Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC BAZARPURA NOWROZABAD MADHYA PRADESH 484555 DIST UMARIA M P | NOWROZABAD | UMARIA | MADHYA PRADESH | 484555 | ₹18.3 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹2.0 LRejected-Finance ETTA BHATTA MAINROAD SURAJPUR BHATGAON SURAJPUR CHHATTISGARH | DURG | CHHATTISGARH | 490001 | ₹2.0 L | L2 | Rejected-Finance Rejected being L1 |
| Sl No | Description | Qty | Unit | SURESH ELECTRICALS L1 | M/S UMASHREE ENGINEERING L2 |
|---|---|---|---|---|---|
| 1.00Electrical AMC for the elctrical repair and maintenance of Noworozabad colony and Noworozabad Sub Area Office of Johilla Area. | |||||
| 1.10 | Rewiring for light point/ fan point/ exhaust point / call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Group A) | 226 | Point | 125 ₹28,250 | 125 ₹28,250 |
| 1.20 | Rewiring for light point/ fan point/ exhaust point / call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Group B) | 171 | Point | 125 ₹21,375 | 120 ₹20,520 |
| 1.30 | Rewiring for light point/ fan point/ exhaust point / call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Group C) | 119 | point | 130 ₹15,470 | 140 ₹16,660 |
| 1.40 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 1.5 sq. mm. + 1 X 1.5 sq. mm. earth wire) | 885 | Mtr. | 150 ₹1.3 L | 155 ₹1.4 L |
| 1.50 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire) | 435 | Mtr. | 120 ₹52,200 | 180 ₹78,300 |
| 1.60 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 2.1.1 32 A TP&N | 72 | Each | 2,800 ₹2.0 L | 650 ₹46,800 |
| 1.70 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63A TP&N | 24 | Each | 75 ₹1,800 | 900 ₹21,600 |
| 1.80 | Supplying and fixing following piano type socket on the existing switch box/ cover including connections etc. as required pin 5/6 amp socket outlet | 124 | Each | 100 ₹12,400 | 120 ₹14,880 |
| 1.90 | Supplying and fixing following piano type socket on the existing switch box/ cover including connections etc. as required 6 pin 15/16 amp socket outlet | 65 | Each | 120 ₹7,800 | 180 ₹11,700 |
Tender Value
₹26.4 L
EMD Value
₹33,100
Closing Date
25 Apr 2025, 6:55 pmClosed
Lokesh Kumar Malav
SO EnM Office Johilla Area
Annual Maintenance Contract for the electrical repair and maintenance of Nowrozabad colony Noworozabad Sub Area Office Johilla Pump House and other miscellaneous places under Nowrozabad sub area of Johilla Area
2025_SECL_334050_1
SECL/JHL/SO(EM)/25-26/ ET/252605 dt 11.04.2025
Open Tender
Electrical and Maintenance Works
365 days
SO EnM Office Johilla Area
5 documents required · 5 mandatory
₹33,100
19 Feb 2026
11 Apr 2025
26 Apr 2025
11 Apr 2025
25 Apr 2025
11 Apr 2025
11 Apr 2025 - 21 Apr 2025
Amount
Electrical AMC for the elctrical repair and maintenance of Noworozabad colony and Noworozabad Sub Area Office of Johilla Area.
Rewiring for light point/ fan point/ exhaust point / call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Group A)
Rewiring for light point/ fan point/ exhaust point / call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Group B)
Rewiring for light point/ fan point/ exhaust point / call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Group C)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 1.5 sq. mm. + 1 X 1.5 sq. mm. earth wire)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 2.1.1 32 A TP&N
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63A TP&N
Supplying and fixing following piano type socket on the existing switch box/ cover including connections etc. as required pin 5/6 amp socket outlet
Supplying and fixing following piano type socket on the existing switch box/ cover including connections etc. as required 6 pin 15/16 amp socket outlet
Supplying and fixing following piano type switch on the existing switch box/ cover including connections etc. as required 5/6 amps switch
Supplying and fixing following piano type switch on the existing switch box/ cover including connections etc. as required 15/16 amp switch
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module
Supplying and Fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required
Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DP complete with connections, testing and commissioning etc. as required - 63 A
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V on surface / recess, complete with tinned copper bus bar, neytral bus bar, earth bar, din bar, interconnection, powder painted including eathing etc. as required ( But without MCB/RCCB/Isolator) 6 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415V, 10KA, "C" curve, miniature circuit breaker suitable for inductive load off following poles in the existing MCB DB complete connection, testing and commissioning etc. as required - Double Pole
Complete supplying and fixing XLPE insulated power cabel armoured 1.1 KV grade 2 core with aluminium conductor 2 core 16 sq. mm.
"Supplying of prestressed cementconcrete (PCC) pole conforming to IS: 785 at worksite including required transportation PCC pole 10 mtrs long 140 KG (1.01)" .
Errection of RCC/PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with inculding excavation and refilling etc as required. Above 8 meter and upto 11 meter
Supplying and erection of stay complete(gaivanished) with 19/20 mm dia X 1.8 meters long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thimble, stay clamps, bow tightiner, 7/3.15 mm dia G.I. stay wire and strain insulator etc. in cement concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggegate 40 mm nominal size) foundation inculding excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 401 mm X 6 mm(7.14 Kg per meter) cross arm 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc.(as per drawing) and painting with primer and finished paint as required
Erection of angle iron/ channel iron cross arm on wood/RCC/PCC/steel tublar/rail pole etc. as required.
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm ), G.I. bolts, nuts and washers, coach screws etc. as required
Supplying and erection of 100 mm X 65 mm pin insulator complete with G.I. spindle and nuts etc. as required.
Ercetion of G.I. wire No. 8 SWG including binding etc. as required.
Erection of cradle guard as required
Supplying of channel iron 75 mm X 40 mm X 6 mm ( 7.14 kg per meter) cross arm for 2 wire overhead line conductor complete with clamp, bolt, nut and washer for guarding including drilling holes for insulators pins, bolts and nuts etc & painting with primerand finish paint as required.
Erection of angle iron/ channel iron cross arm for guarding on wood/RCC/ PCC/ steel tubular rail pole etc. as required.
Dismentaling of Overhead lines comprising of copper/aluminium over head conductor G.I. wire, cross arms, insulators etc. as required.
Dismentaling of pole/street light standard/ strut embedded in brick ballast foundation etc.as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm ( 7.14 kg per meter) pole top bracket/ cross arm for single 11 KV overhead line conductor complete with 50 mm X 6 mm flat iron clamp, bolt, nut and washer including drilling holes for insulators pins, bolts and nuts etc & painting with primer and finish paint as required
Supplying of channel iron 75 mm X 40 mm X 6 mm ( 7.14 kg per meter) V shape cross arm for two 11 KV overhead line conductor complete with 50 mm X 6 mm flat iron clamp, bolt, nut and washer including drilling holes for insulators pins, bolts and nuts etc & painting with primer and finish paint as required
Erection of pole top/ staright two wire/ V shape two wire, angle iron/ channel iron cross arm on steel, tubular/ rail/PCC pole for 11/22/33 as required.
supplying of two lengths of channel iron 75mmx40mmx6mm (7.14 kg per metre) double pole cross arm for three wire 11 kv oh line complete with through bolt and nut for clamping to poles 50mm x 6mm M, S. flats welded on one side to the channel iron and with nut bolts and nut on other vside for tying cross arm together including drilling holes for insulator pin, bolt and nut and washer etc and painting with primar and finish paint as required
Erection of double pole 3 wire cross arm for 11KV/22KV/33KV overhead lines as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc as required
Supplying and erection of 11 KV disc insulator for 11 KV overhead line with galvanised insulator fitting, ball and socket type and complete with glavanised strain clamp, bolt, nut, washer etc as required
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding as required for 3 conductor
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accssories and providing masanory enclosure with cover plate have locking arrangement and water pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
Supplying and erection of three piece nonlinear resistor type lighting arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV(rms) with a nominal discharge current rating of 5 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required,
Supplying installing testing and commissioning of outdoor H.T. AB switch assembly set gang operated with brass contact parts, including required HI pipe operating rod, handle & locking arrangement on ON-OFF position confirming to IS complete with required material and installing on exixting DP structure to complete the job as required as per specification (set of 3 nos.) 11 KV, 400 Amp
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 70 sq. mm.
Supplying and making straight through cable jointing kit complete with all accessories including ferrules suitable for following sizeof 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 70 sq. mm.
Providing and fixing of 33 KV GOAB switch with all accessories
Supplying and erection of single piece nonlinear resistor type lighting arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV(rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required,
Painting with aluminium paint of approved brand and manufacture to give an even shed Two or More coats on new work
Tree Branch Cutting at various location in existing line at KOCM
Supplying & drawing/laying of PVC insulated XLPE aerail bunch power cable conductor 112/114 grade aluminium solid/ stranded conforming to IS- 14255-1955 part LL. Alu alloy messenger 1100 volts of approved make in air with necessary material as per specification of required size as mentioned below 3 X 70 sq mm + 1 X 16 (sq mm)
Total impact of GST for the purpose of CTC
M/S UMASHREE ENGINEERING (BID ID -1149982)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid