| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹15.4 L+₹94,279.50 (6.52%)Rejected-AOC | L2 | Rejected-AOC Rejected not being lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
29 Oct 2021, 5:00 pmClosed
CWE No 2 Meerut
Headquarters Commander Works Engineer No 2 Military Engineer Services Boundary Road, Near Supply Depot Meerut Cantt-250001
REPAIRS/ MAINT TO HT/LT OVERHEAD LINES, UNDERGROUND CABLES, PANELS, DEHYDRATION OF TRANSFORMER AND MAINT OF TRASFORMERS, VCBs AND CONNECTED E/M WORKS AT RTS D SAHARANPUR UNDER GE ROORKEE
2021_MES_468428_2
95125/RKE/E8
Open Tender
Civil Works
Item Rate
120 days
Roorkee
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Roorkee
₹30,000
Yes
13 Nov 2021
22 Sept 2021
1 Nov 2021
22 Sept 2021
29 Oct 2021
15 Oct 2021
Amount
Disconnecting defective transformer indoor/outdoor of capacity 400KVA both from HT/LT sides, and then drainage of complete transformer oil, opening of top cover with due care and removal of all HT/LT winding connections from bushing and then lifting of core by means of tripod and chain pulley with due care for inspection and ascertain it’s serviceability state after keeping it aside. Removal of all sludge and unwanted material from tank and core, lowering of core assembly after carrying out required repairs to the winding and core. In case the repairs which are not possible at site then the transformer has to be taken to the work shop for repairs, and installation back to original position after repairing and connecting, testing complete all as directed at site by Engr-In-Charge. Note :- (i) The cost of transportation shall be deemed to be included in the quoted rate by the conractor. (ii) The cost of rewinding shall be paid separately. (iii) The cost of dehydration/filtration & other necessary repair as directed shall be measured & paid separately under relevant items of this schedule. (iv) Additional transformer oil for top-up, if required will be filled by contractor and shall be paid under respective item of this schedule.
Disconnecting defective transformer indoor/outdoor of any capacity up to 160-250KVA both from HT/LT sides, and then drainage of required transformer oil. Opening of top cover LT and HT side bushings with due care and removal of all HT/LT winding connections from bushing and then replacement of head gasket, LT and HT bushing packings complete and ensured that no leakage in transformer from LT/HT bushing and top cover gasket as directed by Engr-in-Charge.
Disconnecting defective transformer indoor/outdoor of any capacity up to 25-100KVA both from HT/LT sides, and then drainage of required transformer oil. Opening of top cover LT and HT side bushings with due care and removal of all HT/LT winding connections from bushing and then replacement of head gasket, LT and HT bushing packings complete and ensured that no leakage in transformer from LT/HT bushing and top cover gasket as directed.
Taking down of transformers of capacity25/63/100 KVA from 2/4pole structure or from PCC platform with due care after disconnecting all HT/LT connections on pole mounted structures, Transportation of transformer to workshop from site of installation to workshop for repairs including loading and unloading of transformer, and replacing it to site from where it was taken for repairs as per site requirement and then lowering it by means of crane and remounting on 2/4pole structure after repairs with all connection complete all as directed and specified.
Shifting of transformers of capacity 25/63/100/160/250/400 KVA from 2/4pole structure or from PCC platform with due care after disconnecting all HT/LT connections on pole mounted structures, Transportation of transformer to PCC/ 2 or 4 pole structure to any other required location at RTS & Depot , Saharanpur lowering and remounting on 2/4pole structure it by means of crane after disconnecting all connection and reconnection in new location including earthing connection and as directed.
S & F in replacement of worn out HT copper coils made out of super enamelled insulated copper wire all as per existing size and shape including all insulating, binding, material and then varnishing complete all as specified and directed.
M & L for replacement of worn out LT copper coils made out of super enamelled insulated copper strip all as per existing size and shape including all insulating, binding, material and then varnishing complete all as specified and directed.
Dehydration/centrifuging of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition of transformer including testing of transformer oil before and after centrifuging from top and bottom of transformer at 4mm gap the break down voltage should be 50KV complete all as specified and directed.
Supply and topping up of transformer oil of dielectric strength of 65 KV complete all as specified and directed.
Material and labour for replacement of worn out bushing rod made out of brass with heavy duty three nuts and three washer at both ends suitable for HT side all as per exiting size, shape and length suitable for following capacity transformers :- (i) 160 – 250 KVA Transformers.
(ii) 400 KVA Transformer.
(iii) 25 - 100 KVA
M & L for replacement of worn out bushing rod made out of brass with heavy duty three nuts and three washer at both ends suitable for LT side all as per existing size, shape and length suitable for following capacity transformers :- (i) 160 – 250 KVA Transformers.
(ii) 400 KVA Transformer.
(iii) 25 - 100 KVA
M & L for replacement of worn out porcelain bushing for 11KV HT side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by Engineer in Charge suitable for following capacity transformers:- (i) 160 – 250 KVA Transformers.
(ii) 400 KVA Transformer.
(iii) 25 - 100 KVA
M & L for replacement of worn out porcelain bushing for .433 KV LT side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by Engineer in Charge suitable for following capacity transformers:- (i) 160 – 250 KVA Transformers.
(ii) 400 KVA Transformer.
(iii) 25 - 100 KVA
M & L for replacement of worn out rubberised cork sheet 4mm thick for transformer top cover all as required at site and as directed by Engineer in Charge suitable for following capacity transformers:- (i) 160 – 250 KVA Transformers.
(ii) 400 KVA Transformer.
(iii) 25 - 100 KVA
M & L for replacement of worn out rubberised cork sheet 4mm thick suitable for HT/LT side bushing of off sizes all as required at site and directed by Engineer in Charge.
M & L Preparation of old surface of transformer for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of transformer complete all as specified and directed by Engineer in Charge suitable for following capacity of transformer:- (Note for Sl No-16 colour code of transformer :- (i) Body - Smoke grey (ii) Vent pipe, drain plug - Red (iii) Base plate/C-section, iron wheel -Black (iv) Writing MES/SM No - White) (i) Upto 160 KVA.
(ii) 400 KVA
M &L for replacement of worn out silica gel breather in transparent body all as per existing sample suitable for following capacity of transformers of any make.:- (i) 160 – 250 KVA.
(ii) 400 KVA
(iii) 25 - 100 KVA
Material and labour for replacement of unserviceable off load tap changer assembly all as per existing sample suitable for following capacity of transformers of any make.:- (i) 160 – 250 KVA.
(ii) 25-100 KVA
M & L for oil temperature gauge /thermometer suitable for transformers all as per existing shape and size for any make and model transformers all as specified and directed by Engineer in Charge.
Supply, testing, jointing and commissioning of Cold shrinkable type straight through joint kit and incl jointing materials suitable for cable size 50 to 95 sq mm 3 Core X LPE 11 KV cable complete all as spd and directed . Make- Raychem/ Dension/ Mseal
Supply, testing, jointing and commissioning of indoor Heat shrinkable end tremination joint kit and incl jointing materials suitable for cable size 50-95 sq mm 3 Core X LPE 11 KV cable complete all as spd and directed . Make- Raychem/ Dension/ Mseal
Supplyk, testing, jointing and commissioning of outdoor heat shrinkable end tremination joint kit and incl jointing materials suitable for cable size50- 95 sq mm 3 Core X LPE 11 KV cable complete all as spd and directed . Make- Raychem/ Dension/ Mseal
Supply, testing, jointing and commissioning of outdoor Heat shrinkable end tremination joint kit and incl jointing materials suitable for cable size 70-95 sq mm 3 Core X LPE 11 KV cable complete all as spd and directed . Make- Raychem/ Dension/ Mseal
S&F as in replacement of Digital protective relays comprising of 3 Phase over current plus earth fault relay with high set operational with 24 volt to 110 volts AC / DC, including its calibration by using Primary/Secondary injection of the existing make including complete wiring with suitable size wire Relay make & Model No. Schineder P-122 and fixing arrangement complete as specified and directed.
M&L for as in replacement of tubular battery of 150 AH, 12 Volts capacity for 11 KV VCB, rating 630 Amp make ABB.
M&L for as in replacement of HRC fuses of PT of existing make for 11 KV VCB, rating 630 Amp, Make ABB.
M&L for as in replacement of Current Transformers of existing make for 11 KV VCB rating 630 Amp, Make : ABB.
M&L for as in replacement of Multifunction meter, all as per legrand model No PMX 7000 or equivalent in L&T /HPL/ Schineider
M&L for as in replacement of spring Charging motor of VCB working on 24 Volts DC supply and operated as per existing torque and RPM (630 Amp rating 11 KV VCB) Make: ABB.
Testing and calibration of existing Micro processor based digital programmer Protection relay unit having over current handling capacity up to 10 Amps for 10 milli sec and Earth fault arrest less then 04 milli sec to arrest the fault of individual VCB and by using primary and secondary injection at site complete all as specified and directed by Engr-in-Charge.
S & F air break switch triple pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts, and washer etc. Synthetic bounded fuse carrying tube complete with flip mechanism suitable for current carry capacity upto 200 Amps all as directed. ( set of three)
Supply only tinned copper fuse wire of capacity (22 SWG ) 10-60 Amp for drop out fuse all as specified.
Supply only electrical Rubber hand gloves, 11KV, ISI mark
S & F vertical type air break gang operated triple pole, mechanically operated, outdoor type with all fittings, accessories, mounted on and including HT 11 KV porcelain insulators and steel channel frame GI Operating rod 25 mm dia of suitable length worked from ground including locking arrangements, with 7 livers Naval brass lock, suitable for 200 Amps current rating complete.(set of three)
Supply and laying in replacment of synthetic rubber insulated mats 2.5mm thick for voltage upto 11 KV (Size 2 x 1m) all as specified and directed
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in HT/LT underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed
Returning, filling, spreading, levelling, watering & well ramming in layers n.exc 25 cm thick as in soil complete all as specified and directed.
Removing excavated soil exc 50 mtr and depositing as directed n.exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for dry clean Sand filling in trenches around underground cables for cushioning, complete all as specified and directed. Note: Depth of sand shall be measured after punning complete all as specified and directed.
Supply and laying in replacement of reinforced precast cement concrete cable cover class HV, flate size 300 X 180 X40mm complete as specified and directed
M&L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in Coping of pole/Stay etc. including necessary form work for coping and finished the surface even and fair complete all as specified and directed at site.
M&L for PCC 1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of PCC poles/struts all as specified including necessary form work all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
S & F for High tension cable fault checking by high tension cable fault testing machine by disconnecting the HT cable end termination including insulation testing complete of faulty cable complete all as specified and directed
S & F in replacement of aluminium conductor, steel reinforced off sizes including binding wire and jumper connect with PG clamp made out of aluminium alloy according to IS-617 complete all as specified and directed by Engr-in-Charge.
Supply and fix HT 11 KV outdoor expulsion type lightening arrestor with all fittings, transmission class, discharge capacity 65 kilo Amp with the provn of mountings, accessories complete fixed on cross arms of two/four pole structure/GI flat strip and connect with same size of ACSR conductor encased in PVC alkathine pipe with all fittings connected to earth strip with nut, bolt, washer all as specified and directed complete.
Supply only HT Insulation tape roll all as specified.
Taking down unserviceable steel tubular poles at site as directed by Engr-in-charge
Supply and erect in true vertical (or to be planted as strut) steel tubular, swaged welded pole complete with MS base plate of 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolts, nuts, washer and screws confirming to IS -2713 Part II type 410-SP-55 (11 mtr long) hole of required size and Nos for fixing cross arms painting with one coat of red oxide primer and two coats of silver aluminium paint for exposed surface and two coats of black bituminous paint for portion embedded in concrete complete all as specified and directed (Note : Excavation earth work, PCC foundation, coping shall be measured and paid separately).
Disconnecting and taking down unserviceable 11 KV UG Cable of any size and capacity
Supplying, Laying & testing cable XLPE insulated screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size through pipes in ducts, poles/ trenches including fixing of aluminium lugs, making good to disturbed surface etc for the following cross sectional area, complete the following as specified and directed 95 Sqmm 3 core :- Make:- Grandlay/Havells/Polycab (Note : Excavation and earth work to be measured and paid separately)
S&F as in replacement of Anti climbing devices; spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers, and welding in two halves made to shape to suit the cross section of the pole.
S & F in replacement of unserviceable danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figure and conventional skull and bone signal in red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 25x20 cm Size
S & F in replacement of unserviceable Guardiing Cradles,hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia
S&F potential transformer suitable for VCB 630 Amps, Accuracy class 1.0 of make : ABB earthed type, 11000/V3/110/V/110/V3-110/3V
Supply & fixing VCB spout, made of epoxy resin suitable for ABB 11 KV VCB 50 HZ, 630 Amp, consists of two numbers spouls, one for panel fix and other for movable VCB trolley, complete all as specified and directed by Engr-in-Charge. Make of the spout : sutaible for ABB make VCB as directed by GE.
Taking out 11 KV VCB make ABB trolley from the panel for servicing to the workshop, Cleaning off the carbon from the trolley with chemical compound and replacement of following defective items all as specified and directed and after repairs checking the trolley for its fitment in the VCB panel to the entire satisfaction of GE/ Engr-in-Charge :- (i) Vacuum Interrupter cylinders - 1 Nos (ii) VCB trolley insulatros - 2 Nos (iii) Aluminium HT legs connectors - 1 Nos (iv) VCB Jaw contact - 1 Nos (v) VCB trolley epoxy resin housing - 1 Nos. Note : Contractor shall visit the site before quoting rates for the above item to assess the nature of repairs.
M & L for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
Labour only for stringing, tightening, fixing and connecting ACSR conductor and GI Wire of existing HT/LT overhead line any size any type, between pole to pole, approximate span length 40 to 50m, complete the following all as specified and directed : - (i) 2 Wire with/Without GI Wire.
(ii) 5 Wire With GI Wire.
(iii) 6 Wire With GI Wire.
M & L for Earthing complete with galvanized steel earth plate electrodes 60x60x6 mm thick buried directly in ground eath (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanized iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified &shown in electrical plate No.3 of MES SSR part-I connected to earth test point as specified as specified and testing on completion including provision of 40 mm dia light grade pipe & watering pipe shall be 20 mm bore meadium grade including all excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including chrcoal , salt funnel GI pipe 40 mm dia light grade up to to 7.5 mtr length ,all as directed at site.
M&L for Painting single pole or struct of LT PCC poles/structure including. cleaning and scrapping the old surface and then applying two coat of light grey synthetic enamel paint to complete pole and two coat of aluminum synthetic enamel paint over a coat of red oxide on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc and including painting of pole/ structure with two coat of synthetic paint yellow & Black strips 300mm wide alternative from bottom to upward of LT pole upto height of 1.5mtr above embedded portion at GL, and writing pole number, complete the following as specified and directed by EIC.
M&L for Painting of single LT steel tubular, structure including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :- Notes for Item No 61 to 6 : - (i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface. (ii) All poles will be numbered all as directed at site. (iii) If painting of poles not properly and not satisfied by JE/Engr-in-charge shall not be paid to contractor or otherwise repaint without extra cost.
M&L for Painting of single HT steel tubular, structure including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & maroon enamel paint strip 300 mm wide alternative from bottom to upward of HT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :- Notes : - (i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface. (ii) All poles will be numbered all as directed at site. (iii) If painting of poles not properly and not satisfied by JE/Engr-in-charge shall not be paid to contractor or otherwise repaint without extra cost.
Supplying, Laying, Jointing, testing and commissioning cable XLPE insulated armoured LT 1100 grade heavy duty with Stranded aluminum conductor through pipes in ducts, poles/ trenches including fixing of copper lugs, making good to disturbed surface etc for the following cross sectional area, complete the following as specified and directed :- Make:- Grandlay/Havells/Polycab (Note : Excavation and earth work to be measured and paid separately) (i) 10 Sqmm 2 core
(ii) 25 Sqmm 3.5 core
(iii) 35 Sqmm 3.5 core
(iv) 50 Sqmm 3.5 core
(v) 70 Sqmm 3.5 core
(vi) 95 Sqmm 3.5 core
Taking down GI tubing light grade of sizes 50/40 mm dia from trenches/floor/walls/poles, complete all as specified and directed. (Note : Excavation will be measured and paid separately).
S&F GI tubing 50mm bore light grade for cable protection fixed on pole/laid under floor / road/wall etc with fittings including necessary flat iron clamps of size 40 x5 mm etc complete all as specified and directed.
S&F GI tubing 40mm bore light grade for cable protection fixed on pole/laid under floor/wall etc with fittings including flat iron clamp 40 x 5 mm complete all as specified and directed.
M&L for replacement of unserviceable/ damaged PVC jumper for HT/LT of any size and length to transformer or pole for making connection, complete all as specified and directed.
S&F aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
M&L for cutting PCC/floor/road and taking out cable and making good with PCC including material as per existing after laying of pipe for cable protection complete all as specified and directed at site of trench not more than 0.30 x 0.30m, complete all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, 10 x 2 core cable flat or circular complete all as specified and directed.
Taking down MCCB of any capacity and size, complete all as specified and directed.
S & F MCCB 400 Amp 4 pole 36 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4202 07/ Siemens/ Schneider
S & F MCCB 250 Amp 4 pole 36 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4202 19/ Siemens/ Schneider
S & F MCCB 200 Amp 3 pole 36 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4202 08/ Siemens/ Schneider or equivalent
S & F MCCB 160 Amp 4 pole 36 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4200 17/ Siemens/ Schneider or equivalent
S & F MCCB 100 Amp 3 pole 16 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4200 15/ Siemens/ Schneider
S & F MCCB 63 Amp 4 pole 16 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4200 13/ Siemens/ Schneider
S & F set of incoming or outgoing spreaders 4P complete all as specified and directed. Make;- Legrand catpart No 4200 13/ Siemens/ Schneider
M&L for repairing LT feeder box/ panel and their doors, inner compartments etc by denting/ welding where required and cleaning, removing old paint by paint remover/scrappers for any number of coats, any width or girth and applying two coats of synthetic enamel paint by spray painting, inside and outside of panels(second coat shall be applied at the interval of one day) of the approved colour, complete all as specified and directed.
S & F for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones signal in red colour and fixed with M.S. Clamp 25X3mm, suitable for PCC/Steel tubular pole, bolts and nuts of approved size for LT 20x15 cm size complete.
M & L for spreading stone aggregate of size 40mm at 11 KV sub station/Transformer/panel board/two pole/four pole structure area, complete all as specified and directed.
S&F in replacement LED type Indicating lamps for LT panel, RYB colour, complete all as specified and directed.
S & F new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 45 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make:- Cat Part No LTESS45WLED/LS of C&S or equivalent in Havells/CG/Phillips
S & F new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 25 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make:- Cat Part No LTESS25WLED/LS of C&S or equivalent in Havells/CG/Phillips
S & F in repair for swich disconnector fuse unit in sheet steel enclosure TPN current rating 160 Amp with HRC Fuse including disconnecting and taking out U/S Main switch complete all as specified and directed.
S & F in repair for swich disconnector fuse unit in sheet steel enclosure TPN current rating 100 Amp with HRC Fuse including disconnecting and taking out U/S Main switch complete all as specified and directed.
S & F for pin insulator porcelain type vitreous white brown including one galvanized mild steel spindle two galvanize iron washers and one galvanized iron nut 100 mm height, 65mm dia for 1100 V grade, complete all as specified and directed.
S & F for shackle type porcelain vitreous white, brown including one galvanized mild steel straps, washers, bolts and nuts 100 mm height, 115 mm dia, section of strap 31 x 5 mm for 1100 V grade, complete all as specified and directed.
Dismantling unserviceable insulators any type, any size, complete all as specified and directed.
S & F in repair for LT line PVC Spacers spiral type for the following :- (i) Spacer for two wire
(ii) Spacer for three wire
(iii) Spacer for four wire
Dismantling/taking out old unserviceable LT of PCC/Steel poles after breaking the PCC foundation and clearing the site/premises complete all as specified and directed.
Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts , nuts and screw as specified of type 410 SP-31, 9 Meter long, including marking alternate yellow and black strips 30 cm height- total-5Nos with two coats of aluminium paint over a coat of zinc chrome primer above embedded portion at GL, complete all as specified and directed. (Note. Earth work and PCC for foundation channels, clamps, nuts and bolts to be measured and paid for separately)
S & F for galvanised steel wire 4 mm dia to be stringed as continuous earthing wire on over head LT lines complete all as directed incl taking down the old rusted earth wire.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified.
S & F for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all as specified and directed by EIC.
Supply and fixing in repairs stay assembly for LT Pole comprising of 7/3.15mm galvanized steel stranded stay wire of required length fixed to pole with and including clamps fabricated out of MS Clamps 50 x 6 mm flat iron including nuts, bolts and washers, MS galvanized stay bow 14mm dia 400mm long galvanized steel stay rod 16mm dia, 1800mm long with ratchet type nuts & bolts and stay plate, galvanized thimble 02 Nos, loop insulators 65mm x90mm clearance dia of hole 16mm all as specified and shown in electrical plate No. 1 of MES SSR including all necessary excavation and earth work, PCC (1:3:6) type C-2 using 40mm graded stone aggregate ,embedded block and disposal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed by EIC.
M & L for Earthing complete with galvanized steel earth plate electrodes 60x60x6 mm thick buried directly in ground eath (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to GI wire 4mm by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I connected to earth test point as specified as specified and testing on completion including provision of 20 mm dia light grade pipe & watering pipe shall be 15 mm bore meadium grade including all excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including chrcoal, salt & funnel GI pipe 20 mm dia light grade up to to 7.5 mtr length ,all as directed at site.
Repairs to existing stay assembly including tightening of stay wire, , shifting of clamps fixed to pole or by repairing to PCC coping by breaking and making new with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and directed at site .
S & F in replacement of unserviceable can type resin filled (Alpx3) capacitors with built-in terminal connectors on top and mounting stud on the bottom heavy duty 440 V Un all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand/Epcos/Universal (i) 25 KVAr
(ii) 15 KVAr
(iii) 10 KVAr
(iv) 5 KVAr
S & F in replacement of unserviceable digital power factor controller 4/6 step type with provision of manual and automatic mode operation conforms to IEC 61010-1, high accuracy, IP 41 terminals with manual and automatic mode ooperation all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make.: Legrand/Havells/L&T
S & F in replacement of unserviceable capacitor switching unit capcitor duty contactor consisting of mounting block and contactors, for switching capacitors, suitable to be installed directly on 3 pole, 9 to 40 A contactors all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand CTX3-series equivalent in Havells/L&T
S & F in replacement of unserviceable capacitor switching unit capcitor duty contactor consisting of mounting block and contactors, for switching capacitors, suitable to be installed directly on 3 pole, 50 to 65 A contactors all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand CTX3-series equivalent in Havells/L&T
S & F in replacement of unserviceable three pole MCB 32 Amp all as per existing make suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand DX3 cat part No. 4087 65 or equivalent in Havells /L&T
S & F in replacement of unserviceable three pole MCB 32 Amp all as per existing make suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. make : Legrand DX3 cat part No. 4087 65 or equivalent in Havells /L&T
SHRI RAM ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .