| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | ₹10.4 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹10.7 LRejected-AOC 139 NEW GOLDEN AVENUE NEAR PANJ PEER AMRITSAR PUNJAB | ₹10.7 L | L2 | Rejected-AOC Being Highest |
| Sl No | Description | Qty | Unit | JP ENGINEERING WORKS L2 | KAMALJIT GOVT CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00Laying of PVC Underground Pipe Line 200 mm dia of T/Well Village Algran of Shri Anandpur Sahib Block | |||||
| 2.00 | Dag Belling double kassi stroke V-Shape minimum 10 cm depth. | 2.25 | KM | 1,950 ₹3,178.50 | 1,915 ₹3,121.45 |
| 3.00 | Exacavation by mechanical means (JCB or Hydrulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming. Earth work excavation trimming and dressing of sides, leveling of beds of trenches to correct grade, cutting joint holes, refilling, consolidation, watering, including the cost of dewatering of rain water,Diversion for traffic, nightsignals. Providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing etc.and removal of surplus soil outside/inside the town involving lead upto 15mtr. complete in all respect. In all classes of soil except rocky. | 1,509.75 | CUM | 130 ₹1.6 L | 120 ₹1.5 L |
| 4.00 | Laying, fixing and jointing of PVC Pipes as per ISI 4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specification . 200 mm o/d pipe of 2.5 kgf./sqcm including 94 kms cost of carriage,loading and unloading from Goraya store to Algran site for the departmental procured pipes | 2,250 | MTR | 222 ₹3.6 L | 226 ₹3.7 L |
| 5.00 | Suppling, carriage and fixing PVC Bend size 200 mm Ф,4 kgf/sqcm, 1.5 mtr length of 90 degree | 10 | No | 550 ₹11,000 | 530 ₹10,600 |
| 6.00 | Suppling, carriage and fixing PVC Bend size 200 mm Ф, 4 kgf/sqcm, 1.5 mtr length of 45 degree | 8 | No | 500 ₹3,000 | 470 ₹2,820 |
| 7.00 | Suppling, carriage and fixing PVC Bend size 200 mm Ф, 4 kgf/sqcm, 1.5 mtr length of 30 degree | 8 | No | 850 ₹6,800 | 800 ₹6,400 |
| 8.00 | Suppling, carriage & fixing equal PVC Tee pressure 4 kgf/Cm², 200x200x200mm | 6 | No | 530 ₹2,120 | 500 ₹2,000 |
| 9.00 | Cost of One No. Riser (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) of 200mm dia as per approved drawing & Design unit each (Departmental Supply) | 24 | No. | 2,600 ₹39,000 | 2,500 ₹37,500 |
| 10.00 | Providing and Making outlet Khura (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) at riser point complete in all respect as per approved design/drawing 200 mm dia.(Departmental Supply) | 24 | No. | 14,500 ₹2.2 L | 13,600 ₹2.0 L |
Updated dates
Tender Value
₹15.7 L
EMD Value
₹32,000
Closing Date
24 Feb 2026, 10:00 amClosed
Divisional Engineer
Divisional Engineer BDC-1 PWRMDC Division SYL Shed No 02,Near Nehru Stadium Ropar
LAYING OF UNDER GROUND PVC PIPE LINE OF 1 NO. DEEP TUBEWELL AT VILLAGE- ALGRAN OF SHRI ANANDPUR SAHIB BLOCK IN DISTRICT RUPNAGAR (Under 502 No. Deep Tubewell Scheme)PART-B
2025_WR_152498_3
38/2025/BDC-1/Ropar
Open Tender
Civil Works
180 days
Shri Anandpur Sahib Block
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
₹32,000
Yes
16 Mar 2026
19 Jan 2026
24 Feb 2026
19 Jan 2026
24 Feb 2026
19 Jan 2026
Laying of PVC Underground Pipe Line 200 mm dia of T/Well Village Algran of Shri Anandpur Sahib Block
Dag Belling double kassi stroke V-Shape minimum 10 cm depth.
Exacavation by mechanical means (JCB or Hydrulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming. Earth work excavation trimming and dressing of sides, leveling of beds of trenches to correct grade, cutting joint holes, refilling, consolidation, watering, including the cost of dewatering of rain water,Diversion for traffic, nightsignals. Providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing etc.and removal of surplus soil outside/inside the town involving lead upto 15mtr. complete in all respect. In all classes of soil except rocky.
Laying, fixing and jointing of PVC Pipes as per ISI 4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specification . 200 mm o/d pipe of 2.5 kgf./sqcm including 94 kms cost of carriage,loading and unloading from Goraya store to Algran site for the departmental procured pipes
Suppling, carriage and fixing PVC Bend size 200 mm Ф,4 kgf/sqcm, 1.5 mtr length of 90 degree
Suppling, carriage and fixing PVC Bend size 200 mm Ф, 4 kgf/sqcm, 1.5 mtr length of 45 degree
Suppling, carriage and fixing PVC Bend size 200 mm Ф, 4 kgf/sqcm, 1.5 mtr length of 30 degree
Suppling, carriage & fixing equal PVC Tee pressure 4 kgf/Cm², 200x200x200mm
Cost of One No. Riser (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) of 200mm dia as per approved drawing & Design unit each (Departmental Supply)
Providing and Making outlet Khura (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) at riser point complete in all respect as per approved design/drawing 200 mm dia.(Departmental Supply)
Providing and fixing Pressure air release pipe 200mm dia. (PVC pipe of 2.5 kgf/sqcm pressure and fitting of 4 kgf/sqcm) as per approved design/drawing. (Departmental Supply)
Suppling & carriage of RCC spun pipe with rubber ring as per I.S:458-2003( pipe for road crossing)Class N.P.2. 250mm dia.
Suppling, carriage and fixing PVC coupler 200mm i/d ,4.0 kgf/cm²
Suppling, carriage and fixing PVC end cap 200mm I/D, 4.0 kgf/cm²
Const. of pipe stand with RCC 600 mm dia pipe complete in all respect as per drawing/design and PWD specification .
Making Grade Breaker as per desing/drawing and PWD specification( including the cost of Material carriage & re-carriage at site of work). without the cost of PVC pipe, fitting and solvent cement (SOR)(200 mm dia PVC pipe 2.5 kg/sqcm Departmental Supply)
Providing & fixing C.I/D.I flanged end , stem of SS (AIS 1410) & Bronze ( gunmetal) working parts sluice valves ISI maked 14846-2000 , including jointing. Testing & cost of Nut, bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge) .Class PN-1 as per ISI 200mm i/d Sluice Valves flanged and Const. of masonary sluice valve chamber excluding sluice valve cover as per Standard Design & Drawing of Public Health Dept. Size 0.9m x 0.9m.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
NIT38.pdf
Tender Documents • 0.24 MB
DNIT38.pdf
Tender Documents • 2.30 MB
BOQ_320638.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid