GE (N) Bikaner
GE (N) Bikaner Raj 334001
REPAIRS TO ROOFS TREATMENT, CHAJJA, WATER PROOFING, PLASTERING AND MISC WORKS IN ZONE-C IN THE AREA OF AGE BR-II AT MIL STN BIKANER UNDER GE (N) BIKANER
2026_MES_798719_1
GE (N) BKN-TOKEN-63 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
Bikaner Station Bikaner
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE (N) Bikaner
₹98,000
Yes
14 Nov 2026
14 Nov 2026
10 Dec 2026
14 Nov 2026
3 Dec 2026
28 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, exc 250 ltrs but not exc. 500 ltrs cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning and replacement of float valve and tank nipple if required complete all as specified and directed. | 70 | Each | - | - |
| 2 | Disconnecting existing tanks exc 500 ltrs but nexc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning and replacement of float valve and tank nipple if required complete all as specified and directed. | 60 | Each | - | - |
| 3 | M&L for 15mm to 20mm thick screed bed in cement mortar 1: 4 on concrete surfaces, finished Fair & even with and including mixing water proofing compound as per manufacturer's instruction complete all as specified and directed.
(Note :-Rate of Water proofing liquid deemed tobe included in quotaed rate of item) | 575 | Sqm | - | - |
| 4 | M&L for Roof treatment in as specified below and as directed:
(a) Removal of existing PCC/Brick bat Coba/Mud phuska/ APP membrane from the roof stacking the reusable material and disposal of unserviceable rubbish outside the campus as direction by Egineer-in-Charge but outside in 3 km.
(b) Cleaning of surfaces of loose dust, and dirt and cement slurry etc, by means of wire brush, dust removing brush andscraper etc, pot holes/cracks shall be repaired with cement admixed with polymer as per manufacturer instructions. Proving PCC coping/gola along vertical parapets of size 75 mmx 75mm with concrete mix (1:2:4) type B-1 using water
(c) Water proofing compound of approved make etc, complete as directed by engineer in charge.
(d) Repair of surface with GP-2(General purpose Grout) or repair mortar as and where required as per site
condition/manufacturers instruction up to 15 mm thick and including cracks shall be repaired with cement admixture with polymer as per manufacturers water proofing coating in white colour, anti-fungal, anti-algae, resistance to water and ageing.excellent UV resistant having facturers instructions M&L for applying fibre reinforced, single component, elastomeric liquid applied and a reflective index more than 105, with PU hybrid polymers and reinforcing acrylic fibres, elongation greater than 300% and applied in three layer complete all as follow:-
(a) Preparation of surface by cleaning and removing loose particles then finst coat of liquid water proofing after diluting as per manufacture instruction as a primer and allow the surface to dry for minimum 10 to 12 hours complete all as specified and directed
(b) Applying second coat of liquid water proofing without dilution on the primed surface and time to dry the surface for minimum imum 10 to 12 hours complete all as specified and directed.
(c) Apply third coat of liquid water proofing without dilution over the second coat and allow minimum 48 hours complete complete all as specified and directed.
NOTE (1) The work shall be carried out by authorized applicator only contractor will submit MoU with authorised applicator of manufacturer before excecution of work.
(ii) Material incorported in the work shall be calculate as per site requirement and full quantity of material shall be brought at site before execution of work.
(iii) Necessary guarantee for 10 years shall be submitted by the contractor.
Make :- Asian/Fosroc/DrFixit/Pidilite/Sika | 575 | Sqm | - | - |
| 5 | M&L for demolition of sunken filling concrete, removal of loose concrete and cleaning the surface and after proper cleaning filling the Sqr cracks with polymer modified morter using Dr Fixit pidicrete URP and providing 50mmx50mm angle filets on the vertical upstands, wall junction comer, properly dressed by preparing polymer modied morter with Dr Fixit pidicrete URP in the ratio of 1:3 by adding polymer 10% by weight of the cement, add water as required. thereafter providing and applying two coats of acrylic polymer modified cementitious coating Dr. Fixit pidiflin 2K of Mis Pidilite Industries having elongation at break 50% 5 bar resistance to positive water pressure, adhesive strength ASTM D 7234-1 N/mm sq, water vapour transmission as per ASTM E96 of 030 perms and crack bridging ability as per EN 1062-7 up to 1mm. Apply two coat of Dr Fixit pidifin 2K slurry, coverage of 0.55-0.58 sqmvkg of mix slurry, provide and lay 45 gam glass fibre mesh over the angle fillet when the first coat is still wet. Allow the first coat to dry for 6-8 hours, then apply the second at a direction perpendicular to first coat. Allow the coating to air cure for 5 days before conducting water ponding teat for 24 hrs etc or other equivelent product as approved by GE Complete all as per manufacture instruction, including removing rubbish material from from building and thrown in low lying empty area at any distance out side MD land, complete all as specified and as directed | 150 | Sqm | - | - |
| 6 | M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile n exceeding 0.06 sqm but not exceeding 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match match the shade of tiles laid over and including 15 mm thick screed bed in cement mortar 1:4 including dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed. | 150 | Sqm | - | - |
| 7 | M&L coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 300 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & incl.10 mm thick rendering in CM 1:4, including dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed. | 300 | Sqm | - | - |
| 8 | S&F in repairs vitreos china wash down water closet pan white ( excluding cistern and flush pipe) with WC seat & cover white colour closed pattern with flat bottom complete all as specified and directed. | 15 | Each | - | - |
| 9 | Taking down and Re Fixing in repairs vitreos china wash down water closet pan (EWC) any type complete all as specified and directed. | 15 | Each | - | - |
| 10 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. | 15 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tender63.pdf
Tender Documents • 1.44 MB
BOQ_896035.xls
BOQ • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .