| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13,340Admitted-Finance | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VIPIN ELECTRICALS L1 |
|---|---|---|---|---|
| 1.01 | fixing of dismanteled 1.0/1.5/2.0 TR of Split AC on other site as required. | 1 | Nos | 1,625 ₹1,625 Lowest |
| 1.03 | P & Replacement of fan blade outdoor unit of Split AC. 1.5/2.0 TR A.C as required. | 1 | Nos | 2,010 ₹2,010 Lowest |
| 1.04 | P & Replacement of swing motor/ Roter Split AC. 1.5/2.0 TR A.C as required. | 1 | Nos | 1,365 ₹1,365 Lowest |
| 1.05 | P & Replacement of senser Split AC. 1.5/2.0 TR A.C as required. | 1 | Nos | 1,000 ₹1,000 Lowest |
| 1.06 | P & Replacement of Fan motor Split AC. 1.5/2.0 TR A.C as required. | 1 | Nos | 2,820 ₹2,820 Lowest |
| 1.07 | P & Replacement of PCB plate Split AC. 1.5/2.0 TR A.C as required. | 1 | Nos | 4,520 ₹4,520 Lowest |
Tender Value
₹6.2 L
EMD Value
₹12,300
Closing Date
9 Feb 2026, 6:00 pmClosed
DC
dc
AC installation and maintenance Rate Contract 2026-27
2026_DLB_534383_1
883
Open Tender
Miscellaneous Works
Percentage
365 days
Nagar Nigam
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
In bank account as per bid details
₹12,300
Yes
17 Feb 2026
2 Feb 2026
10 Feb 2026
2 Feb 2026
9 Feb 2026
2 Feb 2026
fixing of dismanteled 1.0/1.5/2.0 TR of Split AC on other site as required.
P & Replacement of fan blade outdoor unit of Split AC. 1.5/2.0 TR A.C as required.
P & Replacement of swing motor/ Roter Split AC. 1.5/2.0 TR A.C as required.
P & Replacement of senser Split AC. 1.5/2.0 TR A.C as required.
P & Replacement of Fan motor Split AC. 1.5/2.0 TR A.C as required.
P & Replacement of PCB plate Split AC. 1.5/2.0 TR A.C as required.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter. 1.5 TR Window/ Split A.C.
2.0 TR Window/ Split A.C.
Replacement of defective compressor by company repaired compressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 1.5 TR A.C.
P & Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.1.5 TR A.C.
Servicing of 1.0/1.5/2.0 TR capacity Split/ Window type air conditioner
P & Replacement of overload protection of A.C./ Water cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
P & Replacement of thermostat of A.C./ Water cooler/fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
P & Replacement of starting relay of A.C/water cooler/fridge compressor as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire. Starting capacitor40-60 micro farad
Running capacitor 2.5/3.15 micro farad
Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 4 core x 2.5 Sq.mm
Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 25 mm
Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
Dismantling of split air conditioner of any capacity/any type including existing indoor unit & outdoor unit , refrigerant piping , connecting cables , drain pipe etc. including shifting of dismentaled material to store complete as required
Supply, Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure ""A"" attached with this BSR . 2.0 TR ISEER not less then 4.6
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
ebid1.pdf
Tender Documents • 4.83 MB
BOQ_952230.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .