Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC AT PO SURYA NAGAR HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | L1 | Accepted-AOC the rate quoted by L1 Bidder M/s B.K Enterprises is 40.01 percent below the estimated cost / 41.65 percent below the updated cost | |
| 2 | L2₹5.4 L+₹66,154.83 (13.9%)Rejected-AOC AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L2 | Rejected-AOC On being L2 | |
| 3 | L3₹7.0 L+₹2.3 L (47.8%)Rejected-AOC AT GURUDHWAR NEAR UCO BANK SOUTH BALANDA TALCHER DIST ANGUL ODISHA PIN 759116 | TALCHER | ANGUL | ODISHA | 759116 | L3 | Rejected-AOC On being L3 |
Tender Value
₹7.9 L
EMD Value
₹10,000
Closing Date
22 Aug 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Vijay Kumar Staff Officer(EnM) Lakhanpur Area
Vijay Kumar Staff Officer(EnM) Lakhanpur Area GM Office Bandhabahal Dist-Jharsuguda Odisha-768211 Mob-9437595715
Repair and maintenance of LT and HT over headline at BIT Colony, Lakhanpur Area, MCL
2022_MCL_253208_1
MCL/LKPA/EnM/eNIT/22-23/59 Dt-11.08.2022
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
BIT Colony, Lakhanpur Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
10 Oct 2022
11 Aug 2022
24 Aug 2022
11 Aug 2022
22 Aug 2022
12 Aug 2022
11 Aug 2022 - 15 Aug 2022
Amount
Consolidation of Pole
Excavation including refilling as required-(0.253) cum x 112 nos.=28.336 cum
Cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size )
LT OVERHEAD LINE WORK
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. -Above 8.0 metre and upto 11.0 metre
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightner, 7/3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Erection of ACSR conductor upto 7/2.11 mm to 7/3.00 mm diameter and above including binding etc. as required.
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required .
Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
HT OVERHEAD LINE WORK
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6(1 cement ,3 coarse sand,6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as reqd. - Above 11 mtrs and upto 13 mtrs
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying of two lengths of channel iron 100mmX50mmX6mm(9.56 kg per metre) double pole cross arm for three wire 33kv overhead line conductors complete with through bolts and nuts for clamping to the poles,50mmX6mm M.S.flate welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together,including drilling holes for insulator pins/fittings, bolt, nuts, washers etc and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Erection of G.I. wire No. 8 swg including binding etc as required.
Supply of G.I wire
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required .
Erection of ACSR conductor upto 7/3.35 mm to 7/4.00 mm diameter and above including binding etc. as required.
HT OVERHEAD LINE WORK
Providing of Cradle Gaurd in various crossing
Total impact of GST for the purpose of CTC
M/S LIGHT PALACE
M/s Evergreen Electrical Works
stage.html
html • 0.04 MB
techsummary_261784.pdf
PDF • 0.48 MB
finsummary_261784.pdf
PDF • 0.51 MB
LOA59.pdf
PDF • 0.74 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .