Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-Finance | L1 | Accepted-Finance BeingL1 | |
| 2 | L2₹17.6 L+₹2.0 L (12.7%)Accepted-Finance | L2 | Accepted-Finance BeingL2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to EMD submitted in favour of Executive Engineer instead of concerned Pradhan. hence rejected |
Tender Value
₹16.6 L
EMD Value
₹33,152
Closing Date
5 Oct 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer (PRI) South Andaman Division-I No. J/4, Old Councilor Bungalow Junglighat, Port Blair, South Andaman
Repair and Maintenance of (MPLAD) Community Hall (Basanti Temple) including Electrification at Guptapara under Gram Panchayat Guptapara.
2020_RDPRI_1092_1
EE/PRI/SAD-I/GEN/20-21/1042
Open Tender
Civil Works - Buildings
Works
90 days
Guptapara
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Executive Engineer GPPS
₹33,152
5 Nov 2020
21 Sept 2020
5 Oct 2020
21 Sept 2020
5 Oct 2020
22 Sept 2020
90 days
Amount
Providing and fixing up to floor five level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete.
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Fixed to openings / wooden frames with rawl plugs screws etc.
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in- charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
6 mm thick Cement fiber board as per IS:14276
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Finishing walls with water proofing cement paint of required shade :
Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.
0.63 mm thick with zinc coating not less than 275 gm/sqm.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating120 grams per sqm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete:
Ridges plain (500 - 600mm).
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i)Single socketed pipes.
110 mm diameter
Extra for providing and fixing wind ties of 40 x 6 mm flat iron section.
Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of :
Asbestos sheet
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within50 metres lead:
Of sectional area below 40 square centimetres
Wiring for Light Point /Fan Point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FLS PVC insulated copper conductor single core cable etc as required.
Group -C
Wiring for Light / Power Plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 no 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 x 2.5 sq.mm + 1x 2.5 sq.mm earth wire
2 x 6.0 sq.mm + 1x 6.0 sq.mm earth wire
Supplying and fixing following piano type switch/ socket on the existing switch box / cover including connections etc.as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing metal box of size 180 mm x100mm x60 mm deep (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection painting etc .as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc.as required.
Supplying and fixing following way , single pole and neutral , sheet steel , MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, power painted i/c earthing etc.as required. (But without MCB/RRCCB/Isolator)
8 way double door
Supplying and fixing 5 amps to 32 amps rating, 140/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required.
Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required.
Earthing with G.I. earth pipe 4.5 metre long,40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I Pipe from earth electrode including connection with copper thimble excavation and re- filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and Installation of 10W LED Bulk head wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. Make Havells or equivalent to ISI standard.
Supplying and installation of 20 w LED tube light fitting/ fluorescent tube fitting/ compact fluorescent fitting of all type complete with all accessories and tube etc. directly on ceiling/ wall,i/c connection with 1.5sq mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required .Make: crompton or equivalent to ISI standard.
Supplying and installation of ceiling fan (1200 mm sweep),i/c wiring the down rods of standard length (upto 30cm) with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required .Make: Bajaj or equivalent to ISI standard.
Supplying LED 15W CDL Lamp, Make: Havells or Equivalent to ISI standard
Supplying and installation of wall fan (400 mm , sweep), including making good the damage, connection, testing commissioning etc. as required. Make: crompton or equivalent to ISI standard.
Providing and fixing of syntex box of size 250mmx200mmx105mm for fixing of Energy Meter etc. as required
Maachandi Enterprises
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .