Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.8 LAccepted-AOC | L-1 | Accepted-AOC On L-1 basis | |
| 2 | L-2₹10.0 L+₹1.2 L (13.4%)Rejected-Finance | L-2 | Rejected-Finance Not accepted | |
| 3 | L-3₹13.8 L+₹5.0 L (57.0%)Rejected-Finance AHMEDABAD | AHMADABAD | GUJARAT | 363423 | L-3 | Rejected-Finance Not accepted | |
| 4 | L-4₹14.4 L+₹5.6 L (63.7%)Rejected-Finance | L-4 | Rejected-Finance Not accepted | |
| 5 | L-5₹17.4 L+₹8.6 L (98.1%)Rejected-Finance 119 120 MUNSHI VILLA 119 120 SHRI VIHAR DURGAPURA JAIPUR RAJASTHAN 302018 | JAIPUR | RAJASTHAN | 302018 | L-5 | Rejected-Finance Not accepted |
Tender Value
Refer Docs
EMD Value
₹12,410
Closing Date
6 Aug 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Materials Manager
Indian Oil Corporation Ltd. (Pipeline Division), Barauni Kanpur Pipeline, P.O. Barauni Oil Refinery, Begusarai 851114 (Bihar)
Supply and installation of D-Type TLPs in mainline under BKPL jurisdiction- Group B- Uttar Pradesh
2020_BKBRN_120505_2
BK/TS/900/2020-21/22
Open Tender
Electrical Works
Works
120 days
Allahabad
Please refer tender document
6 documents required · 6 mandatory
₹12,410
Yes
21 Oct 2020
16 Jul 2020
7 Aug 2020
16 Jul 2020
6 Aug 2020
20 Jul 2020
120 days
Amount
Supply and installation of vandal proof RCC test lead point (TLPs) of 8" dia of Reinforced cement concrete M - 20 with nominal mix of 1:1.5:3 with approved quality of stone chips 12mm to 6mm Size graded and clean coarse sand of FM2.5 to FM3 including providing end plug/cap threaded and providing electrical connection with 1c X 6 mm2 PVC multi stranded copper wire, 2 inch dia GI pipe (B class, lSI marked) of 1.5 mtr length threaded at one end to fit the vandal proof TLP Box & other end with bend pipe connection with a piece of GI pipe taking out from foundation for cable entries. All other materials required for erecting the test lead point over concrete foundation (TLP grouting) with cement concrete mixture 1:2:4 (Cement:Sand: Grit of 20mm nominalsize), making cable connection to the pipe with necessary excavation, removing 1" x 1" size of existing coating material on pipe surface, cleaning with wire brush and making the surface free of dust, surface preparation by acid wiping, thermit welding/pin brazing 1" length of Cu strands on exposed pipe surface, filling the exposed pipe and cable portion with liquid araldite (mixed with hardner), & terminating the cable on Bakelite insulating bolt with copper lugs, brass nuts /bolts, washer lugs inside the test lead box enrooting the cable through inside of the TLP box pipe , including removal of coat & wrap of dimension 75mm X 75mm , repairing the damaged to coat & wrap etc. and painting with one coat of Red Oxide zinc chromate primer and two coats of approved brand of synthetic enamel paint on the test lead box and GI pipe, complete in every respect as per drawing, specifications and instructions of Site Engineer inclusive of the cost of all labour, materials etc. "
[Earth Excavation For pipe Depth between 1.5 m to 5 m] Earth work in excavation in all kinds of soil except hard rock requiring blasting for foundation trenches, upto any depth including trimming of sides of the trenches, dressing, ramming and levelling the bottom of the trenches correct to level, grade etc. including bailing out of water, if any, filling in sides of foundation trenches, plinth etc. with the excavated earth available and/or depositing the excess earth, in layers not exceeding 20 cms. thick, consolidating each deposited layer by ramming, watering, dressing to level and grade , complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. For quantity calculation, the depth (height of excavation) shall be caclulated as pipe depth - 1.5 m.
H.R.Mahato
Pollen Technology
DSP ENTERPRISES
Jay Gauri Projects (I) Pvt. Ltd.
VIKAS INSULATION COMPANY
Keshayona Procon Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .