Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.3 LAccepted-AOC | 1 | Accepted-AOC AOC | |
| 2 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC |
| Sl No | Description | Qty | Unit | rajarethinam subramanian L1 |
|---|---|---|---|---|
| 1.00 | Earth work excavation for foundation, etc., in all soil sand sub- soils and to full depth as may be directed except in hard rock requiring blasting inclusive of shoring, shuttering, bailing out water wherever necessary refilling the foundation with excavated earth other than sandy soil in layers of not more than 15 cm thick well rammed and depositing the surplus earth with in the compound in place shown by the departmental officers within an initial lead and lift and clearing and levelling the site etc.,complete | 7.45 | M3 | 1,937 ₹1,937 Lowest |
| 2.00 | Supplying and filling in foundation and basement with good Stone Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specfication. | 1.8 | M3 | 1,521 ₹1,521 Lowest |
| 3.00 | Cement Conceret 1:4:8 (One Cement four M-sand and eight aggregate) using 40mm hard broken granite stone jelly for foundation including dewatering and wherever necessary laying in layers of 15cm thick and consolidated and curing complying with standard specification and as directed by the departmental officers etc., complete | 1.8 | M3 | 12,042 ₹12,042 Lowest |
| 4.00 | Brickwork in Cement Mortor 1:5 (One cement five M-sand) mix using country burnt bricks of standard size 8 3/4"x4 1/4"x2 1/4" including cost and conveyance of all materials and labour etc complete as per standard specification | 7.35 | M3 | 58,800 ₹58,800 Lowest |
| 5.00 | Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86. | 7.35 | M3 | - |
| 6.00 | With Strutting | 7.45 | M2 | 5,289.5 ₹5,289.5 Lowest |
| 7.00 | Columns | 20.85 | M2 | 12,927 ₹12,927 Lowest |
| 8.00 | Slabs and Beams | 17.55 | M2 | 16,409.25 ₹16,409.25 Lowest |
| 9.00 | Reinforced Cement Concrete 1:1½:3 Mix (One part cement, one and half part sand and three part of aggregate)using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing but excluding cost of reinforcement etc. Complete with std. Specifications. TNDSS NO: 30 V, VI (S3), VII-3. | 6.15 | M3 | 57,656.25 ₹57,656.25 Lowest |
| 10.00 | Supplying and fabrication of steel and placing in position of TMT steel rods for RCC works as per design given including cost of steel and GI binding wire in all floors etc., complete complying with standard specification in TNDSS NO:97 V,VI (S6) VII (S6), VII-3. | 492 | Kg | 45,510 ₹45,510 Lowest |
Tender Value
₹4 L
EMD Value
₹4,000
Closing Date
17 Sept 2025, 3:30 pmClosed
Executive Offier Peralam Townpanchayat
Executive Offier Peralam Townpanchayat
Construction Of Urnal At Theater Opposite In Peralam Town Panchayat.
2025_DTP_603487_1
52/2025
Open Tender
Civil Works - Buildings
Works
180 days
Work
Class II
2 documents required · 2 mandatory
₹0
₹4,000
Yes
Executive Offier Peralam Townpanchayat
13 Oct 2026
12 Sept 2025
17 Sept 2025
12 Sept 2025
17 Sept 2025
12 Sept 2025
12 Sept 2025
Earth work excavation for foundation, etc., in all soil sand sub- soils and to full depth as may be directed except in hard rock requiring blasting inclusive of shoring, shuttering, bailing out water wherever necessary refilling the foundation with excavated earth other than sandy soil in layers of not more than 15 cm thick well rammed and depositing the surplus earth with in the compound in place shown by the departmental officers within an initial lead and lift and clearing and levelling the site etc.,complete
Supplying and filling in foundation and basement with good Stone Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specfication.
Cement Conceret 1:4:8 (One Cement four M-sand and eight aggregate) using 40mm hard broken granite stone jelly for foundation including dewatering and wherever necessary laying in layers of 15cm thick and consolidated and curing complying with standard specification and as directed by the departmental officers etc., complete
Brickwork in Cement Mortor 1:5 (One cement five M-sand) mix using country burnt bricks of standard size 8 3/4"x4 1/4"x2 1/4" including cost and conveyance of all materials and labour etc complete as per standard specification
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86.
With Strutting
Columns
Slabs and Beams
Reinforced Cement Concrete 1:1½:3 Mix (One part cement, one and half part sand and three part of aggregate)using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing but excluding cost of reinforcement etc. Complete with std. Specifications. TNDSS NO: 30 V, VI (S3), VII-3.
Supplying and fabrication of steel and placing in position of TMT steel rods for RCC works as per design given including cost of steel and GI binding wire in all floors etc., complete complying with standard specification in TNDSS NO:97 V,VI (S6) VII (S6), VII-3.
Plastering with cement mortar 1:5 ;12 mm thick in all floors etc., complete complying with standard specifications (S.I.306)
Plastering with cement mortar 1:3 ;12 mm thick in all floors etc., complete complying with standard specifications (S.I.306)
Flooring with ceramic tiles of 305x305x6 mm size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of 300x200x6 mm sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Painting the newly plastered wall surface with two coats of cement paint of approved quality and colour over one coat of cement primer including cleaning the surface etc complete as per standard specification.
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling and switch drop portion PVC rigid pipe concealed in wall with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate Suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling and switch drop portion PVC rigid pipe concealed in wall with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate Suitable colour for Concealed PVC Plug Point
Supply and fixing of single box type 4'20W LED fitting with LED (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting
Manufacturing, supplying and fixing of Steel doors with following specification. MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 G CR Sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter. 300mm length of hinges 2 Nos, for shtter is provided. 6 Nos. of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. at the top provided. 250x16mm size of Two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear sideof the door at an appropriate place and 1 No. of M.S. handle of heavy duty. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete. (Single Leaf)
Supply, Delivery and fixing of PVC Pipes and specials etc., complete as per standard specifications
110mm PVC Pipe
75mm PVC Pipe
32mm PVC Pipe
25mm PVC Pipe
110mm PVC Elbow
110mm PVC Tee
110mm PVC Elbow With Door
110mm PVC Tee With Door
32mm PVC Elbow
32mm PVC Tee
32mm PVC Coupler
25mm PVC Elbow
25mm PVC Tee
25mm PVC Coupler
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .