| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹13.3 L+₹16,696.75 (1.27%)Rejected-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 3 | L3₹16.3 L+₹3.1 L (23.6%)Rejected-AOC | L3 | Rejected-AOC REJECTED DUE TO NOT LOWEST |
Tender Value
₹15.5 L
EMD Value
₹31,500
Closing Date
15 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
PROVISION OF CERTAIN MAJOR REVENUE WORKS AND MINOR WORKS AT AIR FORCE STATION PUNE
2021_MES_471429_2
8511/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹31,500
Yes
10 Jan 2022
28 Oct 2021
22 Nov 2021
28 Oct 2021
15 Nov 2021
3 Nov 2021
60 days
Amount
Surface excavataion n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manhole, pier holes, etc and getting out any type of soil complete all as specified and directed.
Ditto all as per Ser Item No 2.00 above but soft/disintegrated rock complete all as specified and directed.
M&L Cement Concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for PCC Block masonary with solid blocks, exc 10 cm in width and setting in mortor in CM 1:6 type C1 1:3:6 (20 mm graded aggregate) complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removal of excavated material as soils not exceeding 50m and at a level not exceeding 1.5m above the starting point and depositing complete all as specified and directed.
Earth filling under floors,spreading,levelling in layers n.exc 25cm thick each including watering & well ramming complete all as specified and directed.
Broken stone or Boulders Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded agg) as in Sub-base to floor finishes complete all as specified and directed.
M&L 25mm thick Cement concrete 1:2:4 type B-O(using 12.5mm graded aggregate) as in flooring complete all as specified and directed.
M&Lfor 20mm thick screed bed or bedding layer of mortar in CM 1:4 for laying floor finishes such as kota flooring complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) as on external surface on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
Material and labour for 10 mm thick rendering in cement mortar (1:6) as in internal surface on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
Material and labour for 5 mm thick rendering in cement mortar (1:3) on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6, type C-2 (using 40mm graded agg) as in plinth protection finished even and smooth using extra cement.(incl necessary joint filling with mixture of paving bitumen & sand in 1:3) complete all as specified and directed.
Reinforced cement concrete nominal mix Type B-1 1:2:4, using 20 mm graded crushed stone aggregate as in lintel bands or roof beam etc. complete all as specified and directed.
Form work to sides and soffits of floor or roof beams beam , lintels, cantilevers, shelves etc with rough finished surface complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works not exc 20 cm wide and sides of PCC/RCC bands exc 10 cm but n.exc 20 cm wide with rough finished surface complete all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide fair finished surfaces of concrete complete all as specified and directed.
RCC (nominal mix) Type B-1 1:1.5:3, using 20 mm graded crushed stone agggregate as in slabs supported on walls beams and columns in floors, roofs, landings, balcony, canopies, deck slabs and in shelves and the like complete all as specified and directed.
RCC nominal mix Type B-1 1:1.5:3, using 20 mm graded crushed stone agggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns complete all as specified and directed.
RCC nominal mix Type B-1 1:1.5:3, using 20 mm graded crushed stone agggregate as in for columns complete all as specified and directed.
RCC nominal mix Type B-1 1:1.5:3, using 20 mm graded crushed stone agggregate as in for chajjas complete all as specified and directed.
S&F APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. Not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
TMT bars (Fe 500), 10mm dia and over in reinforcement cut to length,bent to shape reqd, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto all as per Ser Item No 28.00 here-in-before but 8 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders complete all as specified and directed.
M&L for preparing newly plastered surfaces on ceiling and applying three coats of white wash complete all as specified and directed.
M&L Preparing newly plastered or concrete surfaces of wall and applying two coats of cement based paint over a coat of white wash complete all as specified and directed.
M&L for preparing newly plastered surfaces on wall and applying two coats of Oil bound distemper over a coat of white wash complete all as specified and directed.
S & F 1.00mm thick of laths as Steel rolling shutters, without ball bearing, as specified including rod, hasp and staples and one shop coat of primer, erected in position as indicated, Push pull or manual type complete all as specified and directed.
M&L for preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
Material and labour for 10 mm thick rendering in cement mortar (1:3) on fair face of brick or concrete surface including mixing of water proofing compound as per manufacture's instructions (water proofing compound shall be measured and paid separately) complete all as specified and directed.
Supply only liquid water proofing compound @ 0.200 Ltr per 50 kg of cement cement or as per manufacturer's instructions, complete all as specified and directed.
S & F Anodised aluminium window and ventilator shutters, fixed type without sash bar, alluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber packing, anodised aluminium snap beading screws etc complete all as specified and directed.
S & F Sheet Glass, Ordinary quality 5.5 mm Thick including necessary rubber beading complete all as specified and directed.
M&L for laying/spreading of sand as in 25 mm thick cushion to precast concrete interlocking paver block incl watering & consolidating complete all as specified and directed.
M&L for 60mm th Machine pressed precast concrete interlocking coloured rubber mould paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, jointed with grey cement and pigment complete all as specified and directed.
Plain Cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) in edging of path (interlocking paver) and the like including weathering slightly rounded or chamfered angles as directed including form work and finishig all exposed surfaces complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Roof trusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe 410 -W (Gde-E- 250) quality-A complete all as specified and directed.
M&L for suspended false ceiling using anodized aluminium snap grid frame work for false ceiling, Size of grid 605 x 605 mm fixed to soffits with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia. 40mm long and Perforated particle board/ tiles of size 12 mm thick for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
Excavating in post holes for hard / dense soil (or similar holes) each not exc 0.5 Cum in any type of soil, getting out, returning fillimg in and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm thick watering and well ramming and removing surplus soil to a distance n, exc 50m and making good surface complete all as specified and directed.
Cement concrete 1:2:4 Type B-2 using 40mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and directed.
S&F pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L 100mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified and directed.
M&L 40mm thick Cement concrete 1:2:4 type B-1(using 20mm graded aggregate) as in flooring, finished surfaces even and smooth without using extra cement complete all as specified and directed.
S&F precast RCC BENCH of stand size for capacity of 3 people without hand stand and with back as support complete all as specified and directed.
Cement concrete 1:3:6 Type C-2 using 40mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and directed.
M&L rendering in CM 1:4 of 10mm th on internal fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L for prepration of new plaster surfaces of wall for applying three coat of white wash complete all as specified and directed.
M&L for moorum/red bazari filling in floors or paving, laid in layers n'exc 15 cm thick, spread,levelled and rammed incl watering complete all as specified and directed.
M&L for hardcore with brocken stone of gauge n'exc 53mm deposited,spread and levelled and layers n'exc 15 cm thick, water and rolled/rammed to a true surfaces complete all as specified and directed.
M&L 70 mm thick PCC type B1, 1:2:4 (using 20mm graded stone aggregate) as sub base complete all as specified and directed.
M&L forming construction (dummy) joint 65mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed.
S & F Steel work in tubular/hollow trusses/structure etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 and structural steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and directed.
S& F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with rivetted /bolted or welded attachment conforming to Fe 410W (Gde E-250, quality A) complete all as specified and directed.
M & L Providing, cement concrete 1:2:4 B0 (12.5mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M & L wind ties for roof including securing bolts complete all as specified and directed.
M&L for providing point wiring with two runs of 1.5 Sqmm multi standed copper conductor FRLS PVC insulated single core 1100 volts grade with one runof 1.5 sqmm single core multi standed copper conductor FRLS PVC insulated single core 1100 volts grade wire for continious earthing complete in and including PVC coating and caping with all fitting/fixture etc and open recessed type plastic Enclouser (plastic switch Board) ISI mark-14772 for housing switches/sockets complete all as specified and directed.
One exhaust/wall mounted/ceiling point controlled by one regulator/switch
S&F switch/socket combination multipurpose 5 pin 5 Amps complete all as specified and directed.
S&F wall mounted fans 230 volts single phase oscillating 400mm sweep suitable for wall mounting complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /culverts or enclosed in GI pipe/ fix complete all as specified , for following size:- a) 10 Sq mm X 2 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc. complete all as specified and directed.
Soft/loose soil
Hard/dense soil
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed. [Note : Measuremenet will be done after punning]
Supplying and laying un-reinforced precast concrete cable cover, class I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and directed.
S&F GI tubing 50 mm bore medium grade galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading complete all as specified and directed. Note: (a) GI pipe to be laid in road crossings (b) The cost of making good of road must be included in the quoted rate
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor Flame retardant PVC insulated 1100 Volts grade wire for continuous earthing complete drawn in stove enamelled steel conduit with all accessories concealed in wall or surface for housing switches / sockets complete all as specified and directed.
One light point controlled by one switch .
Supply and fixing of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F FLP - Weather proof enclosure for LED tube light fitting with 1 X20 W (4 feet) tube rod with all standard accessories ,cable glands , reflectors , wire guard in aluminium alloy incl. necessary fixing arrangements suitable at site & CMRI certified IP 65 protection complete all as specified and directed.
Supply and fixing MCB DB SPN 4 way with 200 amps rated bus bar IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as specified and directed.
S&F MCB DP 32 Amp 10 kA 240 Volt, 'C' Curve and electric connections with copper thimbles complete all as specified and directed.
M&L for MCB SP 6-32 Amps C curve and electric connections with copper thimbles complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor Flame retardant PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor Flame retardant PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and directed.
One light point controlled by one switch .
One Fan point controlled by one regulator/switch.
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A on the same switch board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor Flame retardant PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded Flame retardant PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing one 15 A Switch / sockets complete all as specified and directed.
Supply and fix switch piano flush type 5 Amp one way complete all as specified and directed.
Supply and fix Socket out let 2in 1, 5 pin 5 Amp complete all as specified and directed.
Supply and Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed.
Supply and fix switch piano flush type 15 Amp one way complete all as specified and directed.
S & F Fan Regulator electronic step type 400 W complete all as specified and directed.
S&F angle / batten holder insulated body with back plate for batten fittings complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm complete all as specified and directed.
Supply and fix high quality indoor Surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete all as specified and directed.
Supply and fix MCB SP 240 V ,6 to 32 Amps complete all as specified and directed.
Supply & fix Industrial wall mounted fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting complete all as specified and directed.
Supply and fix in repair ceiling fan 1200 mm sweep 230 volts, 5 star rating including blades , canopy & down rod complete all as specified and directed.
R k construction
R K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .