Krishna Bhagya Jala Nigam Limited
H B Konnur
Restoration of Installed Twin Tube Piezometers and standpipe Piezometer on LBED, RBED and Dyke at Narayanapur Dam
KBJNL/2024-25/DA/WORK_INDENT1355/CALL-4
KBJNL/2024-25/DA/WORK_INDENT1355/CALL-4
Open
Dam and Allied works
Electronic Documents, First(One Cover)
KBJNL Division Dam Division Narayanapur
7 documents required · 7 mandatory
₹1,030
₹82,000
3 Jun 2026
22 May 2026
29 May 2026
Restoration of Installed Twin Tube Piezometers and standpipe Piezometer on LBED, RBED and Dyke at Narayanapur Dam
Flushing of twin tube piezometers by triple x pump by applying water solvent(water solvent is prepared by using copper sulphate & aerol in required proportion by direct & reverse flushing methods to a...
Providing & fixing of Twin Tube Gauge for inlet and Outlet (including calibration certificate), 100mm bourdon type compound Hydrostatic gauge (including calibration). Units 0-60mt, Resolution 0.5% as ...
Providing & fixing of Outlet Valve and Inlet valve 6mm Brass Plug Valve with necessary fittings like Brass nipple, Brass half union, Brass coupling nut, Brass compression ferrule etc. are to be replac...
Providing & fixing of Master gauge (with calibration certificate) 200mm bourdon type compound Hydrostatic gauge (including calibration). Mt. per head, 0 100mt. units, Resolution plus or minus 0.2% as ...
Providing and fixing of triplex flushing Pump with self pressure controlling unit and two outlets or more outlets.
Supply & fixing of Panel board for fixing with Twin Tube Hydraulic Piezometer pipes, valves & gauges including all taxes
Supply & fixing of Stainless steel pipe system for connection of TTP to mastre gaueg and flushing pump of inner Dia. 8 mm with pressure capacity of 150 Kg/CM2
Providing & fixing of high pressure nylon pipes for connection between Piezometers to Treminal well starting point from ground
Additional AMC after completion of 1st year including flushing and data collection
Restoration of defunct Standpipe/casagrande piezometer provided on earthen embankments of Narayanpur dam including repair and painting to the cover box and replacement of standpipe and cap wherever ne...
Supply of readout unit for vibrating wire type piezometer
Supply of Standpipe/casagrande piezometer water level sounder
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tender Notification - KW2 Piezometer Call-4.doc
Others - Tender Notification • 0.13 MB
DTP KW2 format 1355 final CALL-4.doc
Tender Document • 3.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .