valves etc, Brine Tank (HDPE material) of required capacity , level & Temprature sensors, pumps, Rotameter, Electrolyzer of required capacity, Hypo tank (HDPE Material), Blower, acid tank & pump, DC rectifier cum Control Panel and all required power & control cables complete
Sripura PS- 200 gm/hr
Dhanganmau kallan PS-200 gm/hr
Borav PS- 150 gm/hr
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
PART H : PUMPING STATION : ELECTRICAL WORKS
Supply, Installation, Testing and Commissiong of LV switchboard, LTMCC with panel housing motor starter Relay MSB/MSSBs bus-bar from Switchyard up to Panels With soft Starter for each pump, capacitor control panels housing power factor control system panel/capacitors (APFC Panel), Including installation of local push button at each pump and other accessaries including all internal cabling and cable/bus -bar from swith yard up to panel as per approved SLD at the following location.
At Bhainsrorgarh Intake
At Bhainsrorgarh Pump House
At Sripura Pump Houe
At Dhanganmau kallan Pump House
At Borav Pump House
Providing, laying, testing & commissioning of Complete cabling system with LV power & control cables, cable trays, route marker, steel structure for cable trench, MS pipes and accessories at the following location
At Bhainsrorgarh Intake
At Bhainsrorgarh Pump House
At Sripura Pump Houe
At Dhanganmau kallan Pump House
At Borav Pump House
Supply, Installation, Testing & commissioning of Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories at the following location.
At Bhainsrorgarh Intake
At Bhainsrorgarh Pump House
At Sripura Pump Houe
At Dhanganmau kallan Pump House
At Borav Pump House
Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard.The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Engineer Incharge
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
PART J : Tools and Plants
Provision for Tools and Plants
PART K : Fuctional Household tap Connections
providing Fuctional Household tap Connections including Road Cuting, Earth work And restoration per technical specification and scope of work as per direction of Engineer In Charge.
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis (See Clause 17 : Preamble to Price Schedule)
INSTRUMENTATION & SCADA
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application : Principle : Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4-20mA / Display: Integral display for programming and Display Reading / IP 66
Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per Technical specification and as per direction of Engineer
0 to 4.0 / 0 to 6.0 / 0 to 10.0 kg/cm²
Supply, Installation, Testing, Commissioning of PLC/SCADA system including all hardwares,softwares,all accessorings for complete water supply project / system configuration alongwith SCADA for Master Control Centre for monitering the water supply for 38 MH and 27 OH including pressure transmitter at each pump set etc. as per specifications complete in all respect.
All other items, accessories, work not specified but essentially required to complete of the work on turn key basis ( See Clause 17 : Premble to Price Schedule)
SURGE PROTECTION SYSTEM
SITC of Material & Equipment including related civil works for Surge protection System as per Scope of Work & specification and other items & accessories not specified but required to complete the work on turn key basis.
SUM OF CAPITAL WORKS
PART L : OPERATION & MAINTENANCE
Cost for Basic Service Charges, Administration and Management, Running of Office, Staff Quarters, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, salts for producing chlorine, chemicals,(except PAC & Chlorine) Consumables, Spare Parts (if the spare parts supplied to PHED are used in emergency) as per Scope of Work & terms & conditions of contract for 10 year after defect laibility period of one year.
O&M of entire system for Defect laibility period of one year (free of cost)
O&M of entire system for 1st year of O&M period
O&M of entire system for 2nd year of O&M period
O&M of entire system for 3rd year of O&M period
O&M of entire system for 4rth year of O&M period
O&M of entire system for 5th year of O&M period
O&M of entire system for 6th year of O&M period
O&M of entire system for 7th year of O&M period
O&M of entire system for 8th year of O&M period
O&M of entire system for 9th year of O&M period
O&M of entire system for 10th year of O&M period
MAHESHWARI CONTRACTORS PVT.LTD.
MULTIURBAN INFRA SERVICES PVT.LTD.
M/S Jagdish Prasad Agarwal
lahotybuildcon
OFFSHORE INFRASTRUCTURES LTD
Rean Watertech Pvt. Ltd.
DARA ENGINEERING AND INFRASTRUCTURES PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .