Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38,000Accepted-Finance 23609 A INDERJEET SINGH BATH MANSA ROAD NEAR I T I CHOWK BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-Finance Lowest | |
| 2 | L2₹56,640+₹18,640 (49.1%)Rejected-Finance | L2 | Rejected-Finance Due to not lowest | |
| 3 | L3₹78,500+₹40,500 (106.6%)Rejected-Finance | L3 | Rejected-Finance Due to not lowest | |
| 4 | L4₹1.4 L+₹1.0 L (275.7%)Rejected-Finance BIMAL SINHA SARANI HAKIMPARA SILIGURI SILIGURI HAKIMPARA DARJEELING WEST BENGAL 734001 | JALPAIGURI | WEST BENGAL | 734001 | L4 | Rejected-Finance Due to not lowest | |
| 5 | Not Admitted-Fee/PreQual/Technical 86 INDUSTRIAL AREA PHASE 1 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | - | Not Admitted-Fee/PreQual/Technical Others-Registration under K & L category not uploaded for technical evaluation nor any experience for execution of Job title work |
Tender Value
Refer Docs
Closing Date
23 Dec 2022, 9:00 amClosed
MAJ NEHAIL SHAHNAWAZ
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (P) BATHINDA MIL STN
SOIL INVESTIGAION FOR PROVN OF ACCN AT BATHINDA MIL STN
2022_MES_558733_3
3007/JOB/eProcure/2022-23/6/E3
Open Tender
Job Works
Item Rate
45 days
GE (P) BATHINDA
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
24 Dec 2022
8 Dec 2022
24 Dec 2022
8 Dec 2022
23 Dec 2022
9 Dec 2022
Amount
Performance of standard penetration tests as per IS 2121:1981 on ordinary soil consisting of clay/silt/sand /or their mixture at an interval of 1.5m or change of strata & collection of samples from bore holes upto depth of 10.0m or up to refusal (N>50) & conducting laboratory tests i.e grain size analysis, atterberg limits,cohesion,intercept,angle of shearing resistance,free sweell index,bulk unit weight, natural moisture content etc. evaluate allowable bearing capacity on shear strength as well as on settlemet through triaxial shear strength test as per IS 2720 part II, consideration alog with strata bore logs & comprehensive report for the proposed sites. Note: Depth of bore holes for S/S bldg shall not be less than 8m. (a) Chemical analysis of soil . (b) Chemical analysis of Ground water. Note:Under this test following results also be provided: i) Grain size analysis, identification & classification of soil. ii) Unit weight (bulk density), natural moisture content, liquid limit, plastic limit. Shrinkage limit, plasticity index, specific gravity. iii) Dry density, degree of saturation of soil. v) Shear parameters (C-Ø analysis using DST/Triaxial test). vi) Consolidation test & permeability test. vii) Depth of water table below ground level. viii) Presence of loose soil. If any and its depth. ix) If weak soil with lesser N value as specification in table-1 of IS 1893 (Part-) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. x) SPT test shall be done at 1.0m interval. xi) Recommendation for filling under floor and filling under protection including plinth protection. xii) For open foundation, calculation of net SBC at 1.5m, 2m, 3.0m from shear as well as settlement criteria. SBC values shall be calculated based on C- Ø analysis as well as SPT value. For calculation formula given in IS 6403 shall be used. Calculation sheet to be attached with report. xiii) Recommendation regarding type of foundation to be adopted & net SBC/Pile capacity to be adopted. Also, recommendation shall be given regarding stability of soil and soil stabilization required, if any. xiv) Borehole position duly marked on plan and their distance from adjacent prominent reference points. Plan size of bldgs shall also be marked in the plan. This plan shall be signed by GE, AGE & Soil consultant. xv) Bore log details shall be as per Appx 'D' of IS 1892 N values depth wise shall also be shown in bore log details. Bore log details shall be signed by GE, AGE & soil consultant. xvi) Colour photograph on A4 size photo paper of the site with the locations of the boreholes duly flagged should be submitted. The photographs should also preferably include any reference structure and the identification of the same be marked. xvii) Undisturbed soil sample shall be collected at 1.5m interval and at change of strata.
same as item No. 1 but depth up to 12m min or up to refusal (N>50) for D/S bldgs refusal
Chemical analysis of soil and recommendation and type of cement to be used for RCC foundation
Chemical analysis of ground water (water to obtained from bottom of bore hole) Note :- A CD containing video evidence of the depth of each borehole and machinery deployed at site location will be provided which is inclusive in above quoated rate alongwith 04 x sets of hard copy in good quality spiral binding of complete report shall be submitted to this office.
Sheltera consultants pvt ltd.
M/s Mat Lab Engineers Enterprises
Kristi Engineering Services Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .