Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹21.9 L Quoted ₹22.4 L | L1 | Accepted-AOC L bidder |
| 2 | L2₹23.5 L+₹1.0 L (4.66%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹23.5 L+₹1.0 L (4.66%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹24.4 L+₹2.0 L (8.89%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | ₹24.4 L+₹2.0 L (8.89%) | L3 | Rejected-Finance Higher bid value |
| 4 | L4₹25.4 L+₹3.0 L (13.3%)Rejected-Finance | ₹25.4 L+₹3.0 L (13.3%) | L4 | Rejected-Finance Higher bid value |
| 5 | L5₹25.8 L+₹3.4 L (15.1%)Rejected-Finance | ₹25.8 L+₹3.4 L (15.1%) | L5 | Rejected-Finance Higher bid value |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
6 Jan 2022, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
ADDN / ALTN TO OVERHEAD ELECTRIC WIRING T UNDERGROUND CABLES IN APS INCLUDING CERTAIN MINOR WORKS UNDER GE DINJAN
2021_MES_491643_2
C/8362/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹41,000
Yes
12 Feb 2022
23 Dec 2021
8 Jan 2022
23 Dec 2021
6 Jan 2022
31 Dec 2021
Amount
M&L for LED underwater waterproof wall mounted grouted swimming pool brigth white light 18W LEDwith driver with solid SS stainles steel / aluminium concealed type LED underwater pool lights 18 LED 30/36W IP68 waterproof, round with front self mounted flange, LED lens with 1m cable and gland IP68 nickel coated. Light to be chemically glue potted complete with LED driver unit for watch light with 10 Kva spike guard, over voltage protection, input voltage 190-265 VAC including 3 runs of 1.5 sqmm multistranded copper conductor complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches/ along poles, under floors, through GI pipe complete all as specified and as directed. Note : (1) Protection pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 70 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Protection pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 185 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Protection pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
M&L in repairs earthing with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
Dismantling cross arms of M.S. channel or angle sections etc. complete and stacking aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work complete all as specified and as directed.
Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and as directed.
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size any type from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and as directed
Dismantling existing unserviceable GI earth wire, cradles of any type from service feeder or distributor span complete all as specified and as directed.
Earth continuity conductor fixed to wall on batten or recess or chases or burried in ground or drawn in coduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required galvanised GI Strip 32 x 6 mm by making a common grid connectivity complete all as specified and as directed
M&L for cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for galvanised steel earth wire 4 mm dia (hexagonal/rectangular) used for craddle guarding suitable for LT/HT over head line complete all as specified and as directed.
S&F in repairs modular junction box made of SMC/FRP of size 250x200x105mm with MCB SP, 6-32A, 10 KA, 'C' Curve, 01 No and connector terminal 4 pole indicating RYB Phase Colour and Neutral colour complete fixed to street light pole with suitable size of mild steel clamps, nuts & bolts complete all as specified and as directed. Make : Cat No : GSJB 1414 of Sintex / Hensel.
S&F for three core of single run copper cable PVC insulated, pvc sheathed flexible stranded copper cable FRLSH suitable for outdoor use 1.5 sqmm PVC single core PVC Sheathed from light fitting terminal to junction box including PVC conduct heavy duty with supporting clamps etc complete all as specified and as directed.
S&F for three core of single run copper cable PVC insulated, pvc sheathed flexible stranded copper cable FRLSH suitable for outdoor use 2.5 sqmm PVC single core PVC Sheathed from light fitting terminal to junction box including PVC conduct heavy duty with supporting clamps etc complete all as specified and as directed.
Supply, install, testing and commissiong in replacement of double door type outdoor LT Feeder Pillar Box pedestal type totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made out of 3.15 mm thick CRCA sheet steel for load bearing protection of enclosure IP-54 complete hinged door with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work supports, excavation and earth work, PCC foundation etc, cubical type as required with and including the following, supplied fitted and connected internally complete (a) 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 300 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators complete all as specified and as directed.
M&L for 80 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
Surface dressing not exceeding 15cm deep and and getting out in soft/loose soil complete all as specified and as directed.
M&L for hardcore of gauge of broken stone or boulders not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick, plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) complete all as specified and as directed.
M&L for 40 mm thick, plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in floors and finishing cement concrete surface even and smooth using extra cement complete all as specified and as directed.
M&L for chequered cement concrete tiles of size 25cm x 25cm x 20mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:6 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
Point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FR PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed.
All as per item No 28 above but with 4 Sqmm complete all as specified and as directed.
All as per item No 28 above but with 2.5 Sqmm complete all as specified and as directed.
S&F for switch socket combination 2-in-1, 5 pin 15 Amps, flush type complete all as specified and as directed.
S&F for switch piano 5 Amp single pole, flush type one way complete all as specified and as directed.
S&F for ceiling rose 3 way PVC insulated body complete all as specified and as directed.
S&F for exhaust fan AC single phase 230/240 V of size 380 mm sweep 1 Phase 1400 RPM including LOUVER SHUTTER of suitable size complete all as specified and as directed. Make : Model No EXHD380-4-1 of Crompton/Bajaj/Havells.
M&L for cutting/making hole for fixing of exahust fan as per size and making good disturbed surface with existing surface complete all as specified and as directed.
STANDARD ELECTRIC WINDERS
MAZUMDAR ENTERPRISE
FREEZCON
M/S AUTOMOTIVE WORLD
M/s. R. K. Trading Company
M/s GANDHESWAR PHUKAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .