Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹9.5 L+₹1.4 L (17.6%)Rejected-Finance SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹10.0 L+₹1.9 L (23.9%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance 3rd Lowest | |
| 4 | Rejected-Technical 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | - | Rejected-Technical Insufficient Documents | |
| 5 | Rejected-Technical | - | Rejected-Technical Insufficient Documents |
Tender Value
Refer Docs
EMD Value
₹22,000
Closing Date
4 Nov 2019, 5:00 pmClosed
EE KED
New Building Erstwhile CGA Office 1st Floor Writers Buildings Kolkata 700 001
Electrical renovation work including installation of Air Conditioning machine at Block 3 3rd Floor under Writers Buildings Electrical Section No II IV under Writers Buildings Electrical Sub Division PWD Air-Conditioning work
2019_WBPWD_248927_1
WBPWD/EE-KED/e-NIQ-11 (3rd Call)/2019-20
Open Tender
A/C ORG
Item Rate
15 days
Writer Buildings campus
Please refer Tender documents.
4 documents required · 4 mandatory
₹22,000
Yes
17 Aug 2022
18 Oct 2019
7 Nov 2019
18 Oct 2019
4 Nov 2019
20 Oct 2019
Amount
Supply , installation, testing & commissioning of Microprocessor based , medium static air cooled (2.8TR/3.0TR) Ceiling Suspended Ductable type Split Air Conditioner with R-410A gas having normal cooling capacity of minimum 34120 BTU/Hr with single/multiple scroll/Rotary compressor, Power Input: 3.85 KW(max) condenser make as per OEM standard, noise Level not more than 50 dB, Air Flow 1750 m3/HR(min) suitable for operation on 415 Volt.+-5, 50 hz-3 Ph. AC Supply.(Make: MITSUBISHI HEAVY INDUSTRIES/ O General/ MITSHUBISHI ELECTRIC).
Supply of /1.5/1.6 Ton Split Air Conditioner fitted with Rotary Compressor: Cooling capacity nominal (K.Cal/Hr): 5500; Cooling Cap (Min) Guaranteed (K.Cal/Hr): 4275; Min Room Discharge Air Flow (Cu.m/h): 700; R410a Gas; Star Rating: 03 Make: Mitsubishi Heavy(SRK20CSS-S6/A) / O.General
Installation Charges for 1.5 TR split type AC machines including hanging of Indoor unit and fixing of Outdoor unit along with Outdoor Iron bracket.
Supply and fixing of electric cable 3 core 2.5 sq. mm, Copper pipe 1/4” for discharge, 5/8” for suction,Nitrial rubber insulation for 1/4” suction line & 5/8” discharge line and PVC drain pipe for water drainage for 1.5 TR Split machine.
REFRIGERANT PIPING For DX machine Installation & commissioning of hard copper refrigerant piping, complete with fittings Elbows, Bends, supporting arrangement on walls for Ductable Split AC. Liquid Line hard Cu pipe maximum thickness 1.15 mm following Dia. [Make Royku/Totaline/ Mandeep] with 13 mm nitle tube insulation .[Make Aeroflex/Acoflex]
9.52 mm dia (3TR DX machine)
GAS LINE for DX machine: Hard cu pipe minimum thickness 1.15 mm. Following Dia [Make Royku/Totaline/Mandeep} with 13mm thick nitrile tube insulation [Make Aroflex/Acoflex]
15.88 mm Dia (for 3 TR DX machine)
DRAIN PIPING: Supply & laying drain Water piping work out of UPVC/HDPE hard pipes (60 schedule) Make HB/Supreme/Oriplast) incl. Fittings, accessories bends , elbows, tees,flanges tapings, etc insulated with 9mm. Thick nitrile rubber tube insulation.
25 mm Dia
19 mm Dia
REFRIGERANT FOR DX MACHINE: Supply & charging Refrigerant - R410 A
Febrication of iron Bracket/ platform which is made with 3nos. 50X50X6mm (10mtr) as main & side support and 8mtr of 50X6mm iron flat for making platform, it should have the facility to install one outdoor unit of split AC machine at middle of the bracket and sufficent space should be maintained both side of the each outdoor unit for maintenance work also have suitable angle support between wall & bracket. It should have a safety ring gaurdd upto height 3ft from base frame & made by 40X40X6 and painting the same as per direction of EIC.
RAMKRISHNA ELECTRONICS
MILLENNIUM AIRCON
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .