Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.4 LAccepted-AOC VILLAGE CHANDANDIH PO PS LATEHAR DISTRICT LATEHAR JHARKHAND 829206 | LATEHAR | JHARKHAND | 829206 | L1 | Accepted-AOC L-1 | |
| 2 | L2₹73.8 L+₹3.4 L (4.77%)Rejected-Finance 1264 86 TRI NAGAR SHANTI NAGAR NORTH WEST DELHI DELHI 110035 | NORTH WEST DELHI | DELHI | 110035 | L2 | Rejected-Finance L2 | |
| 3 | L3₹79.1 L+₹8.7 L (12.4%)Rejected-Finance JHARKHAND | LOHARDAGA | JHARKHAND | 835302 | L3 | Rejected-Finance L3 | |
| 4 | L4₹79.9 L+₹9.5 L (13.5%)Rejected-Finance AT JYOTI NAGAR BAIRIYA CHOWK SUDNA DALTONGANJ PALAMU 822102 | PALAMU | JHARKHAND | 822102 | L4 | Rejected-Finance L4 | |
| 5 | L5₹81.8 L+₹11.4 L (16.2%)Rejected-Finance 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | MOHAMMAD IMRAN L6 | S K Enterprises L5 | M/S U.K. CONSTRUCTION L1 | SUNITA DEVI L3 | RAMESH KUMAR L4 | SHANTI TRADERS L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I | 172.18 | cu.m | 154.6 ₹26,619.03 | 152.94 ₹26,333.21 | 131.97 ₹22,722.59 Lowest | 147.92 ₹25,468.87 | 149.74 ₹25,782.23 | 138.88 ₹23,912.36 |
| 2.00 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and | 209.6 | cu.m | 51.07 ₹10,704.27 | 50.53 ₹10,591.09 | 43.6 ₹9,138.56 Lowest | 48.87 ₹10,243.15 | 49.47 ₹10,368.91 | 45.88 ₹9,616.45 |
| 3.00 | Providing coarse clean SAND FILLING in foundation trenches or plinth including ramming & watering in layers not exceeding | 122.88 | cu.m | 544.65 ₹66,926.59 | 538.81 ₹66,208.97 | 464.95 ₹57,133.06 Lowest | 521.13 ₹64,036.45 | 527.55 ₹64,825.34 | 489.29 ₹60,123.96 |
| 4.00 | Providing designation 75B one BRICK FLAT SOILING joint filled with local sand including cost of watering taxes royalty all complete as per | 164.51 | sq.m | 305.2 ₹50,208.45 | 301.93 ₹49,670.5 | 260.54 ₹42,861.44 Lowest | 292.02 ₹48,040.21 | 295.62 ₹48,632.45 | 274.18 ₹45,105.35 |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) | 70.82 | cu.m | 4,584.14 ₹3,24,648.79 | 4,535.02 ₹3,21,170.12 | 3,913.32 ₹2,77,141.32 Lowest | 4,386.17 ₹3,10,628.56 | 4,440.25 ₹3,14,458.51 | 4,118.24 ₹2,91,653.76 |
| 6.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | 38.63 | cu.m | 4,820.91 ₹1,86,231.75 | 4,769.25 ₹1,84,236.13 | 4,115.44 ₹1,58,979.45 Lowest | 4,612.71 ₹1,78,188.99 | 4,669.59 ₹1,80,386.26 | 4,330.94 ₹1,67,304.21 |
| 7.00 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete | 131.82 | M2 | 179.7 ₹23,688.05 | 177.77 ₹23,433.64 | 153.4 ₹20,221.19 Lowest | 171.94 ₹22,665.13 | 174.06 ₹22,944.59 | 161.44 ₹21,281.02 |
| 8.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | 20.63 | cu.m | 4,820.91 ₹99,455.37 | 4,769.25 ₹98,389.63 | 4,115.44 ₹84,901.53 Lowest | 4,612.71 ₹95,160.21 | 4,669.59 ₹96,333.64 | 4,330.94 ₹89,347.29 |
| 9.00 | Colm--Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete | 225.84 | M2 | 429.96 ₹97,102.17 | 425.36 ₹96,063.3 | 367.05 ₹82,894.57 Lowest | 411.4 ₹92,910.58 | 416.47 ₹94,055.58 | 386.27 ₹87,235.22 |
| 10.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | 28.17 | M3 | 4,820.91 ₹1,35,805.03 | 4,769.25 ₹1,34,349.77 | 4,115.44 ₹1,15,931.94 Lowest | 4,612.71 ₹1,29,940.04 | 4,669.59 ₹1,31,542.35 | 4,330.94 ₹1,22,002.58 |
Tender Value
₹89.5 L
EMD Value
₹1.8 L
Closing Date
21 Oct 2024, 11:00 amClosed
EE, BCD Building Division Latehar
EE, BCD Building Division Latehar
CONSTRUCTION OF QUARANTINE CENTER FOR COW / GOAT SHED JALTA - LATEHAR AT BLOCK - LATEHAR , DIST- LATEHAR , JHARKHAND
2024_BCD_95667_1
20/2024-25/EE/BCD/LATEHAR
Open Tender
Civil Works - Buildings
Works
270 days
Latehar
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.8 L
Yes
29 Jan 2026
10 Oct 2024
22 Oct 2024
10 Oct 2024
21 Oct 2024
10 Oct 2024
Amount
Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and
Providing coarse clean SAND FILLING in foundation trenches or plinth including ramming & watering in layers not exceeding
Providing designation 75B one BRICK FLAT SOILING joint filled with local sand including cost of watering taxes royalty all complete as per
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Colm--Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforcement for RCC work including straightening, cutting, bending, placing in position and bonding all complete.
TMT-500 8mm dia
TMT-500 10mm dia
TMT-500 12mm dia
TMT-500 16mm dia
TMT-500 20mm dia
Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
Providing designation 75 B brick work in C.M (1:6) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials , scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
proved and laying 6mm .precast white glazed tiles in wall over 12mm .cement morter (2:3)and jointend with grey cement slurry flush pointed with white cement including rubbing ,polisingand cost of curing taxes ,and royalty all complete as per building specification and direction of
with "A"grade white 15x15cm .tiles
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 6 mm thick cement plaster (1:4) in Celling with clean coarse sand of F.M. 1.5 including screening, curing with all lead and
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I..
Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately),21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Bend - 110mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Providing 1.5 mm cement punning including curring, carrage of water with all leads and lifts as per building specification and direction of E/I.
Carrage of materials
Sand av lead 10 K M
Chipes av lead 20 K M
Bricks av lead 8 K M
Metal 10Km
providing and placing on terrace (at all floor levels) polyethylene water storage tank. ISI :12701 marked, with cover and suitable licking arrangement making necessary holes for inlet, outlet and overflow pipe but without fitting and the base support for tank.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing male ended 15 mm dia brass bib cock of approved quality (wt not less than 350 gms) with extra socket all complete as per specification and direction of E/l.
Providing and fixing G.M. non return valve Horizontal / vertical type of approved quality as per specification and direction of E/l.
(A) Horizontal (2) 20 mm dia
(B) Vertical (1)15 mm dia
Wiring for light point/ fan point/ exhust fan point/call bell point with 1.5 sq.mm FR PVC Insulated copper conductor single core cable in surface / recessed PVC conduict, with modular type switch, Modular plate, suitable size G.I.box as required.
Group "C"
Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.
Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
Power Plug Wiring in PVC conduit (2x4 sq. mm): Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2x2.5 Sqmm + 1x2.5 sqmm earth wire
2x4 Sqmm + 1x4 sqmm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/ recess including cutting the wall and making good the same as required.
S/F s.p. MCB DB:supplying and fixing following way single pole neutral sheet, MCBdistribution board,240 volts,on surface/recess,completewith tinned copper busbar,neutral busbar,earth bar,din bar, detachable gland plate,interconnection,phosphatized and powder painted including earthing etc asrequierd.(But without MCB/RCCB/lsolator)
6 way Double door
S/F 'C' series SP MCB: Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.
6/32A Single Pole
S/F Ceiling Rose: Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required.
S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
S/F Batten Holder: Supplying and fixing batten/angle holder including connection etc. as required.
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Extra Salt & Charcoal for Copper Earth Plate Elecrode:- Providing and fixing salt and charcoal or cock for copper earth plate elecrode complete etc as required.
Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required.
S/F Busbar chamber:- providing and fixing following capacity busbar chamber with 4strips of suitable size made copper heavy,duty,complete with allaccessories including connection,earthing the body,etc as reqired. 2.5.1 - 100 Amp.
S/F sheet metal ON/OFF-load changcover:- providing and fixing following capacity 2 pole/4 pole ON/OFF-load changeover switches withside handle opreation,in sheet enclosure in existing metal board including drilling holes in metal board,making connection,earthing the board etc.as required.
63amps,2pole
MV Cable:- Supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS:7098 armoured, served, sheathed, 1100V grade with Termination and Laying of cable.
4 Core 16 Sq mm (For main panel)
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
15/16 watt LED Bulb
S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required
90/100 W LED Flood light
Supply of Metal Exhaust Fan 12"(300mm): Supply of 12"(300mm), 230V AC metal exhaust fan in the existing opening.
Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required.
1200mm (48") Ceiling Fan
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M upto 150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supplying Full automatic star selta starter to operate induction motor working on 415v 3phase 50hz with no coil. Over load element , On _OFF push buttom with necessary materials and connection to Supply etc complete starter with original sheel steel encloser as per 3914. F.A.S.D starter upto 5 H.P
3 core PVC insulated PVC sheathed copper conductor flat submersible cable. Supplying , Flat flexible submersible cable with ,copper conductor , PVC insulated and PVC sheathed as IS:7098-- 3 Core 4 Sq mm
Supply fitting and fixing GI pipe 50 mm Dia (TATA or equivalent make) Medium Quaility as per IS:1239 ( part 01 ) 2004
Add 18 % GST (in Basic Rate must fill 12)
Add 1% Labour Cess (in Basic Rate must fill 1)
SHANTI TRADERS (BID ID -636798)
SUNITA DEVI (BID ID -636845)
RAMESH KUMAR (BID ID -636763)
S K Enterprises (BID ID -636696)
MOHAMMAD IMRAN (BID ID -636674)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .