| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.7 L+₹1.5 L (3.62%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹43.8 L+₹1.6 L (3.84%)Rejected-Finance NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹44.1 L+₹1.9 L (4.49%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹44.1 L+₹1.9 L (4.54%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
22 Apr 2024, 6:00 pmClosed
GE Utility Secunderabad
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR/REPLACEMENT AND MAINTENANCE OF WATER SUPPLY DISTRIBUTION SYSTEM, LEAK PROOF VALVES, CLEANING OF WELLS AND TESTING OF WATER, REPAIR/REPLACEMENT OF CI PIPE/ DI PIPE LINE AND ALLIED WORKS AT ZONE 1C AREA UNDER AGE E/M NO I OF GE (U) SECUNDERABA
2024_MES_648833_1
GE(U)/SEC/TOKEN/92 OF 2023-24
Open Tender
Civil Works - Water Works
Item Rate
270 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (UTILITY) SECUNDERABAD
₹80,000
Yes
9 Sept 2024
1 Apr 2024
29 Apr 2024
1 Apr 2024
22 Apr 2024
15 Apr 2024
Amount
M&L for attending repair/rectification of external water supply complaints of GI/CI/DI/PP-R Pipe lines, sluice valves, gate valves of any type and size, Viz any type of leakages, no water supply and other water related complaints including transportation from complaint cell to complaint locations and back to complaint cell along with necessary T&P with provision of necessary excavation, returning and filling in as required at site, tightening of loose joints of union, elbow, sockets etc, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position including replacement of GI unions/sockets/nipples etc as required at site under Zone I C of AGE EM No.I areas and the following type of complaints all as specified and directed. Note : - Contractor should visit the site to understand site condition/distance between the complaint cell to the AOR before coating the rates. No claim in this regard will be entertained during execution stage.
All as per item No 1 here-in-before for GI tubing up to 32mm bore
All as per item No 1 here-in-before but for GI tubing 40 mm bore to 59 mm bore
All as per item No 1 here-in-before but for GI tubing 80 mm bore to 110 mm bore Notes for Sl item No 1 to 1.03:- (a) The contractor will be allotted complaints at MES complaint cell on required basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day complaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangement for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventory format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No I store yard on daily basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items No 9,10,11,12 & 13.
Taking up defective cast iron water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead from ground, cleaning the pipes free from sedimentation/scaling etc for reusing the serviceable pipes in repairs complete all as specified and directed for the following sizes:-
80 mm bore.
100mm bore.
150mm bore. Note for item Nos 2.01 to 2.03:- Excavation and earth work shall be measured and paid separately.
Re-laying only cast iron pipes obtained from item No.2 above including laying to level or to falls, in trenches or on the ground or on supports complete all as specified and directed for the following sizes:-
80 mm bore.
100mm bore.
150mm bore. Note for item Nos 3.01 to 3.03 :-Lead joints shall be measured and paid separately.
M&L CI pipes with spigot and socket ends centrifugally cast class 'LA' in any length suitable for tyton / lead joints laid in trenches including necessary cut to length to match the existing fitting/pipes, testing and making good disturbed surfaces of roads, path ways etc., while laying the pipe line at site complete all as specified and as directed for the following sizes:-
80mm bore.
100mm bore.
150mm bore. Note for item Nos 4.01 to 4.03 :-Lead joints shall be measured and paid separately.
Taking up or down GI/PVC/PP-R water tubing and connections including cleaning the pipes free from scaling for reusing the same in repairs / alteration or removable to store etc to water pipes and connections complete all as specified and directed for the following sizes:-
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
75/80 mm bore.
100/110 mm bore
Re-laying /refixing or rerouting of GI/PVC/PP-R old water tubing and connection in new or old position including fittings with old/new bends, elbows, socket nipples, tapers, and reducers etc as per site requirement (on floors, walls and ceilings) complete all as specified and directed.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
75/80 mm bore.
100/110 mm bore
Supply, lay and fixing steel water tubes, medium grade, ISI marked, galvanized with all fitting laid in trenches complete all as specified and directed for following bore of pipes :-
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
80 mm bore. Note :- Excavation and Earth work shall be measured separately.
Supply, laying and testing of Polypropylene random copolymer (PP-R) (PN-16/SDR 7.4)-3 Layers pipes, UV stabilized and antimicrobial welded having thermal stability with and including all PP-R plain & brass threaded polypropylene random fittings fixed such as bends, Elbow, Tee, Short Length, Socket, Union, Check Nuts, Nipples etc. (Females/Males as required), suitable for hot cold water supply line including making good disturbed surfaces/cutting chassis in CM 1:3, laid in trenches and including testing complete all as per manufacture’s instruction and all as specified and directed for the following outer dia of pipes:- Make:- SUPREME/PRINCE/KPT
20 mm bore (OD)
25 mm bore (OD)
40 mm bore (OD)
50 mm bore (OD)
75 mm bore (OD)
90 mm bore (OD)
110 mm bore (OD) Note :- Excavation and Earth work shall be measured separately.
Supply only GI fittings 20 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:- Make HB/TATA/ZOLOTO
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Elbow
All as per item No 08 here-in-before but for 25 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Elbow
Reducer elbow 25mm x 20mm
All as per item No 08 here-in-before but for 40 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Elbow
Reducer elbow 40mm x 25mm
All as per item No 08 here-in-before but for 50 mm bore.
Union
All equal Tee
Socket
Elbow
All as per item No 08 here-in-before but for 80 mm bore.
Union
All equal Tee
Socket
Elbow
S&F in replacement of unserviceable CI non raising type sluice valve both ends flanged with CI body, ISI marked, IS 14846, pressure PN 1.6 with SS spindle with clamps and check nuts, operating hand wheel complete all as specified and directed for the following sizes:-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
S&F MJ collar double ended flanged ISI embossed pressure 1.6 including jointing such as rubber gasket, nuts and bolts, washers materials etc complete including replacement of unserviceable sluice valves of any type complete all as specified and directed for the following sizes:-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
300 mm bore.
S&F DI socket ISI embossed pressure 1.6 including jointing such as rubber gasket, etc complete including replacement of unserviceable socket of any type complete all as specified and directed for the following sizes:-
100 mm bore.
150 mm bore.
200 mm bore.
300 mm Bore
Supply and fix gun metal gate valve, ISI embossed, conforming to is 781-1984, connected with iron wheel head, screwed at both ends for iron pipes and fixed including taking down of unserviceable gate valve complete all as specified and directed for the following sizes:-
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
S &F PP-R Gate valves (brass insert), with iron wheel head, screwed both ends for PP-R Pipes and fixed in repair for following bore of pipes :- Make:- SUPREME/PRINCE/KPT
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
Supply and fix Cast Iron Air Valves with two air Outlets, conforming to IS 14845 of size 100 mm dia bore double acting (DS2) heavy duty including providing jointing material such as rubber fiber board gasket, suitable size bolts and nuts and washers, necessary supports, rasing DI pipe 100 mm dia double side and not less than 1.20 Mtr length Including taking down old unserviceable Air release valve complete all as specified and as directed by Engr-in-charge. Note :- CI/DI specials required at site are measured and paid separately.
Supply and fix Cast Iron Air Valves with two air Outlets, conforming to IS 14845 of size 150 mm dia bore double acting (DS2) heavy duty including providing jointing material such as rubber fiber board gasket, suitable size bolts and nuts and washers, necessary supports, rasing DI pipe 150 mm dia double side and not less than 1.20 Mtr length Including taking down old unserviceable Air release valve complete all as specified and as directed by Engr-in-charge. Note :- CI/DI specials required at site are measured and paid separately.
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for laying of pipe lines, valve chambers, man holes etc including forming bottom surface to required level and gradient and getting out in hard /dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed.
Removing excavated soil to a distance not exceeding 59m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L cutting of road up to a size not exc 1.5m wide and not exc 1.5m depth for laying of water pipe lines making good the disturbed surfaces so as to match with existing finishing with PCC 1:2:4 type B1 , cement motor in CM 1:2 complete all as specified and directed
Burning out lead joints of the existing CI mains in position including removing old lead carefully without damaging the pipes etc complete all as specified and as directed for the following sizes:-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore. Note:- Excavation and earth work shall be measured and paid separately under the relevant Sch 'A' item.
M&L for lead joint for CI pipes including spun yarn etc for spigot & socket pipes and fittings complete all as specified and as directed for the following sizes:-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
M&L Rubber Gasket joints (Tyton joints) including rubber ring suitable for spigot and socket DI pipe and fittings complete all as specified and as directed for the following sizes:-
150 mm bore.
200mm bore. Note:- Excavation and earth work shall be measured and paid separately.
S&F ductile iron pressure pipes 200 mm bore, class K7, centrifugally cast with spigot and socket ends conforming to IS 8329/2000 with cement mortar lining inside the pipes and outside zinc coating suitable for push-on-joint including (rubber gasket D jointing) in any length as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm bore for inserting branch connections etc including taking down old existing one complete all as specified and directed :- Notes:- (a) DI pipe shall be laid in trenches at a depth of 1.0 to 1.5 m below the existing GL (b) DI specials will be measured and paid separately. (c) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department. (d) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
All as per Item No. above , here in before but 150 mm ductile iron pressure pipe
All as per Item No. above , here in before but 100 mm ductile iron pressure pipe Notes:- (a) DI pipe shall be laid in trenches at a depth of 1.0 to 1.5 m below the existing GL (b) DI specials will be measured and paid separately. (c) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department. (d) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
M&L for Construction of brick masonry valve chamber of size 1000 x 1000 x 1000 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 159 mm thick, 159 mm wide off sets all-round over 100 mm thick hard core, brick masonry walls built in CM 1:6, 59 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally and 159mm below GL externally and top of floor including excavation, earth work in hard/dense soil, 5 mm thick MS sheet cover fixed on 59 mm x 59 mm x 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of red oxide primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Disconnecting the delivery pipe line and electric connections of submersible pump set of 7.5 HP / 5 HP and removing it from its original position along with pipes and fittings carefully including chain pulley with tripod and transporting the same to the work shop situated within the city limits for repair and lowering including all pipes and fittings by means of chain pulley and tripod including connecting up of water and electric connections, testing and commissioning complete all as specified and directed. Notes:- (i) Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation from site to work shop and back are deemed to be included in unit rate quoted. (ii) Labour element is deemed to be included in unit rate quoted. (iii) Replacement of worn out parts and rewinding will be measured and paid separately under respective items No 31 & 33 will be measured and paid separately.
M&L for rewinding of the submersible motor with PVC insulated conductor with super enameled copper conductor, ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly for submersible motor of 7.5 HP capacity including taking down old unserviceable existing copper winding complete all as specified and directed.
All as per item No 39 here-in-before but for the submersible motor 5 HP capacity. (iii) Replacement of worn out parts and rewinding will be measured and paid separately under respective items No 31 & 34 will be measured and paid separately.
Supply only the following spares for repairs of submersible pump set of 7.5 HP capacity complete all as specified and directed.
Gun metal impeller
Stage casing
Stage casing bush (LB)
SS sleeves
Pump shaft
Pump coupling
Discharge outlet bush LB
Discharge outlet SS sleeves
Supply only the following spares for repairs of submersible pump set of 5 HP capacity complete all as specified and directed.
Motor bearing bush (LB) 04 Nos set
Thrust bearing set
NRV body
Section bush
Middle bush LB
Middle SS sleeve
Rotor (RE) work
Opening Mono block pump set 5 HP capacity for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered including cleaning, replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surfaces, making the pump and motor fully serviceable including machining etc and testing the both after refixing and commissioning for satisfactory operation on its full load complete all as specified and directed. Note : - (i) Replacement of worn out parts and rewinding will be measured and paid separately under respective items No 36 will be measured and paid separately.
M&L for rewinding of the mono block pump set 5 HP capacity with PVC insulated conductor with super enameled copper conductor ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old unserviceable existing copper winding complete all as specified and directed.
Supply only the following spares for repairs of Mono block pump set of 5 HP capacity:-
Ball bearing
Blind bush Gun metal
Gland rope nut
Terminal
Opening Mono block pump set 7.5/10 HP capacity for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered including cleaning, replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surfaces, making the pump and motor fully serviceable including machining etc and testing the both after refixing and commissioning for satisfactory operation on its full load complete all as specified and directed.
M&L for rewinding of the mono block pump set 7.5/10 HP capacity with PVC insulated conductor with super enameled copper conductor ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old unserviceable existing copper winding complete all as specified and directed.
Supply only the following spares for repairs of Mono block pump set of 7.5/10 HP capacity:-
Ball bearing
Impellers
PCV fan
Gland rope
Gland rope flang set
S&F DOL starter 3 phase 415 Volts, 7.5 HP capacity rating 14 Amps, relay range 9 to 14 Amps, MK-1, including connecting up of incoming and outgoing connections and testing commissioning, including removing the existing unserviceable one complete all as specified and directed.
S&F submergible pump controller stator in sheet metal enclosure 3 phase 415 Volts, 5 HP capacity rating 32 Amps, relay range 20-32 Amps, Type MF -G3 $ including connecting up of incoming and outgoing connections and testing commissioning, including removing the existing unserviceable one complete all as specified and directed.
S&F in repairs CI foot valve leather sheet type / flange type suitable for 80 mm dia GI suction heavy duty including replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.
S&F in repairs CI foot valve leather sheet type / flange type suitable for 100 mm dia GI suction heavy duty including replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.
S&F connecting and testing in repairs of non return valve of size 80 mm dia ISI marked , as per IS 5312 both ends flanged CI body with check nuts including jointing material complete all as specified and directed by Engr-in-charge.
S&F connecting and testing in repairs of non return valve of size 100 mm dia ISI marked , as per IS 5312 both ends flanged CI body with check nuts including jointing material complete all as specified and directed by Engr-in-charge.
Supply and lay submersible copper conductor cable 1100 volts grade PVC insulated, flexible, PVC sheathed with multistranded copper conductor of size 3 core 6 Sq mm cutting to required length connecting with necessary end ferrules / water proof joints including removing the existing unserviceable cable complete all as specified and directed
M&L Flushing of existing bore wells of size 150 mm dia, 150 Mtrs depth with drilling compressor including surging and flushing the bore at a pressure of 7 Kg / Sq cm complete with compressed air and flushing the sand, mud etc from the bore well till discharge of the fresh water, including testing of water samples for chemical and bacteriological tests and yield testing for 8 hours complete all as specified and directed .
S&F single phase preventer, SPPR type 360/380/415 volts suitable up to 7.5 HP pump including connecting up of wire / cable testing complete including removing the existing unserviceable one all as specified and directed. Make:-L&T Cat Part No CS81809OOOO or equivalent make in Indio Asian/Leagrand/ HPL.
Supply only free chlorine testing kit paper strips (Colome metirc TMG) for detection levels (0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.2, 1.5, 2.0, 4.0, 6.0 ppm (Mgle) test time 40 seconds having each bottle of 50 test strips complete all as specified and directed.
Design Fabricating supply and erecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor type front openable type, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15 mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Angle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6, type C2 using 40 mm graded stone aggregate, 45 CM below ground level and 15 Cm above ground level including taking down old existing one and consisting the following provisions:- (a) MCCB 63 Amp 25 KA 4 pole -1 No (b) DOL starter Heavy duty 7.5 HP with relay 9-14 Amp - 1No (c) Single phase preventer -1No (d) Pump ON and Supply ON indicator- 1 Set (e) Phase reversal protection for protecting motor from reverse running.
Supply only TCCA 90% Chlorine (Trichloroisocyanuric Acid), effective content of chlorine % : ≥ 90, Content of water % : ≤ 0.5, PH Value of 1% Solution: 2.7 to 3.3, Granular Chlorine/Tablet in packing of 50 kg complete all as specified and directed.
M&L for painting of water distribution header including all control valves and all exposed pipe of any size by using synthetic enameled spray painting after scrapping /cleaning complete all as directed at Napiers line
Supply only Water treatment chemical calcium hypo Chloride 65%-70% chlorine content (calcium based granular disinfectant for water treatment, packed in 45 kg drum complete all as specified and directed.
Taking down old unserviceable HDPE Pipe and High density polyethylene pipes (HDPE) of pressure rating 20 kgf/cm2 including socket for fixing with pump in borewell of size of size 50 mm complete all as specified and directed by Engr-in-Charge
Taking down old unserviceable HDPE Pipe and High density polyethylene pipes (HDPE) of pressure rating 20 kgf/cm2 including socket for fixing with pump in borewell of size 40 mm complete all as specified and directed by Engr-in-Charge
Supply and laying pipes ERW steel including specials, nominal dia 200mm as per IS 3589 (1981) 6.00mm thick and including cutting work, welding work and taking down of unserviceable ERW/CI pipe complete all as specified and directed by Engr-in-charge.
M & L for GI pipe heavy grade 50mm dia, cut into 3.0 Mtr length including providing of threading on both sides and lowering into the existing bore well along with existing GI pipe for increasing the length of the borewell pipe as in repairs complete all as specified and directed.
Reboreing/re-Drilling of existing borewell up to 350 mm dia, from the existing depth, at any type of strata by mud flash rotating equipment, from the Existing depth to 100 Meters . Notes:- (i) Water injection charges if required (ii) Transport Charges , (iii) , Vehicle settlings & Flashing charges (iv) Expendable stores like cotton waste / cleaning materials, (v) Labour element. should be included in unit rate quoted.
100 Mtr to 200 Meters
M&L for measuring exact depth of borewell by lowering 1/4" dia wire rope with its rolling stand all as specified and directed by Engr-in-charge.
M&L for cleaning of existing column pipes (3 Mtr length ) duly scraping, cleaning and painting complete through anti corrosive black bituminous paint all as per directed by engr-in-charge
Supply fix Steel wire rope anti corrosion (SS) of cage 6 mm thickness for fixing submersible pumps including necessary nut , bolt & clamps all as specified and directed by Engineer-in-Charge
Cutting anxious green growth/vegetation growth for cleaning out the area around STP AND E/M installations by JCB or Men Power at ground level by cutting out roots, un wanted plants bushes and removal of the same by surface excavation not exceeding 30 cm deep average 15 cm
M&L for Cleaning, de-slugging open wells at various locations by Eight Stage Method : - a) Removal of Complete Debris inside the well and surroundings. During cleaning safety measures like oxygen level inside to be checked. For every feet cleaning, Removing Debris addition of bioenzyme, Disinfection to be used.b) De-slugging the decomposed waste in the well for every 3000 litter Vacuum suction using Jetting machine. c) Sending the debris and waste water to Fecal Sludge Treatment Plant (FSTP) for further processing. Vendor should have authorised MOU with GOVT FSTP. d) Complete disinfection of the well area using 200 ml/liters chlorine solution using mechanical spray/long handled broom. Then addition Bio-Enzyme for further BIO remediation of the organic material at each steps up to depth of 30- 60ft. e) Disinfect the water in the well with a 50/100 mg/liters chlorine dosage (depending contamination) and leave for a minimum of 30 min on and dewater the well and allow it to fully recharge. f) After recharge check the chlorine residual in the water, where necessary, repeat the process of dewatering and recharging the well until, the chlorine level has reduced to 0.5 mg/liters or below. g) Covering the wells proper Geo Text Tile membrane 0.03 mm Thickness of Tencate Patented membrane imported from Malaysia. h) Applying of Biological weedicide around the well for good esthetical appearance and no further Bushy Development all as specified and as directed by Engineer-in-Charge.
Dismantling of existing pump unit, motor, pipes and any other parts of open well of AGE E/M No 1 Sub Station and servicing the pump and make it functional and reinstall after cleaning of wells complete all as specified and directed by Engineer-in-Charge . The work shall also include all needed equipment (hoist, tripod, crane, electric generator... etc.) to complete the work as required. The cleaning of wells shall be measured and paid separately under relevant item of the schedule A.
SRI SAI RAM ENTERPRISES
THE DECAN ENGINEERING AND REFRIGERATION COMPANY
Srinivasa Consructions
SUN LIGHT HOUSE
Haasith constructions
sandhya enterprises
Sri Balaji Enterprises
Mavee Syndicate
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .