| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹1.2 Cr | L1 | Accepted-AOC ACCEPTED BEING L1 BIDDER |
| 2 | L2₹1.2 Cr+₹12,261.80 (0.10%)Rejected-AOC 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹1.2 Cr+₹12,261.80 (0.10%) | L2 | Rejected-AOC NOT ACCEPTED BEING L2 BIDDER |
| 3 | L3₹1.3 Cr+₹10.2 L (8.40%)Rejected-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.3 Cr+₹10.2 L (8.40%) | L3 | Rejected-AOC NOT ACCEPTED BEING L3 BIDDER |
| 4 | L4₹1.4 Cr+₹15.0 L (12.3%)Rejected-AOC | ₹1.4 Cr+₹15.0 L (12.3%) | L4 | Rejected-AOC NOT ACCEPTED BEING L4 BIDDER |
| 5 | L5₹1.4 Cr+₹16.1 L (13.3%)Rejected-AOC | ₹1.4 Cr+₹16.1 L (13.3%) | L5 | Rejected-AOC NOT ACCEPTED BEING L5 BIDDER |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
21 Aug 2021, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH, MES, PO-PANAGARH, DIST- BURDWAN,WB-713420
PROVN OF DEDICATED 11 KV UG FEEDER FROM MRS BUDBUD TO PH1 AT PANAGARH MIL STN GE PANAGARH
2021_MES_460818_1
8705/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
PANAGRH
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE PANAGARH
₹2.2 L
Yes
13 Sept 2021
17 Jul 2021
23 Aug 2021
17 Jul 2021
21 Aug 2021
9 Aug 2021
Amount
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil , complete all as specified and as directed.
Excavation in trenches exceeding 1.5 m or part or part thereof in depth beyond the first 1.5 , complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil, complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point , complete all as specified and as directed.
Supply and lay dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and as directed. Note : Punned thickness shall be measured.
M&L for un-reinforced precast concrete cable cover, class HV, type I with peak, size 300mm x 180mm x 40mm with MES marking on the top of the cover , complete all as specified and as directed.
Material, Laying and testing in trenches or passing through pipe 11000 volts grade, heavy duty XLPE insulated cable, Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, Pressure extruded PVC innersheath, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments of aluminium conductor cross sectional area 185 Sqmm 3 core, complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sq mm, complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sq mm, complete all as specified and as directed.
Supply and fixing cable jointing kit for 11KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sqmm , complete all as specified and as directed.
M&L for pre stressed concrete pole 11 meter long 152 mm x 152 mm at top and 152 mm x 260mm at bottom class 9 complete including PCC (1:3:6) type C2 (using 40 mm stone graded stone aggregate in foundation and copying with PCC (1:2:4) type B1 (using 20mm stone aggregate) ,complete all as specified & as directed. Note: PCC anti climbing device, cross arms insulator, ACSR conductor and earth work measure and paid separately
M&L for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms, complete all as specified and as directed.
M&L for switch air break gang operated triple pole out door type unit HT 11 KV 50 cycle AC suitable for current rating upto 400 Amps mechanically operated mounted on insulators (9 insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement, complete all as specified and as directed.
S&F Horn gap fuse (Copper) channel type fitted on two post insulator per pole per phase complete vertical type (6 insulators) connected with necessary nut bolts brackets including testing confirming to IS 9835 rating 12 KV, 400 Amps made of Gun metal including taking down old unserviceable , complete all as specified and as directed.
M&L for Lightening arrester/surge protector 11 KV grade expulsion type with all fittings, transmission class and discharge capacity of 65KA , complete all as specified and as directed.
Shifting of 11 KV 4 Panel VCB for connection of new VCB panel including connections and fixing at new place with nut, bolts etc, complete all as specified and as directed.
Shifting of 33 KV Control Panel including connections and fixing at new place with nut, bolts etc , complete all as specified and as directed.
Shifting of 30 V DC Battery charger including connections and fixing at new place with nut, bolts etc , complete all as specified and as directed.
Supply, installation, testing & commissioning of 11 KV of rating 630 Amps RMU unit outdoor type (IP-54) protection duly painted ,SF-6 gas insulated RMU (Ring main unit) Three way comprising of Two numbers SF6 insulated load break switch as outgoing and one number Vacuum Circuit Breaker as incoming inside SF6 gas filled stainless steel (nonferrous and nonmagnetic grade) tank having IP-67 degree of protection with painting as per manufacturer specification & leak rate of SF-6 gas less than 0.1% , gas refillable at site/factory. RMU should be provided with Copper Bus bar, one number fault passage indicator , mechanism for interlocking arrangements for powered relay complete with all accessories as under. (a) RMU type installation Outdoor type, arc proof as per IEC: 62271-200 for design, Manufacturing and testing. The RMU must have the following features/specifications :- (i) Rated Voltage upto -12 KV. (ii) Rated power frequency withstand voltage -28KV. (iii) Rated lightning impulse withstand voltage -should be minimum 95 KVP. (iv) Rated current for ring main feeder -630A. (v) Rated current for VCB feeder- 630A. (vi) Rated short-time current-21 KA/3 Sec. (vii) Rated short making current -52.5 KA. (viii) Ambient temperature- (-1 degree Celsius to +45 degree Celsius), (ix) Degree of protection against accidental contact and ingress of foreign objects must be assured as under :- (aa) Main electric circuits : IP-67, (ab) Fuse compartment IP3X, (ac) Operating mechanism -IPXC, (ad) Cable connection compartment -IP2XC with site replaceable cable busing. (x) Each load break Switches includes:-
Supply, Installation and commisioning of indoor type 11KV vacuum circuit breaker (VCB) with indoor switchgear panel equipped with CT, PT & protection relays of rated voltage 11KV, 400A, 250MVA rupturing capacity & short time current rating 13.1KA for 3secs, shunt trip floor mounted, horizontal isolation, horizontal draw out with integral earthing facility, internal arc tested with degree of protection IP4X, dustproof, vermin proof totally enclosed in connection/linking with already existing VCB busbar chamber at site as per detail specification as follows; 1. In panel rating - 400 Amps 2. Vacuum Circuit Breaker - 01 No 2.1 Rated Current - 630A 2.2 Release combination - 1 shunt release 2.3 Spring charging motor - AC 220-240V 2.4 Closing solenoid - DC30V 2.5 Tripping Coil - DC30V 2.6 Second tripping coil - Without 2.7 Auxiliary switch contact - 6NO+6NC+64pin socket 3. Current Transformer (Set 1) 3.1 Type of CT - HT CT 3.2 CT ratio - 150 A/ 5A / 5A 3.3 Core 1(Rating/ class) - 5VA/1.0 3.4 Core 2(Rating/ class) - 5VA/5P10 4. Potential Transformer (CC) 4.1 PT primary - 11/ √3KV 4.2 PT secondary - 110/ √3V/110V/3 4.3 Core 1(Rating/ class) - 100VA/ CL1.0 4.4 Core 2(Rating/ class) - 50VA/CL.3P
Item No 20 Contd.... 5 Ventilation Box/Louvers- Without ventilation 6 Cable connection type 6.1 Direction of entry - Bottom 6.2 Number of cables per phase - 1R×3C 6.3 Size - 300 sqmm 7 Secondary devices- 01no 7.1 VAJH13 - 01no 7.2 Pin Type Bulb - 01nos 7.3 Digital Ammeter - 01no 7.4 L/R switch - 01set 7.5C-Link 10nos 7.6 Indicating Lamp 01no 7.7 7SR10 (50,51,50N,51N,74TC with RS-485 port communicable on IEC-60870-5-103 protocol - 01set 7.8 MCB 2P - 02set 7.9 Control Fuse - 01no 7.10 Limit Switch - 01no 7.11 Digital Voltmeter - 01no 7.12 T/N/C Switch - 01no 7.13 Push Button - 01no 7.14 MFM,CL-1,RS-485 - 02nos 7.15 Auxillary Contactor - 2NO+2NC 02nos 7.16 VAA33(Trafo Auxiliary relay) - 01no 7.17 Switch Socket Block 11KV, 3ph, 3 wire, 50 Hz air insulated Aluminium feeder and suitable for a short circuit capacity of 13.1kA for 3 second. 7.18 The switch board -01no
Item No 20 Contd.... 8. The switchgear panel comprise of standard pre-fabricated cold rolled sheet steel units assembled (bolted) to form a rigid, free standing structure with Sheet Steel Thickness (CRCA in mm) of suitable size of existing VCB. Note: Contractor can visit site for size/dimensions of existing VCB for connection of new VCB panel with adaptor/busbar panel
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32 x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSr part 1 including testing on completion all as specified and as directed.
S&F 100 mm bore steel tubing medium grade ISI marked for protection of cable including necessary joint and clamps complete with taking down old unserviceable, complete all as specified and as directed .
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure and depth of boring not exceeding 3 meter from ground level, complete all as specified and as directed .
S&F Current Transformer 11KV, single phase indoor resin cast, ratio 200-100/5-5-5A, Triple core, class 1.0-5P 10 burden 15/30VA insulation level 28KV/75KV as per IS-2705 to suit existing VCB incl taking out old CT ,Complete all as specified and as directed.
Supply and fix RCC Cable route indicator of size 800x300x100 mm duly written 'MES HT CABLE" in Block letter duly painted with synthetic enamel paint over one coat of primer and fixing with PCC (1:2:4) B1 using 20 mm graded stone in 450x450x300 mm volume for fixing route indicator,Complete all as specified and as directed. Note : Prior approval of route indicator colour to be taken from Engr-in-Charge.
Supply and fixing RCC Cable route indicator of size 1300x300x100 mm duly written 'HT CABLE JOINT" in Block letter duly painted with synthetic enamel paint over one coat of primer and fixing with PCC (1:2:4) B1 using 20 mm graded stone in 600x450x300 mm volume for fixing route indicator,Complete all as specified and as directed. Note : Prior approval of route indicator colour to be taken from Engr-in-Charge.
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundation for stay set /Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement, complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 with using 20 mm graded stone aggregate as in coping of pole including necessary form work as required ,Complete all as specified and as directed.
M&L for fly ash brick in CM (1:4) using sub class B bricks straight or curved on plan exceeding 6 M mean radius ,Complete all as specified and as directed.
M&L for 15mm thick in cm (1:4) rendering on fair face of brick work finished even & smooth without using extra cement complete all as specified & as directed.
NIRMAL SALES CORPORATION
Prasur Electricals & Engineering Co.
BUSINESS SYNDICATE
KR POWER INFRA INDIA PVT LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .